Huntington Disease
Conditions
Keywords
Huntington Disease, diffusion MRI, diagnosis, fast imaging
Brief summary
The hypotheses of the project are 1. Diffusion MRI using compressed sensing could have reduced motion sensitivity and improved susceptibility related artifact because of accelerated acquisition. 2. The macromolecule deposition in the brain of patients with Huntington Disease (HD) can lead to changes detectible by diffusion MRI. To validate the hypothesis that the new accelerated diffusion MRI technique could produce a new biomarker for HD, patients with Huntington Disease will be recruited. The diffusion index will be calculated using accelerated acquisition. The diagnostic performance will be evaluated for data reconstructed with and without acceleration. The correlation with the disease severity will be assessed.
Detailed description
Diffusion magnetic resonance imaging has emerged as a sensitive, noninvasive tool for assessing the abnormalities in the central nervous system. Applications have been reported in many neurological disorders. However, because of the motion-sensitizing diffusion gradient and the prolonged diffusion encoding time, clinical practice could be difficult especially in patients with motor disorders such as Huntington Disease. Currently there existed no useful biomarker which could reflect either the disease progression or severity of Huntington disease. There is a growing interest in imaging Huntington disease using diffusion magnetic resonance imaging because of its capability to depict the micro-environmental changes. Unfortunately the excessive motor abnormality such as chorea yields the acquisition of diffusion magnetic resonance imaging unfeasible in a clinical setting. The diffusion MRI with compressed sensing demonstrated reduced motion sensitivity and improved susceptibility related artifact because of the accelerated acquisition. Because of the reduced acquisition time, diffusion MRI in patient with Huntington Disease would be possible. It is therefore expected that the macromolecule deposition in the brain of patients with HD can lead to detectible changes in diffusion properties. The accelerated diffusion MRI techniques will be used to acquire data from healthy volunteers and patients with Huntington disease. The aim of the study is to develop and optimize a novel accelerated diffusion Magnetic Resonance Imaging (MRI) technique using advanced compressed sensing techniques. The joint sparsity constraint algorithm will be implemented in an in-line reconstruction platform for the diffusion MRI processing. The second aim is to test the efficiency of the new accelerated diffusion MRI technique from phantom and in healthy human. Finally to validate the hypothesis that the new accelerated diffusion MRI technique could produce a new biomarker for HD, patients with Huntington Disease will be recruited. The diffusion index will be calculated using accelerated acquisition. The diagnostic performance will be evaluated for data reconstructed with and without acceleration. The correlation with the disease severity will be assessed. A risk management report will be concluded at the end of project execution for registration in the department of health. The acceleration diffusion MRI could provide new insight to the etiology of the disease. The in-line image reconstruction platform could be used for pediatric or psychiatric patients who cannot hold still in the scanner for a prolonged period and in patients with movement disorders.
Interventions
None listed
Sponsors
Study design
Eligibility
Inclusion criteria
* Huntington Disease 1. All participants should be aged between 20 and 70 year old. 2. Established diagnosis by a neurological examination and genetic assessment of CAG expansion in the Htt gene. 3. Able to understand and provide signed informed consent. * Healthy Controls: 1. Able to understand and provide signed informed consent 2. age range and gender matched with Patients with HD 3. without significant neuropsychiatric disorders
Exclusion criteria
Human Subjects The participants will be divided into 2 groups: Huntington Disease Group and Healthy Control Group. All participants should be aged between 20 and 70 year old, right handed and gender balanced.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Feasibility study on healthy human. | the 30th month | Procedure: Diffusion MRI will be acquired form healthy volunteers. Approach: Images will be acquired with and without compressed sensing DTI The reproducibility of compressed sensing diffusion MRI will be assessed in human |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Diagnosis Huntington Disease | end of the fourth year | Procedure: 1. Diffusion MRI will be acquired from patients with HD 2. Diagnostic performance will be analyzed when compared to the healthy control in Validation II in a case control study. 3. The correlation with disease severity and the image finding will be examined. Approach 1\. ROI selected from basal ganglia 2. The receiver operative characteristic analysis will be performed and the area under curve will be determined. 3. The disease severity will be assessed by Unified Huntington Disease Scale. The correlation will be assessed by Spearmann's Ranked correlation. |
Countries
Taiwan