Skip to content

Neuromonitoring of Hepatic Encephalopathy

Frontal Electroencephalogram Variables Are Associated With Outcome and Stage of Hepatic Encephalopathy in Acute Liver Failure

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01878305
Enrollment
20
Registered
2013-06-14
Start date
2005-12-31
Completion date
2011-12-31
Last updated
2013-06-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hepatic Encephalopathy, Liver Failure, Acute

Keywords

hepatic encephalopathy, brain waves, electroencephalogram, transcranial Doppler ultrasonography, physiological monitoring, intensive care

Brief summary

Neuromonitoring of critically ill patients in the intensive care unit (ICU) is challenging. Clinical scoring systems produce insufficient information with deeply sedated patients, and disturbances of normal hemostasis limit the use of invasive intra-cranial pressure measurements. EEG based monitoring algorithms have been introduced into the operation theater and general anaesthesia, but these algorithms cannot be used in the intensive care setting without modifications. EEG is also susceptible to electrical disturbances, such as those created by patient movement. The study is conducted in Finland, in the intensive care unit of the Surgical Hospital of Helsinki. The total number of patients in this study is 20, and it is a part of a larger neuromonitoring study with a total of 110 patients. The patients are divided into four subgroups, as follows: 1. patients admitted to ICU with acute liver failure, 2. patients admitted to the postoperative cardio-thoracic ICU after cardiac surgery with perioperative total heart arrest, 3. patients admitted to the ICU because of status epilepticus and finally 4. patients in critical condition, admitted to the ICU after any surgery. This study concentrates on the first group of patients with acute liver failure. Clinical care of patients is not altered. When arriving into the ICU EEG-monitoring will added to routine monitoring. To evaluate the neurological status the following tests are performed: clinical test, blood tests and transcranial doppler ultrasound. The Entropy of EEG is measured along with the raw EEG signal. The recruiting of study patients was begun in December 2005 and the final study patients were recruited in December 2011. GE Healthcare Finland supplies the entropy monitoring devices and pays the salary of the research nurses who collect the study data. Clinical investigators will not receive funding from any commercial company. All patients (or their next of kin) included have given their written informed consent for inclusion in the study. The aim of this study is to find new factors and new non-invasive techniques, which correlate with the neurological state and outcome of patients suffering critical illness.

Interventions

DEVICEMolecular Adsorbent Recirculating System (MARS)

MARS is an extracorporeal albumin dialysis device, used in the treatment of liver failure patients to stabilize the patient and halt the progression of HE, giving the liver time to recover in some cases and allowing additional time before liver transplantation in others.

Sponsors

GE Healthcare
CollaboratorINDUSTRY
University of Helsinki
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* age 18 or over * acute liver failure, referred to the ICU of the Surgical Hospital

Exclusion criteria

\-

Design outcomes

Primary

MeasureTime frame
Number of participants recovering without the need for a liver transplantParticipant will be followed for the duration of their intensive care stay, an expected average of two weeks

Countries

Finland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026