MICHI™ Neuroprotection System (NPS+f) Filter Debris Analysis Study (The F-1 Study)

MICHI™ Neuroprotection System (NPS+f) Filter Debris Analysis Study (The F-1 Study)

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01877174
Enrollment
24
Registered
2013-06-13
Start date
2013-05-31
Completion date
2013-10-31
Last updated
2014-09-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Internal Carotid Artery Stenosis

Keywords

Internal Carotid Stenosis, Reverse Flow, Carotid stenting, MICHI(TM) NPS+f

Brief summary

This study will be conducted in up to 10 hospitals in Europe, up to 75 patients will be enrolled. The purpose of the study is to evaluate any debris that may be captured in the inline filter of the MICHI(TM) Neuroprotection System with Filter (NPS+f) during its use in a transcarotid stenting procedure. The MICHI NPS+f is an embolic protection device that uses reverse flow to protect the brain during stenting of the Internal Carotid Artery. It is CE marked and is used in routine practice for the purpose of this study.

Interventions

DEVICEMICHI(TM) NPS+f

Transcarotid delivery system for carotid stents with flow reversal

PROCEDUREtranscarotid stenting

Sponsors

Silk Road Medical
Lead SponsorINDUSTRY

Study design

Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

Inclusion and

Exclusion criteria

per CE marked Instructions For Use Inclusion Criteria: 1. Adequate central venous access 2. Common carotid artery reference diameter of at least 6 mm 3. Carotid bifurcation is a minimum of 5 cm above the clavicle as measured by duplex Doppler ultrasound (DUS) or computerized axial tomography (CT) angiography or magnetic resonance (MR) angiography

Design outcomes

Primary

MeasureTime frameDescription
Percentage of patients with debris captured in the MICHI(TM) inline filterDuring MICHI(TM) NPS+f procedureThe percentage of patients with any debris captured in the MICHI(TM) inline filter will be calculated

Secondary

MeasureTime frameDescription
Volume of debris captured in the MICHI(TM) inline filterDuring MICHI(TM) NPS+f procedureFor all patients, where debris is captured in the MICHI(TM) inline filter, the volume of debris will be measured
Histological analysis of debris captured in the MICHI(TM) inline filterDuring MICHI(TM) NPS+f procedureFor all patients, where debris is captured in the MICHI(TM) inline filter, the type of plaque will be determined.

Countries

Belgium, Germany, Spain

Outcome results

None listed