Skip to content

Appropriate Laryngeal Mask Airway Size in Patients With Overweight: A Comparison of the Actual Body Weight and Ideal Body Weight

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01843270
Enrollment
100
Registered
2013-04-30
Start date
2013-11-30
Completion date
2014-09-30
Last updated
2014-09-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

General Anesthesia

Keywords

general anesthesia, body weight, laryngeal mask airway size

Brief summary

The classic laryngeal mask airway is one of the keystones of modern anaesthetic practice. It achieves a reliable airway with a low incidence of major complications and pharynges-laryngeal morbidity. The manufactures of laryngeal mask airway recommend the proper size selection by actual body weight. It was recommended a size 3 for 30-70kg, a size 4 for 70-90 kg, and size 5 for \> 90 kg. Obesity increases the fat tissue around an upper airway and decreases the pharyngeal cross sectional area. Also it was reported that pharyngeal area was reduced according to the increasing of BMI. Therefore, the aim of this study is to determine which of actual body weight or ideal body weight is proper on the size selection of laryngeal mask airway.

Interventions

DEVICEactual body weight based size

According randomized allocated group, the laryngeal mask airway is inserted based on actual or ideal body weight-based sizes before the surgery.

DEVICEideal body weight based size

According randomized allocated group, the laryngeal mask airway is inserted based on actual or ideal body weight-based sizes before the surgery.

Sponsors

Yonsei University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
20 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

* age 20\ 70 * body mass index \> 25 kg/m2 * patient who needs surgery with laryngeal mask airway

Exclusion criteria

* difficult airway * upper airway infection or disease of airway * history of gastroesophageal reflux * history of head and neck surgery

Design outcomes

Primary

MeasureTime frameDescription
Oropharyngeal leak pressure10minsOropharyngeal leak pressure is measured when the airway pressure becomes the plateau state in condition of gas flow 3 L/min and flow out valve 30 cmH2O.

Countries

South Korea

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026