Effect of Septal Versus Apical Pacing- a Comparative Study Using Cardiac MRI

Multiparametric CMR Assessment of Apical Versus Septal Pacing Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01842243
Acronym
MAPS
Enrollment
53
Registered
2013-04-29
Start date
2012-02-29
Completion date
2015-12-31
Last updated
2019-02-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ventricular Dysfunction, Ventricular Remodelling

Keywords

Ventricular dysfunction, MRI, Echocardiography, Pacemakers

Brief summary

Despite considerable effort the optimal site to place a pacemaker lead at the time of pacemaker implant remains unclear. Historically pacemaker leads have always been inserted at the bottom (apex) of the heart. It is suggested that a lead placed at the apex is associated with an increase in heart rhythm problems and also heart failure (impaired pumping function). The top of the ventricle (septum) has been investigated as an alternative site and is now routinely used by some centres. Previous estimation of the hearts pumping function (ejection fraction) has been limited to the use of echo (sound waves). Echo is not sensitive enough to detect small changes in the ejection fraction reliably (measure of pumping function of heart). The gold standard for measurement of ejection fraction is MRI (using magnets). Previous pacemakers have not been compatible with MRI scans. The latest generation of pacemakers are now able to be safely scanned within an MRI scanner. This allows a much more accurate estimation of the effects of a pacemaker on the ejection fraction which has not yet been studied. The investigators plan to study those patients undergoing a pacemaker implant and ablation procedure as part of their standard care. Individuals will have an exercise test, blood test used to measure biomarkers and fill in a symptom questionnaire. Individuals will have a Cardiac MR compatible pacemaker fitted and 2 ventricular leads will be inserted, one apically and one septally. Only one lead will be used at any given time. Individuals will then undergo their planned AV node ablation. Following this they will have a cardiac MR scan. Further MRI scans will be performed at 9 and 18 month intervals, as will symptom questionnaires, blood tests (BNP) to determine heart muscle strain, exercise testing and echocardiograms. The hypothesis is that a lead placed on the septum will produce superior cardiac performance over the short and long term.

Interventions

PROCEDUREApical pacing

Pacemaker set to pace at right ventricular apex initially.

PROCEDURESeptal pacing

Pacemaker set to pace at right ventricular septum initially.

DEVICEPacemaker

MR conditional Pacemaker implanted in all study patients

Sponsors

Abbott Medical Devices
CollaboratorINDUSTRY
British Heart Foundation
CollaboratorOTHER
Manchester University NHS Foundation Trust
Lead SponsorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
DIAGNOSTIC
Masking
TRIPLE (Subject, Caregiver, Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

* Patients in permanent Atrial Fibrillation (AF)requiring a pacemaker on clinical grounds (tachycardia/bradycardia syndrome or requiring an AV node ablation)and AV node ablation or a pacemaker for rate control) * Patients aged 18 to 85 years old. * Able to consent for study.

Exclusion criteria

* Patients with moderate to severe LV dysfunction (EF \< 40%). * Any contraindication to an MRI scan. * Patients indicated for an Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy. * Patients with a Myocardial Infarction within three months prior to enrollment. * Patients that received bypass surgery within three months prior to enrollment. * Patients that had a valve replacement within three months prior to enrollment or patients with a mechanical right heart valve. * Patients where a right ventricular lead cannot be placed e.g. complex congenital heart disease. * Patients with hypertrophic obstructive cardiomyopathy. * Patients with acute coronary syndrome, unstable angina, severe mitral regurgitation and/or haemodynamically significant aortic stenosis. * Previous implanted pacemaker or cardioverter defibrillator. * Terminal conditions with a life expectancy of less than two years. * Participation in any other study that would confound the results of this study. * Psychological or emotional problems that may interfere with the volunteer's ability to provide full consent or fully understand the purposes of the study. * Pregnant patients or patients who may become pregnant during the time-scale of the study.

Design outcomes

Primary

MeasureTime frameDescription
Ventricular Ejection fraction18 monthsComparison of % change in Left and Right Ventricular Ejection Fractions between apical and septal pacing groups as measured on MRI.

Secondary

MeasureTime frameDescription
MRI measures of Left and Right ventricular dyssynchrony18 months
Exercise Capacity as measured by CPEX18 months
6 minute walk tests18 months
Quality of life measures SF3618 months
Level of Pro-BNP18 monthsBlood sampling
Levels of BNP18 monthsBlood Sampling
Level of MMP-118 monthsBlood sampling
Level of MMP218 monthsBlood sampling
Level of MMP-918 monthsBlood sampling
Level of Troponin18 monthsBlood sampling
Level of GDF-1518 monthsBlood sampling
Level of ICTP18 monthsBlood sampling