Performance of an Investigational Blood Glucose Monitoring System

Performance of the Ninja 3 Plus Blood Glucose Monitoring System

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01824355
Enrollment
113
Registered
2013-04-04
Start date
2013-03-31
Completion date
2013-03-31
Last updated
2016-02-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes

Brief summary

The purpose of this study was to demonstrate that untrained subjects who have diabetes can operate the Investigational Blood Glucose Monitoring System (BGMS) and obtain valid glucose results.

Interventions

DEVICENinja 3 PLUS Investigational BG Monitoring System

Untrained subjects with diabetes performed self Blood Glucose (BG) tests with capillary fingerstick and palm blood using the Ninja 3 PLUS Investigational BG Monitoring System. Study staff tested subject fingerstick blood. All BG results were compared to a reference laboratory glucose method.

Sponsors

Ascensia Diabetes Care
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Inclusion Criteria: 1. Males and females, 18 years of age or older. 2. People with type 1 or type 2 diabetes. 3. Able to speak, read and understand English. 4. Willing to complete all study procedures. *

Exclusion criteria

1. Hemophilia or any other bleeding disorder. 2. Pregnancy. 3. Physical, visual or neurological impairments that would make the person unable to perform testing with the BGM. 4. Previously participated in a blood glucose monitoring study using the Ninja 3 Plus BGMS. 5. Working for a medical laboratory, hospital or other clinical setting that involves training on or clinical use of blood glucose meters. 6. Working for a competitive medical device company, or having an immediate family member who works for such a company. 7. A condition, which in the opinion of the investigator or designee, would put the person or study conduct at risk.

Design outcomes

Primary

MeasureTime frameDescription
Percent of Self Test Fingerstick Blood Glucose Results Within ±15 mg/dL (< 75 mg/dL) and Within ±20% (≥ 75 mg/dL) of the Laboratory Glucose Method1 hourUntrained subjects with diabetes who self-tested fingerstick blood used the Ninja 3 PLUS investigational Blood Glucose Monitoring System (BGMS). BGMS results were compared with capillary plasma BG results obtained with a reference laboratory glucose method - YSI Life Sciences (YSI) Analyzer. BG meter results were used to calculate the number of BGMS results within +/- 15mg/dL (for reference BG results \<75mg/dL) and within +/- 20% (for reference BG results \>=75mg/dL) of the YSI reference method results.

Secondary

MeasureTime frameDescription
Percent of Self Test Fingerstick Blood Glucose Results Within ±15 mg/dL (< 100 mg/dL) and Within ±15% (≥ 100 mg/dL) of the Laboratory Glucose Method1 hourUntrained subjects with diabetes who self-tested fingerstick blood used the Ninja 3 PLUS investigational Blood Glucose Monitoring System (BGMS). BGMS results were compared with capillary plasma BG results obtained with a reference laboratory glucose method - YSI Life Sciences (YSI) Analyzer. BG meter results were used to calculate the number of BGMS results within +/- 15mg/dL (for reference BG results \<100mg/dL) and within +/- 15% (for reference BG results \>=100mg/dL) of the YSI reference method results.
Percent of Self Test Fingerstick Blood Glucose Results Within ±12.5 mg/dL (< 100 mg/dL) and Within ±12.5% (≥ 100 mg/dL) of the Laboratory Glucose Method1 hourUntrained subjects with diabetes who self-tested fingerstick blood used the Ninja 3 PLUS investigational Blood Glucose Monitoring System (BGMS). BGMS results were compared with capillary plasma BG results obtained with a reference laboratory glucose method - YSI Life Sciences (YSI) Analyzer. BG meter results were used to calculate the number of BGMS results within +/- 12.5mg/dL (for reference BG results \<100mg/dL) and within +/- 12.5% (for reference BG results \>=100mg/dL) of the YSI reference method results.
Percent of Blood Glucose Results From Alternative Site Testing (AST) of the Palm Within ±15 mg/dL (< 75 mg/dL) and Within ±20% (≥ 75 mg/dL) of the Laboratory Method.1 hourUntrained subjects with diabetes self-tested Alternative Site (AST) Palm blood using the Ninja 3 PLUS investigational Blood Glucose Monitoring System (BGMS). BGMS AST results were compared with capillary plasma BG results obtained with a reference laboratory glucose method - YSI Life Sciences (YSI) Analyzer. BG meter results were used to calculate the number of AST BGMS results within +/- 15mg/dL (\<75mg/dL YSI capillary plasma) and within +/- 15% (\>=75mg/dL YSI capillary plasma).
Percent of Fingerstick Blood Glucose Results Within ±15 mg/dL (< 75 mg/dL) and Within ±20% (≥ 75 mg/dL) of the Laboratory Glucose Method When Tested by Study Staffone hourStudy Staff tested subject fingerstick blood using the Ninja 3 PLUS investigational Blood Glucose Monitoring System (BGMS). BGMS results were compared with capillary plasma BG results obtained with a reference laboratory glucose method - YSI Life Sciences (YSI) Analyzer. BG meter results were used to calculate the number of BGMS results within +/- 15mg/dL (for reference BG results \<75mg/dL) and within +/- 20% (for reference BG results \>=75mg/dL) of the YSI reference method results.
Number of Subject Responses That 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire Statements1 hourStaff obtained subject responses using short questionnaires to provide feedback on instructions for use and the basic operation of the BGMS. Subjects could respond 'Strongly Agree' 'Agree' 'Neutral' 'Disagree' or 'Strongly Disagree.'

Countries

United States

Participant flow

Participants by arm

ArmCount
Intended Users of the Monitoring System
Untrained subjects with diabetes used the Ninja 3 PLUS Investigational BG Monitoring System. Ninja 3 PLUS Investigational BG Monitoring System: Untrained subjects with diabetes performed self Blood Glucose (BG) tests with capillary fingerstick and palm blood using the Ninja 3 PLUS Investigational BG Monitoring System. Study staff tested subject fingerstick blood. All BG results were compared to a reference laboratory glucose method.
113
Total113

Withdrawals & dropouts

PeriodReasonFG000
Overall StudyAdverse Event2
Overall Studyunevaluable reference method results per1

Baseline characteristics

CharacteristicIntended Users of the Monitoring System
Age, Customized
Age of enrolled subjects
59.1 years
Ethnicity (NIH/OMB)
Hispanic or Latino
10 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
103 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
American Indian or Alaska Native
1 responses
Race (NIH/OMB)
Asian
0 responses
Race (NIH/OMB)
Black or African American
26 responses
Race (NIH/OMB)
More than one race
1 responses
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 responses
Race (NIH/OMB)
Unknown or Not Reported
3 responses
Race (NIH/OMB)
White
84 responses
Region of Enrollment
United States
113 participants
Sex: Female, Male
Female
63 Participants
Sex: Female, Male
Male
50 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
— / —
other
Total, other adverse events
3 / 113
serious
Total, serious adverse events
0 / 113

Outcome results

Primary

Percent of Self Test Fingerstick Blood Glucose Results Within ±15 mg/dL (< 75 mg/dL) and Within ±20% (≥ 75 mg/dL) of the Laboratory Glucose Method

Untrained subjects with diabetes who self-tested fingerstick blood used the Ninja 3 PLUS investigational Blood Glucose Monitoring System (BGMS). BGMS results were compared with capillary plasma BG results obtained with a reference laboratory glucose method - YSI Life Sciences (YSI) Analyzer. BG meter results were used to calculate the number of BGMS results within +/- 15mg/dL (for reference BG results \<75mg/dL) and within +/- 20% (for reference BG results \>=75mg/dL) of the YSI reference method results.

Time frame: 1 hour

Population: 220 Blood Glucose results were analyzed. Each subject who completed (110 subjects) the study provided 2 Blood Glucose test results.

ArmMeasureValue (NUMBER)
Intended Users of the Monitoring SystemPercent of Self Test Fingerstick Blood Glucose Results Within ±15 mg/dL (< 75 mg/dL) and Within ±20% (≥ 75 mg/dL) of the Laboratory Glucose Method99.09 percentage of BG results
Secondary

Number of Subject Responses That 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire Statements

Staff obtained subject responses using short questionnaires to provide feedback on instructions for use and the basic operation of the BGMS. Subjects could respond 'Strongly Agree' 'Agree' 'Neutral' 'Disagree' or 'Strongly Disagree.'

Time frame: 1 hour

Population: Four subjects of those enrolled (113 subjects) had either missing or unevaluable questionnaire data.

ArmMeasureGroupValue (NUMBER)
Intended Users of the Monitoring SystemNumber of Subject Responses That 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire StatementsI find it easy to do a blood test with this meter108 participants
Intended Users of the Monitoring SystemNumber of Subject Responses That 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire StatementsThe meter display is easy to see and read108 participants
Intended Users of the Monitoring SystemNumber of Subject Responses That 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire StatementsIt was easy to understand my test results108 participants
Intended Users of the Monitoring SystemNumber of Subject Responses That 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire StatementsI like the overall meter design106 participants
Intended Users of the Monitoring SystemNumber of Subject Responses That 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire StatementsI find the meter easy to use106 participants
Intended Users of the Monitoring SystemNumber of Subject Responses That 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire StatementsThe instructions (User Guide) easy to understand105 participants
Intended Users of the Monitoring SystemNumber of Subject Responses That 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire StatementsInstructions clearly explain how to run a test107 participants
Intended Users of the Monitoring SystemNumber of Subject Responses That 'Strongly Agree' or 'Agree' or Are 'Neutral' With Questionnaire StatementsInstructions clearly explain meter error messages108 participants
Secondary

Percent of Blood Glucose Results From Alternative Site Testing (AST) of the Palm Within ±15 mg/dL (< 75 mg/dL) and Within ±20% (≥ 75 mg/dL) of the Laboratory Method.

Untrained subjects with diabetes self-tested Alternative Site (AST) Palm blood using the Ninja 3 PLUS investigational Blood Glucose Monitoring System (BGMS). BGMS AST results were compared with capillary plasma BG results obtained with a reference laboratory glucose method - YSI Life Sciences (YSI) Analyzer. BG meter results were used to calculate the number of AST BGMS results within +/- 15mg/dL (\<75mg/dL YSI capillary plasma) and within +/- 15% (\>=75mg/dL YSI capillary plasma).

Time frame: 1 hour

Population: 209 (220-11) Blood Glucose results were analyzed. 2 subjects had low blood sugar and per protocol their 4 AST BG results were not evaluable. 3 BG results were excluded as they were protocol deviations. One subject (2 BG results) did not complete testing within protocol timeframe and one subject (2 BG results) was unable to obtain AST blood.

ArmMeasureValue (NUMBER)
Intended Users of the Monitoring SystemPercent of Blood Glucose Results From Alternative Site Testing (AST) of the Palm Within ±15 mg/dL (< 75 mg/dL) and Within ±20% (≥ 75 mg/dL) of the Laboratory Method.97.13 percentage of AST Blood Glucose Results
Secondary

Percent of Fingerstick Blood Glucose Results Within ±15 mg/dL (< 75 mg/dL) and Within ±20% (≥ 75 mg/dL) of the Laboratory Glucose Method When Tested by Study Staff

Study Staff tested subject fingerstick blood using the Ninja 3 PLUS investigational Blood Glucose Monitoring System (BGMS). BGMS results were compared with capillary plasma BG results obtained with a reference laboratory glucose method - YSI Life Sciences (YSI) Analyzer. BG meter results were used to calculate the number of BGMS results within +/- 15mg/dL (for reference BG results \<75mg/dL) and within +/- 20% (for reference BG results \>=75mg/dL) of the YSI reference method results.

Time frame: one hour

Population: 220 Blood Glucose results were analyzed. Study Staff provided 2 Blood Glucose Test Results from each subject who completed (110 subjects) the study.

ArmMeasureValue (NUMBER)
Intended Users of the Monitoring SystemPercent of Fingerstick Blood Glucose Results Within ±15 mg/dL (< 75 mg/dL) and Within ±20% (≥ 75 mg/dL) of the Laboratory Glucose Method When Tested by Study Staff100.0 percentage of Blood Glucose Results
Secondary

Percent of Self Test Fingerstick Blood Glucose Results Within ±12.5 mg/dL (< 100 mg/dL) and Within ±12.5% (≥ 100 mg/dL) of the Laboratory Glucose Method

Untrained subjects with diabetes who self-tested fingerstick blood used the Ninja 3 PLUS investigational Blood Glucose Monitoring System (BGMS). BGMS results were compared with capillary plasma BG results obtained with a reference laboratory glucose method - YSI Life Sciences (YSI) Analyzer. BG meter results were used to calculate the number of BGMS results within +/- 12.5mg/dL (for reference BG results \<100mg/dL) and within +/- 12.5% (for reference BG results \>=100mg/dL) of the YSI reference method results.

Time frame: 1 hour

Population: 220 Blood Glucose results were analyzed. Each subject who completed (110 subjects) the study provided 2 Blood Glucose test results.

ArmMeasureValue (NUMBER)
Intended Users of the Monitoring SystemPercent of Self Test Fingerstick Blood Glucose Results Within ±12.5 mg/dL (< 100 mg/dL) and Within ±12.5% (≥ 100 mg/dL) of the Laboratory Glucose Method93.64 percentage of Blood Glucose Results
Secondary

Percent of Self Test Fingerstick Blood Glucose Results Within ±15 mg/dL (< 100 mg/dL) and Within ±15% (≥ 100 mg/dL) of the Laboratory Glucose Method

Untrained subjects with diabetes who self-tested fingerstick blood used the Ninja 3 PLUS investigational Blood Glucose Monitoring System (BGMS). BGMS results were compared with capillary plasma BG results obtained with a reference laboratory glucose method - YSI Life Sciences (YSI) Analyzer. BG meter results were used to calculate the number of BGMS results within +/- 15mg/dL (for reference BG results \<100mg/dL) and within +/- 15% (for reference BG results \>=100mg/dL) of the YSI reference method results.

Time frame: 1 hour

Population: 220 Blood Glucose results were analyzed. Each subject who completed (110 subjects) the study provided 2 Blood Glucose test results.

ArmMeasureValue (NUMBER)
Intended Users of the Monitoring SystemPercent of Self Test Fingerstick Blood Glucose Results Within ±15 mg/dL (< 100 mg/dL) and Within ±15% (≥ 100 mg/dL) of the Laboratory Glucose Method97.73 percentage of Blood Glucose Results

Source: ClinicalTrials.gov · Data processed: Feb 19, 2026