Asthma and Quantifying Delivery Of Radio Labeled Aerosol

Quantifying Delivery Of Radio Labeled Aerosol During Noninvasive Ventilation To Stable Moderate And Severe Asthmatics: A Randomized, Cross-Over Clinical Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01823926
Enrollment
13
Registered
2013-04-04
Start date
2011-10-31
Completion date
2012-08-31
Last updated
2013-04-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Asthma

Keywords

vibrating mesh nebulizers, noninvasive ventilation, residual volume, pulmonary scintigraphy, radioaerosol, nebulization.

Brief summary

Introduction: Inhalation therapy has been established as an efficient route to treat asthma exacerbations, but coupled to noninvasive ventilation (NIV) remains quite challenging. Objectives: The aim of this study were to compare radiaoaerosol pulmonary index and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) using vibrating mesh nebulizers (VMN) and jet nebulizer (JN) coupled to noninvasive ventilation (NIV). Material and methods: The investigators assessed 10 stable moderate to severe asthmatics in a crossover study. Patients was randomly assigned to participate in both phases of the study: Phase 1(NIV+MN) and phase 2(NIV+JN). DTPA-Tc99m with radioactivity of 25 miC was used to inhaler using JN positioned in the circuit using a T piece, particle size generation in a five micron range and oxygen flow tritated at eight L/min and MN was positioned in the mask, particle size generation in a one range and connected to electrical energy. NIV was used a bilevel pressure through a face mask attached with straps and pressure adjusted were 12 cmH2O and 5 cmH2O as inspiratory and expiratory pressures, respectively. After, radioactivity counts were performed using a gama camera and regions of interest were delimited. To calculate aerosol mass balance the investigators considered the amount of radioaerosol deposited into the lungs, upper airways, stomach, nebulizer, circuit, inspiratory and expiratory filters, and mask divided for each of these compartments and represented as a percentage.

Interventions

OTHERNoninvasive ventilation

Bilevel positive pressure (BiPAP Synchrony, Respironics®, Murrysville, Pennsylvania, USA) was applied through face mask (Comfort Full 2, Respironics®, Murrysville, Pennsylvania, USA) attached with straps and pressure adjusted were 12 cmH2O of inspiratory pressure and 5 cmH2O of expiratory pressure at the beginning of the procedure (França et al., 2006).

Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and 3 mL of saline solution was added to complete 3 Ml. JN (Mist yMax, Air Life, Yorba Linda, USA) was positioned in the circuit using a T piece, particle size generation in a 5 µm range (according to the manufacturer information) and flow oxygen tritated at 8 L/min.

DEVICEThe vibrating mesh nebulizer (VMN)

Both nebulizers were charged with 2.5 mg of salbutamol and 0.25 mg of ipratropium bromide and 3 mL of saline solution was added to complete 3 Ml. VMN (Aeroneb Solo, Galway, Ireland) was positioned in the mask using an elbow (Elbow Kit, Respironics®, Murrysville, Pennsylvania, USA), particle size generation in a 1 µm and connected to electrical energy.

Sponsors

Universidade Federal de Pernambuco
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
No

Inclusion criteria

* stable moderate to severe asthma (FEV1 \> 60% and \> 80% and PEF with a variation of 30% from the predicted values to moderate and FVE1 \> 60% and ); * More than one year elapsed since the diagnosis of asthma; * None exacerbation in the last six months; * Age between 18 - 60 years, from both sexes, * Able to understand verbal commands * Consent to participate in this protocol.

Exclusion criteria

* presence of dyspnea; * smoking history; * cardiopulmonary diseases (chronic obstructive pulmonary disease, pneumonia, cardiac failure, myocardial infarction, pneumothorax); * hyperthermia; * hemodynamic instability (heart rate \> 150 bpm and systolic blood pressure \< 90 mmHg); * arrhythmia absence; * pregnancy * contraindications for use of noninvasive ventilation

Design outcomes

Primary

MeasureTime frameDescription
To compare inhaled dose of radioaerosol into the lungs and determine distribution across horizontal and vertical gradients10 mouthsImmediately after inhalation, participants sat in a chair with the back positioned in front to the gamma camera (STARCAM 3200 GE, California, USA) to obtain radioactives counts from the posterior thorax during a period of 500 seconds on a matrix of 256 X 256 matrix. After, participants were positioned sitting in front to the gama camera to obtain images from face. Then, the same procedure was performed to analysis deposition in the nebulizer, circuits, inspiratory filter, expiratory filter and face mask. Counts representing stomach were obtained from posterior thorax and corrections for decay of technetium were used to during extrapulmonary measurements.

Secondary

MeasureTime frameDescription
To quantify mass balance of the delivery system and different compartments, including intrapulmonary and extrapulmonary deposition.10 mouthsThe analysis of deposition in pulmonary and extrapulmonary compartments was expressed as a percentage from the count in each compartment to the total radioaerosol mass generated by nebulizers. The inhaled radioaerosol was considered the sum of deposition into the upper airways, lungs and stomach.

Countries

Brazil

Outcome results

None listed