Bronchial Cuff Volume at Air-tight Seal, Intracuff Cuff Pressure at Air-tighe Seal
Conditions
Brief summary
The purpose of this study is to investigate the appropriate window setting of chest computed tomography to select a correct size of double-lumen endobronchial tube.
Interventions
Double-lumen tube size is selected according to the internal diameter of the left mainstem bronchus measured in the chest computed tomography with width 1000 HU and level -450 HU.
Double-lumen tube size is selected according to the internal diameter of the left mainstem bronchus measured in the chest computed tomography with width 400 HU and level 25 HU.
Sponsors
Study design
Eligibility
Inclusion criteria
* Patients undergoing thoracic surgery that require the placement of left-sided double-lumen tubes
Exclusion criteria
* Abnoraml anatomy of tracheobronchail tree * Intraluminal lesion in the left mainstem bronchus * Anticipated difficult intubation
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Air-leak at deflation of bronchial cuff | An expected average of 10 min after double lumen tube intubation |
| Air-tight seal below resting volume of bronchial cuff | An expected average of 10 min after double lumen tube intubation |
Countries
South Korea