Skip to content

Trial Comparing 19 and 25G Needles for Fine Needle Aspiration (FNA) of Solid Pancreatic Mass Lesions Greater Than 35mm

Randomized Trial Comparing 19 and 25G Needles for Fine Needle Aspiration (FNA) of Solid Pancreatic Mass Lesions Greater Than 35mm

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01815606
Enrollment
51
Registered
2013-03-21
Start date
2013-02-28
Completion date
2013-12-31
Last updated
2017-08-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pancreatic Cancer

Keywords

Pancreas, cancer, EUS-FNA, 19Gauge, 25Gauge, 35mm mass

Brief summary

This study will test two different needles for performing a biopsy of the pancreas during endoscopic ultrasound (EUS) procedures. Patients who are asked to participate in this study have a growth in the pancreas measuring greater than 35mm that needs a biopsy so that a diagnosis can be made. The biopsy can be performed using either a 19 or 25-Gauge needle. The purpose of this study is to compare which of the two needles is better for performing biopsies of the pancreas on masses that are greater than 35mm.

Detailed description

Endoscopic Ultrasound-guided fine needle aspiration (EUS-FNA) can be performed using the 25, 22 or 19 gauge (G) needles. Randomized trials have shown that all three needles are safe and perform equally well. However, in a retrospective study, the diagnostic sensitivity of EUS-FNA for pancreatic masses that measured more than 35mm was less compared to smaller size masses. This is because larger size tumors have more necrosis and it is difficult to identify cancer cells in them to make a diagnosis. Therefore, more biopsies must be performed in larger size tumors to establish a diagnosis. In previous studies it has been shown that the larger 19G needles procure larger and better quality tissue. Therefore, our hypothesis is that, when a larger 19G needle is used to FNA tumors more than 35mm, a diagnosis can be achieved with fewer passes.

Interventions

PROCEDUREbiopsy with 19 gauge needle

biopsy with 19 gauge needle

PROCEDUREbiopsy with 25 gauge needle

biopsy with 25 gauge needle

Sponsors

AdventHealth
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
19 Years to 89 Years
Healthy volunteers
No

Inclusion criteria

All patients referred to Florida Hospital Endoscopy Unit for assessment of pancreatic mass lesions greater than 35 mm on computed tomography (CT) that require FNA.

Exclusion criteria

* Age \< 19 years * Unable to safely undergo EUS for any reason * Coagulopathy (INR \>1.6, Prothrombin Time \>18secs, Thrombocytopenia \<80,000 cells/ml) * Unable to consent * Non-English speaking patients * Participation in any other clinical trial (excluding registries or databases)

Design outcomes

Primary

MeasureTime frameDescription
Number of passesUp to 12 monthsThe use of a 19G FNA needle reduces the number of passes required to establish a diagnosis in pancreatic tumors that are greater than 35mm in size. This translates to less sedation, faster patient recovery, better safety and time efficiency.

Secondary

MeasureTime frameDescription
Rate of ComplicationUp to 12 monthsTo compare the rate of complications associated with the 19G and 25G needles when sampling pancreatic tumors greater than 35mm in size. Also, the rate of needle dysfunction will be compared. Needle dysfunction is defined as, the need to use more than one needle per pancreatic tumor in an individual patient.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026