Impact of Reconstruction Method (ASIR, FBP) Used in CT on Bone SPECT/CT Image Quality

Impact of Reconstruction Method (Adaptive Statistical Iterative Reconstruction, Filtered Back Projection) Used in Computed Tomography on Bone Single-Photon- Emission-Computed-Tomography/Computed-Tomography Image Quality

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01800084
Acronym
AsirTest
Enrollment
75
Registered
2013-02-27
Start date
2013-08-31
Completion date
2014-05-28
Last updated
2025-11-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

SPECT-CT

Keywords

ASIR, image acquisition, FBP

Brief summary

The main objective of this study is to demonstrate the non-inferiority of SPECT image quality (as measured by the signal / noise ratio) obtained by ASIR reconstruction of very-low-dose CT acquisitions versus the quality of those obtained by filtered back projection (FBP) of low-dose CT acquisitions. The lower limit of non-inferiority is set to -1, the average SPECT signal / noise ratio TEMP expected is between 5 and 6.

Detailed description

The secondary objectives of this study are: A. Demonstrate the non-inferiority of image quality (as assessed by a Likert scale) obtained by ASIR-reconstruction-SPECT versus FBP-reconstruction (the lower-limit of non-inferiority is set at -0.5); B. Verify the non-inferiority of image quality (as measured by the signal / noise ratio)of CT images obtained by ASIR-reconstruction versus FBP-reconstruction (the lower-limit of non-inferiority is set at -0.2); C. Verify the non-inferiority of image quality (as assessed by the Likert scale) of CT images obtained by ASIR-reconstruction versus FBP-reconstruction (the lower limit of non-inferiority is set at -0.5); D. Check that the irradiation dose received by the patient is lower for the acquisition of images reconstructed with ASIR than for the acquisition of images reconstructed with FBP. E. Check the concordance of two evaluations of image quality (Likert scale) made by nuclear medicine physicians (blinded to each other).

Interventions

DEVICEAsir Image Acquisition

In addition to their normal image acquisition, a supplementary image acquisition lasting approximately 20 seconds (i.e. an ASIR image acquisition) will be carried out for each patient.

Sponsors

Centre Hospitalier Universitaire de Nīmes
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* The patient must have given his/her informed and signed consent * The patient must be insured or beneficiary of a health insurance plan * A SPECT-CT exam is scheduled for the patient * The patient is able to withstand an extended position with the arms behind the head for 15 minutes (i.e. patient is able to undergo a SPECT-CT exam)

Exclusion criteria

* The patient is participating in another study * The patient is in an exclusion period determined by a previous study * The patient is under judicial protection, or any kind of guardianship * The patient refuses to sign the consent * The patient has a contra-indication for a treatment necessary for this study (patient is not able to withstand an extended position with the arms behind the head for 15 minutes) * It is impossible to correctly inform the patient * The patient is pregnant, parturient, or breastfeeding * Emergency situations * Presence of osteosynthesis material (or any other material that would generate an artifact during SPECT-CT) in the spine * Patient behaviour hampers image acquisition

Design outcomes

Primary

MeasureTime frameDescription
Spect signal (kBq)2 hours after inclusion (during SPECT-CT scan)The Spect signal is measure on a 1 cm\^3 zone of vertebrae L3.
Spect noise (kBq)2 hours after inclusion (during SPECT-CT scan)The spect noise is carried out on a 1 cm\^3 zone of the aorta

Secondary

MeasureTime frameDescription
Ratio of CT signal / CT noise2 hours after inclusion (during SPECT-CT scan)
Spect image quality Likert scale ranging from 1 to 5, Evaluation n°12 hours after inclusion (during SPECT-CT scan)
CT image quality Likert scale ranging from 1 to 5, Evaluation n°22 hours after inclusion (during SPECT-CT scan)
CT signal (HU)2 hours after inclusion (during SPECT-CT scan)measured on a 1 cm\^3 zone of the aorta
Spect image quality Likert scale ranging from 1 to 5, Evaluation n°22 hours after inclusion (during SPECT-CT scan)
CT image quality Likert scale ranging from 1 to 5, Evaluation n°12 hours after inclusion (during SPECT-CT scan)
Radiation dose (mSv)2 hours after inclusion (during SPECT-CT scan)
CT noise (HU)2 hours after inclusion (during SPECT-CT scan)measured on a 1 cm\^3 zone of the aorta