Skip to content

Assessment of Distal Limbs Fractures With Cone-Beam CT Newtom 5G

Assessment of Distal Limbs Fractures With Cone-Beam CT Newtom 5G

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01796600
Acronym
FRADICOBE
Enrollment
43
Registered
2013-02-22
Start date
2012-07-31
Completion date
2013-06-30
Last updated
2025-09-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Distal Limbs Bones Fractures

Keywords

distal limbs fracture, acute trauma, imaging, cone beam computed tomography,

Brief summary

ConeBeam scanner (CBCT) is a widely technique used for dental and maxillofacial imaging. Patients can be set up in a sitting or a laying position in the, Newtom 5G CBCT allowing for an analysis of the distal appendicular skeleton. The investigators' hypothesis is that the cone-beam scanner could detect and characterize fractures of the extremities similarly to a multidetector CT (MDCT). 150 patients over 18 years requiring a CT scan for a suspected distal limb fracture or a preoperative assessment will be enrolled. The primary endpointis based on the ability of cone-beam scanner to properly characterize the type of fracture using a classification derived from Maurice E. Müller (AO) classification. Secondary endpoints will concern the depiction of the fracture, the assessment of the soft tissues near the fracture, quality of images, inter and intra-operator reproducibility and tolerance of the patient for the examination. Patients will have a MDCT considered as the reference exam, then a CBCT. Exams will be anonymized and read twice by two trained radiologists with 3-6 week intervals. The inter-observer agreement for the diagnosis of fracture type between the two techniques will be evaluated by a kappa coefficient. The evaluation of diagnostic performance will be achieved by studying the sensitivity, specificity, negative predictive value and positive predictive value, and its likelihood ratio. Kappa test will be performed to evaluate the consistency of the characterization of the fracture and the evaluation of soft tissue near the fracture. A Student t test will be performed for paired data if distributions are normal, a Wilcoxon test if not. To assess patient's tolerance, the percentages of (painful, not painful) will be calculated for each technique and will be compared using the Chi2 test (or Fisher's exact test if the chi can not apply).

Interventions

DEVICEThe patients will have a conventional scanner, a reference examination, and a cone-beam scanner Newtom 5G just after the conventional scanner

Sponsors

Hospices Civils de Lyon
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient age 18 years old or above, weight ≤ 160 Kg * Patient require MDCT for a suspected distal limb fracture or a preoperative assessment * French spoken an read * Free and informed consent signed * Being affiliated to a French social security system or similar.

Exclusion criteria

* Patients already included in the study for a previous fracture * Patient with severe pain and reduced spontaneous mobility that could prevent proper positioning for the cone-beam * Lack of effective contraception (risk of pregnancy) or pregnancy proven data on interrogations * Patient on protection of the court, under supervision or trusteeship * Inability to express a consent * Patients already enrolled in a study with a conflict of interest with this study. * The presence of osteosynthesis materiel or capital may interfere with image quality. A sample of 3 to 5 patients may be included at the beginning of the study to test the image quality in presence of material.

Design outcomes

Primary

MeasureTime frame
Characterization of the type of fracture using a classification derived from Maurice E. Müller (AO) classificationFrom the day of the trauma for acute injuries to the first weeks when an occult fracture is suspected

Secondary

MeasureTime frameDescription
Assessment of soft tissues peripheral to the fractureBaseline only, the day the scanner is performed.Articular fluid, hematoma, tendinous or ligamentous lesions
Image quality (for CBCT and MDCT)Baseline only, the day the scanner is performed0 - Insufficient, 1 - Poor, 2 - Average, 3 - Good, 4 - Excellent
Tolerability and duration of the exam (for CBCT and MDCT)Baseline only, the day the scanner is performedPerfect, tolerable, hardly tolerable, intolerable
Duration of the exam (for CBCT and MDCT)Baseline only, the day the scanner is performedPerfect, tolerable, hardly tolerable, intolerable
Inter-intra-observer reproducibilityBseline only, the scanner is performed.2 readings for each operator, with consensus reading for disagreements

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026