Skip to content

Intracranial Hypertension and Optic Nerve Sheath Diameter

Intracranial Hypertension Detection Using Optic Nerve Sheath Diameter Measurement in Children

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01796015
Acronym
DENO
Enrollment
230
Registered
2013-02-21
Start date
2011-04-30
Completion date
2017-02-28
Last updated
2025-09-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cerebral Stroke, Cerebral Venous Thrombosis

Keywords

paediatrics, optic nerve sheath diameter, ultrasound

Brief summary

Intracranial hypertension (ICH) is a mortality risk factor in severe traumatic brain injury (TBI), in purulent meningitis, in hepatic encephalopathy and in Reye's syndrome. It is also a risk factor for severe neurologic sequelae in survivors. Intracranial pressure (ICP) monitoring is likely to guide therapeutics, and certain research on adults or on children, suggest that IH therapeutic approach, for instance for bacterial meningitis, would improve the prognosis. Two monitoring techniques are currently recommended. They are reference methods for ICP measure : * monitoring with intraventricular catheter, * intra-parenchymal monitoring using optical fiber catheter. Non invasive methods have been suggested, including ultrasound measurement of optic nerve sheath diameter (ONSD) which is the most interesting one. The ONSD measured ultrasonically is correlated with ICP level in adults with severe TBI. A diameter over 5,9 mm predicts ICH within the first 24 hours. In children, ONSD average values have been worked out, and an ONSD increase is found in children suffering from hydrocephalus with IH and in children with TBI. ICH precocious detection is fundamental in children sensitive to ICH because their cerebral development is not finished yet. Difficulties met for ICP monitoring implementation in infants and its invasive nature are often disliked by clinicians. A non-invasive exam is then essential to allow a better care of children with ICH in intensive care unit.

Interventions

OTHERONSD ultrasound

Description of the ONSD ultrasound: ONSD is measured 3 mm behind the globe and perpendicularly to the optic nerve axis (2 dimensions mode). For each optic nerve, 2 measures are performed: 1 sagittal and 1 transverse. The patient is positioned in 30° dorsal elevation. Gel is applied on the eyelid and a 7,5 MHz probe is used. At the same time and on the same side, a transcranial Doppler is performed using a 2 MHz probe placed on the temple. Are measured: systolic velocity, mean velocity, diastolic velocity, resistance index and pulsatility index. As ONSD measures cannot be done blinded (regarding ICP monitoring), a centralised evaluation (by 2 experts) of the recorded sonograms is planned.

Sponsors

Hospices Civils de Lyon
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
2 Months to 16 Years
Healthy volunteers
No

Inclusion criteria

For the 97 patients: * children from 2 months to 16 years * in the intensive care unit * TBI : moderate (GCS between 9 and 12) to severe (GCS \<9), whatever the mechanism involved * informed consent form signed by parents Non inclusion Criteria: * obesity (BMI \> 97th percentile for the age) * patient already under replacement therapy. * patient taking AEDs * patient with long-term systemic corticosteroid therapy * history of neurological disease or learning difficulties * no covered by a national health insurance

Design outcomes

Primary

MeasureTime frameDescription
Primary (sensitivity and specificity of echographic measurement of ONSD)To determine diagnostic performance (sensitivity and specificity) of ICH thanks to ultrasound measurement of ONSD, (15 minutes ,before invasive ICP monitoring)Sensitivity and specificity of echographic measurement of the ONSD (mean value of both eyes), taken 15 minutes ,before invasive ICP monitoring, regarding detection of ICH in children with neurological injury, as compared to reference method for ICH detection (ICP monitoring with intraventricular catheter).

Secondary

MeasureTime frameDescription
Secondary outcome (1. To draw learning curves before the study begins to find out the number of ultrasound measurement needed)1. To draw learning curves before the study begins to find out the number of ultrasound measurement needed (day 0)* value (mm) of the echographic ONSD measurement performed by the clinicians/interns (learning curve) compared to the value found by the trainer * mean value, standard deviation and quartiles of ONSD measures performed in a population of patients intubated, ventilated, sedated and without cerebral lesion (control group) * Correlation between echographic ONSD values (mean of the values) and invasive ICP monitoring values (taken same day) * Correlation between variations of ONSD measures and treatment effet on ICH * Comparison of diagnostic capacity of ONSD measurements depending on age, ICH etiology (bacterial meningitis, encephalitis meningitis, stroke, cerebral cerebral thrombophlebitis, TBI and patients from neurosurgery) * determine diagnostic capacity of the measures performed with transcranial Doppler (resistance index, pulsatility index, systolic, mean and diastolic velocities) in the different pathologies and compare them to ONSD values

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026