Skip to content

Acetabular Shell Positioning Using Patient Specific Instruments

Comparison of Acetabular Shell Position Using Patient Specific Instruments vs. Standard Surgical Instruments: A Randomized Clinical Trial

Status
Completed
Phases
Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01791738
Enrollment
36
Registered
2013-02-15
Start date
2011-01-31
Completion date
2012-04-30
Last updated
2015-07-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Avascular Necrosis, Osteoarthritis, Hip, Rheumatoid Arthritis

Keywords

Total Hip Arthroplasty (THA), Patient-Specific Instruments, Acetabular Cup Placement, Accuracy

Brief summary

The proposed study is a double-blinded randomized controlled trial comparing patient specific instruments with solely standardized instruments and pre-operative planning used for the placement of the acetabular cup prosthesis used in total hip arthroplasty. The investigators will enroll 36 patients who have consented to total hip arthroplasty for treatment of hip pathology. This treatment is a standard of care. Patients will receive standard of care pre- and post-operative care and placement of standard of care implants all of which are commercially available and FDA approved for general use for the clinical indications used in these patients. All patients will receive a pre-operative CT scan for surgical planning and comparison with post-operative CT scan. The difference in intervention between the groups will be the creation and use of patient specific instruments from the pre-operative planning session. These instruments will be used for placement of an indexing peripheral guide wire to direct acetabular preparation and placement of the shell assisting standard surgical instruments. Print-offs from the pre-operative plan will also be used in the treatment group. The post-operative scan will be performed within two weeks of the surgery for both the treatment and control groups. The investigators will analyze the difference in acetabular shell placement (acetabular version and abduction angle) from the pre-operatively planned CT scan. These differences will be compared between the control and experimental groups.

Detailed description

No further details to report.

Interventions

PROCEDUREAcetabular positioning system

Pre-operative planning through 3D software with design and fabrication of patient specific instruments for placement of a guide pin to be used to aid in bone preparation for insertion of an acetabular cup in total hip arthroplasty

Sponsors

The Cleveland Clinic
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

Subjects to be included in this protocol will be adult males and females of all races and socioeconomic status meeting the following criteria: * Primary, unilateral direct lateral or posterior THA * 18 to 85 years old at time of surgery * Able to get a pre- and post-operative CT scan at the Cleveland Clinic

Exclusion criteria

* The following criteria will exclude subjects from this protocol: * Significant metal in the joint that results in metal artifact on the pre--operative CT scan, thereby compromising the ability to visualize the acetabulum on the pre-operative simulator. * Pregnancy * Incarceration * Condition deemed by physician or medical staff to be non-conducive to patient's ability to complete the study, or a potential risk to the patient's health and well-being.

Design outcomes

Primary

MeasureTime frame
Difference between planned and actual values of Abduction and Version.Through 2 weeks after surgery.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026