Skip to content

A Comparison of the Blom Low Profile Voice Inner Cannula and the Passy-Muir One-Way Tracheotomy Tube Speaking Valve on Voice Production, Speech Intelligibility, and Biomechanical Swallowing Behavior

A Comparison of the Blom Low Profile Voice Inner Cannula and the Passy-Muir One-Way Tracheotomy Tube Speaking Valve on Voice Production, Speech Intelligibility, and Biomechanical Swallowing Behavior

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01784224
Enrollment
30
Registered
2013-02-05
Start date
2013-01-31
Completion date
2013-10-31
Last updated
2014-06-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mechanical Complication of Tracheostomy

Brief summary

The main purpose of this study is to investigate voice production, speech intelligibility and routine physiologic parameters associated with the Blom low profile voice inner cannula and the Passy-Muir one-way tracheotomy tube speaking valves. Additionally, the purpose of this study is to investigate the effects (if any) associated with the Blom low profile voice inner cannula and the Passy-Muir one-way tracheotomy tube speaking valves on swallowing behavior and biomechanical movement of the hyolaryngeal complex during routine diagnostic modified barium swallowing evaluations.

Detailed description

The goal of a one-way tracheotomy tube speaking valve is to allow cognitively intact individuals who require a tracheotomy tube communicate with their own voice. All non-verbal communication strategies have shortcomings. Lip reading is unreliable, communication boards are simplistic, writing very laborious, and computerized augmentative communication systems too costly. This inability to communicate effectively prevents optimal patient participation in their plan-of-care. Verbal communication, therefore, plays an integral role in psychological functioning, social interactions, and overall medical care. The primary criteria for determining success or failure of any one-way tracheotomy tube speaking valve is how well it allows for adequate voice intensity greater than ambient room noise to achieve both audible voice production and intelligible speech. The first purpose of this study is to investigate voice production and speech intelligibility abilities associated with the Blom low profile voice inner cannula and the Passy-Muir one-way tracheotomy tube speaking valves. It is hypothesized that there will be no significant differences between the two speaking valves regarding physiologic parameters, voice production, or speech intelligibility capabilities. There are conflicting reports in the literature regarding the relationship between a tracheotomy tube and swallowing success. Some authors report an improvement in swallowing success when the tracheotomy tube is occluded while others report no change in aspiration status based on occlusion status of the tracheotomy tube. Recently, it has been reported that there was no causal relationship between the tracheotomy tube and aspiration status. There is a paucity of research, to date, reporting on movement of the hyolaryngeal complex based upon occlusion status of a tracheotomy tube or presence of a tracheotomy tube. The second purpose of this study is to investigate how the Blom low profile voice inner cannula and the Passy-Muir one-way tracheotomy tube speaking valves impact on swallowing behavior and movement of the hyolaryngeal complex during routine diagnostic modified barium swallow evaluations.

Interventions

PROCEDUREBlom Low Profile Voice Cannula/Passty-Muir Speaking Valves

Sponsors

Yale University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Over 18 years of age, English speaking, and ability to tolerate a tracheotomy tube with a fully deflated tracheotomy tube cuff.

Exclusion criteria

* Inability to tolerate full tracheotomy tube cuff deflation or copious secretions preventing placement of a one-way tracheotomy tube speaking valve.

Design outcomes

Primary

MeasureTime frameDescription
Maximum Duration of Voicing (seconds)30 minutesMaximum duration of voicing (seconds) will be obtained, after instructing the patient to say the vowel /a/ as long as possible timed with a stopwatch.
Maximum Voice Intensity (dBA scale)30 minutesMaximum voice intensity (on the dBA scale) will be obtained, after instructing the patient to say the vowel /a/ as loud as possible, using a digital sound level meter placed 15 cm from the patient's lips.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026