Skip to content

Aqueous Flare of a Hydrophobic Acrylic Single-piece Open-loop IOL With Modified Material Surface Properties

Aqueous Flare of a Hydrophobic Acrylic Single-piece Open-loop IOL With Modified Material Surface Properties

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01767012
Acronym
POL
Enrollment
40
Registered
2013-01-11
Start date
2010-08-31
Completion date
2012-11-30
Last updated
2013-01-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract, Diabetes, Pseudoexfoliation Syndrome

Brief summary

Modern phacoemulsification techniques have made cataract surgery safe and efficient over the past several decades. Although the phacoemulsification procedure has improved greatly, cataract surgery still involves trauma. One of the surgical traumas during cataract surgery is the direct trauma of the anterior uvea, resulting in a later chronic immune reaction of the uvea to the implanted intraocular lens (IOL). 1 The breakdown of the blood-aqueous barrier (a measure of the uveal reaction) clinically presents as flare in the anterior chamber. 2 Petternel et al. 3 explained that the protein content of the aqueous humor may mainly arise from the iris root and iris vessels in the anterior chamber. The peak of this flare and cell intensity in the anterior chamber was shown to be reached during the first two days after cataract surgery 4 and flare levels were back to the preoperative values about one year after cataract surgery. 5, 6 Influencing factors are surgical technique 7, perioperative treatment 8, IOL biomaterial and design 9 and host reaction to the IOL. In this study the otherwise same IOL concerning material and design, but one with a new surface modification will be compared to assess the influence on aqueous flare and cell intensity in the anterior chamber. The Polylens (Polytech, Rossdorf, Germany) is a hydrophobic acrylic single-piece open-loop IOL and is available with the standard surface and a novel modified surface. To assess the efficacy of the newly modified surface of the Polylens IOL compared to the same IOL without a modified surface concerning flare and cell intensity in the anterior chamber as well as cellular components on the IOL surface and lens epithelial out-growth from the rhexis after cataract surgery in eyes of patients with diabetes mellitus and pseudoexfoliation syndrome, which typically have a higher incidence of post-operative intra-ocular inflammation.

Interventions

DEVICEPolylens EC-HY10-PAL (coated)

hydrophobic acrylic IOL with modified surface properties (Heparin-coating)

DEVICEPolylens EC-Y10-PAL (uncoated)

Sponsors

Vienna Institute for Research in Ocular Surgery
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
21 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Bilateral age-related cataract * Age 40 and older * Diabetes mellitus OR pseudoexfoliation syndrome

Exclusion criteria

* Preceding ocular surgery or trauma

Design outcomes

Primary

MeasureTime frameDescription
Amount of aqueous flare measured with a Laser flare meter1 hour - 3 months postoperativelyThe amount of aqueous flare was measured with a Laser flare meter (Kowa FM-600, Kowa Optimed, USA).The unit of measurement is photon counts per millisecond (pc/ms). The higher flare values, the higher the intracameral amount of protein and, therefore, the higher the intraocular inflammatory response.

Secondary

MeasureTime frameDescription
Anterior capsule opacification (measured as brightness of anterior capsular reflect on slitlamp photographs)1 hour to 3 months postoperativelyObjective ACO evaluation was obtained after taking 2 slit lamp images in a standardised way of each eye: the area of the anterior capsule in contact with the IOL was defined as the area of interest. Part of the dark area not directly illuminated by the slit beam within the capsulorhexis served as the control area. The difference in brightness between the area of interest and the control area defined the grade of fibrosis in per cent, with 0% representing a clear anterior capsule and 100%, a completely white anterior capsule.

Other

MeasureTime frameDescription
IOL centration measured with a Purkinje-meter3 months post-OPThe amount of IOL decentration (mm) was measured with a Purkinje-meter system, which analyses misalignment of the optical surfaces of the eye due to position of Purkinje-reflexes.
IOL tilt measured with a Purkinje-meter3 months postOPThe amount of IOL tilt (°) was measured with a Purkinje-meter system, which analyses misalignment of the optical surfaces of the eye due to position of Purkinje-reflexes.

Countries

Austria

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026