Comparing Harmonic Ultrasonic Scalpel to Small Jaw Bipolar Device in Thyroid Surgery

Randomized Controlled Trial Comparing the Utility of an Ultrasonic Coagulating Device (UCSD) With Electrothermal Bipolar Vessel Sealer (EBVS) in Thyroid Surgery.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01765686
Enrollment
100
Registered
2013-01-10
Start date
2012-12-31
Completion date
2016-09-30
Last updated
2017-05-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Thyroid Diseases

Brief summary

Energy devices are used routinely during thyroid surgery to aid surgical dissection and to stop bleeding. The newer generation energy devices have several advantages over older machines. The two most commonly used newer generation energy devices are the Harmonic scalpel and the Small Jaw bipolar device. Currently there has been no randomized controlled trial that compares both devices side to side. We aim to compare the effectiveness of these two newer generation energy devices in thyroid surgery.

Detailed description

Energy devices are used routinely during thyroid surgery to aid surgical dissection and haemostasis. The newer generation energy devices have several advantages over older machines. First, the newer devices deliver more focussed thermal application and thus are less likely to cause collateral injury to surrounding healthy tissue. This is particularly relevant in thyroid surgery because the thyroid gland is in close proximity to vital nerves that control our airway and glands that regulate calcium metabolism. Secondly, the newer energy devices have multifunctional properties and are capable of sealing, blunt dissection, grasping and dividing tissue. This is advantageous in thyroid surgery as the operating field has many narrow areas within and the potential reduction in the exchange of instruments facilitates surgery. Currently, two of these newer generation energy devices are available for use in Singapore General Hospital and National Cancer Centre Singapore. Both devices are similarly priced; one is based on an ultrasonic vibrating blade (UCSD) to cut and coagulate tissue while the other uses bipolar electrical energy and pressure to form a seal and a micro blade to divide the sealed tissue (EBVS). To date, clinical studies comparing both devices have only been done on animal models and focus on sealing times in animal blood vessels. We aim to compare the effectiveness of these two newer generation energy devices in thyroid surgery by looking at the incidence of post surgical complications, post operative drainage as well as the ease of use as reflected in the operating time.

Interventions

DEVICEHarmonic Scalpel (Ethicon Endo-Surgery, USA)
DEVICELigasure Small Jaw (Covidien, USA)

Sponsors

National Cancer Centre, Singapore
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
21 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* Age 21-75 * Histological confirmation of differentiated thyroid cancer requiring surgery, symptomatic goiters, thyroid nodules requiring histological analysis, or thyrotoxicosis poorly controlled my medication * Undergoing thyroid surgery

Exclusion criteria

* Previous neck radiotherapy * Previous neck surgery * Patients with advanced disease that would require radical or modified neck dissection * Patients with lobe larger than 10 cm or nodule larger than 8 cm which requires extensive dissection that may confound the study * Patients with connective tissue diseases or chronic diseases on long-term medications that may interfere with wound healing such as steroids. * Patients with bleeding diatheses.

Design outcomes

Primary

MeasureTime frameDescription
Duration of SurgeryDay 1: Day of SurgeryKife to skin time to closure time.
BleedingDay 1 and on day of drain removal.Measured blood loss during surgery including suction amount minus the irrigation fluid used as well as the number of gauzes. Drain amount is also recorded postoperatively

Secondary

MeasureTime frameDescription
Post op complicationsDay 2Voice hoarseness, adverse events, stridor, difficulty breathing and other common complications of thyroid surgery are recorded.
Ease of useDay 1Surgeon's comment on ease of use, number of nerve identified, number of parathyroid gland identified, staff's inputs on ease of use.
Vocal chords on nasal scope inspectionDay 15 and up to 3-months post-opNasal scope will be done for all subjects at 2-week post operative. If normal, subject does not need to undergo the 2nd nasal scope at 3-month visit.