Skip to content

Visual Performance of Pseudophakic Patient With Different Intraocular Lenses

Visual Performance of Pseudophakic Patient With Different Intraocular Lenses

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01763411
Acronym
ETDRS
Enrollment
80
Registered
2013-01-08
Start date
2008-01-31
Completion date
2016-12-31
Last updated
2016-02-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract, Eye Diseases, Lens Diseases

Keywords

Cataract, Vision, Intraocular lens, Multifocal, Monofocal

Brief summary

This retrospective study comprised patients with cataract, corneal astigmatism, and motivation for spectacle independence. In all cases, a multifocal and monofocal Intraocular Lens was been implanted in the capsular bag. Three months postoperatively, distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity was evaluated. A patient-satisfaction and visual phenomena questionnaire was also been administered.

Detailed description

Postoperative evaluation was performed at 3 months. The uncorrected and corrected distance visual acuity were assessed using the 100% contrast Early Treatment Diabetic Retinopathy Study chart, uncorrected intermediate visual acuity at 70 cm, and uncorrected near visual acuity at 40 cm; a binocular defocus curve was constructed using the ETDRS chart at 4 m and adding to the patient's manifest refraction +2.50 to -5.00 D sphere in 0.50 increments. The cylinder axis of the Intraocular lens (IOL) was measured at the slitlamp using the beam protractor after full mydriasis. The mean of the absolute values of degrees the intraocular lens was off axis was determined. Contrast sensitivity was measured using the CSV-1000 HGT instrument (VectorVision, Inc.), which presents a translucent chart divided into 4 cycles with spatial frequencies of 3, 6, 12 and 18 cycles per degree. The background illumination of the translucent chart does not depend on room lighting. All measurements were obtained under mesopic (5 cd/m2) and photopic (85 cd/m2) conditions. The examinations were performed unilaterally at a distance of 2.5 m with Best-corrected visual acuity (BCVA) and an undilated pupil. All measurements were performed under the same conditions. Patient satisfaction and quality of life were assessed by a simple questionnaire. Patients were interviewed 3 months postoperative. Patients were asked about visual disturbances, visual lifestyle activities, spectacle use, and satisfaction with the procedure.

Interventions

None listed

Sponsors

University of Sao Paulo
CollaboratorOTHER
Hospital Oftalmologico de Brasilia
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
55 Years to 85 Years
Healthy volunteers
Yes

Inclusion criteria

Cataract Any race Either gender Diagnosis of cataracts both eyes Pre-existing physical conditions that could skew visual results, such as Diabetes, Retinal detachment, Macular degeneration, or Cancer Subjects must have \> 1.00 diopter of astigmatism

Exclusion criteria

Central endothelial cell count less than 2000 cells/mm2 glaucoma or intraocular pressure greater than 21 mmHg amblyopia Retinal abnormalities Diabetes mellitus steroid or immunosuppressive treatment Connective tissue diseases

Design outcomes

Primary

MeasureTime frameDescription
Visual Performance in Pseudophakic Patients With Different Intraocular Lens6 months postoperativePostoperative evaluation was been performed at 6 months. The uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) was assessed using the 100% contrast ETDRS chart; a binocular defocus curve was constructed using the ETDRS chart at 4 m.

Secondary

MeasureTime frameDescription
Contrast sensitivity6 monthsContrast sensitivity was measured using the CSV-1000 HGT instrument (VectorVision, Inc.), which presents a translucent chart divided into 4 cycles with spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd). The background illumination of the translucent chart does not depend on room lighting. All measurements was obtained under mesopic (5 cd/m2) and photopic (85 cd/m2) conditions. The examinations was performed unilaterally at a distance of 2.5 m with BCVA and an undilated pupil. All measurements was performed under the same conditions.
Patient satisfaction6 monthsPatient satisfaction and quality of life was assessed by a simple questionnaire. Patients was interviewed 6 months postoperative. Patients was asked about visual disturbances, visual lifestyle activities, spectacle use, and satisfaction with the procedure.

Countries

Brazil

Outcome results

None listed