Skip to content

High Definition Endoscopy With i-Scan for Small Colonic Polyp Evaluation: The HiScope Study

A Prospective Single-blind Observational Cohort Study of High Definition White Light Endoscopy and i-Scan Image Enhancement for the Characterisation of Small Colonic Polyps

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01761279
Acronym
HiSCOPE
Enrollment
84
Registered
2013-01-04
Start date
2011-05-31
Completion date
2012-05-31
Last updated
2013-04-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Colonic Polyps

Keywords

Colonic polyps

Brief summary

Current standard practice is to remove all colonic polyps found during colonoscopy as it has not been possible to distinguish between polyps with some malignant potential (adenomatous) and those with negligable malignant potential (non-adenomatous). Recent advances in endoscope imaging and technology have allowed endoscopists to distinguish between these two types of polyps by examining minute surface details. i-Scan is a new digital enhancement method that aims to enhance surface details and may enable similar accurate distinction between adenomatous and non-adenomatous polyps. Hypothesis: High definition white light endoscopy plus i-Scan improves diagnostic accuracy of in-vivo assessment of colonic polyps \<10mm in size over high definition white light endoscopy alone.

Detailed description

Traditionally all polyps detected at colonoscopy, except obvious cancers, have been removed. It is felt that small (\<10mm diameter) hyperplastic polyps cannot be reliably distinguished from adenomatous polyps by endoscopists \[1\]. Therefore a large number of hyperplastic polyps are removed unnecessarily. This results in increased risk to patients through exposing them to unnecessary polypectomy, and increased cost to the health service through the cost of processing greater numbers of histopathology specimens. The cost per specimen is around £58. This challenge of distinguishing small hyperplastic polyps from small adenomatous polyps has been met over the past decade through the use of novel chromoendoscopy and computed 'virtual chromoendoscopy' techniques. Chromoendoscopy involves using staining or contrast dyes to highlight the minute surface patterns in the mucosa of the gastrointestinal tract. The dyes are applied to the colonic mucosa via the working channels of the endoscope. Vital stains such as cresyl violet and methylene blue, which are taken up into epithelial cells, have been used by Japanese endoscopists for many years. Work by Kudo et al showed that by using these stains in combination with magnification endoscopy the minute 'pit patterns' of colonic mucosal lesions could be precisely examined and classified. The pits described are the surface opening of the mucosal crypts. Kudo showed that the surface pit pattern could predict the histology of a lesion with high accuracy \[2-4\], enabling distinction between adenomatous and hyperplastic polyps. Concerns regarding potential harmful effects of vital stains increased the popularity of an alternative chromoendoscopy dye, indigocarmine \[5\]. Indigocarmine is not taken up by cells but lies on the colonic wall. Studies from East Asia, the USA and Europe published in the early part of the last decade showed that by combining indigocarmine and magnification endoscopy, neoplastic colonic polyps (adenomas) could be distinguished from non-neoplastic hyperplastic polyps with accuracy rates of 68-96% \[6-10\]. By the same method, surface patterns could also identify small early colorectal cancers\[11\] . Subsequent studies demonstrated that indigocarmine could adequately distinguish between adenomatous and hyperplastic polyps without the need for optical magnification \[12-15\]. During the past few years new methods of closely examining lesions within the colon have been developed. Digital imaging techniques or 'virtual chromoendoscopy' systems have been developed by endoscope manufacturers as a 'push-button' alternative to chromoendoscopy dyes, being potentially simpler and quicker to use. The first of these novel technologies available was the narrow band imaging (NBI) system produced by Olympus. A filter within the endoscope selects out narrow bandwidths of blue and green light, and thus reduces red light. These wavelengths penetrate only the superficial layers of the mucosa, highlighting surface patterns and microvasculature. Adenomatous polyps have more numerous and prominent microvessels in comparison to hyperplastic poylps. This system has been shown to be effective in differentiating small hyperplastic and adenomatous polyps with accuracies of 91 - 94% \[16-23\]. The Fujinon Intelligent Colour Enhancement (FICE) system developed by Fujinon uses post-processor electronic colour filter technology to allow a range of filter images with different wavelengths of light to be viewed. Similar results to NBI have been achieved in the characterisation of small polyps \[13, 24, 25\]. More recently a further virtual chromoendoscopy system, i-Scan has been developed by Pentax. i-Scan identifies areas of contrast between adjacent pixels (ie light bordering dark) and enhances this contrast. Additionally in a similar method to FICE, post-processor manipulation of the red, green and blue components of the spectrum is used to enhance vessels and surface structures. A single study from Germany has suggested that i-Scan improves the detection of lesions during flexible sigmoidoscopy and can accurately predict histology. There is a need for further data on the clinical efficacy of i-Scan in the assessment of colonic polyps, particularly in a UK population and in a bowel cancer screening population, neither of which have been studied to date. Through the use of these new technologies it may be possible to accurately predict the histology of small polyps in real time. Once an in-vivo diagnosis has been made with high confidence it may be possible for small hyperplastic polyps to be discarded, rather than sent for histological analysis, or to be left in situ \[22\]. This has potential benefits in reducing the frequency and consequent risk of polypectomy for patients and could also reduce pathology costs. UK and US guidelines for repeat surveillance colonoscopy after adenomas are detected at baseline examination are based on the number and size and histology of adenomas \[26, 27\]. At present these 'rescope intervals' are determined once the histology report of any resected polyps is received. With accurate in-vivo diagnosis these intervals may be set immediately after the baseline colonoscopy has been completed. Whilst the development of these endoscopic advanced imaging technologies is to be welcomed, it is important for studies to determine what can be achieved through their use, over and above standard white-light colonoscopy. The American Society for Gastrointestinal Endoscopy has identified the utility of technologies used in the real-time assessment of diminutive (\<5mm) colonic polyps as a key area for study, and has published guidelines on the minimum standards which new endoscopic technologies should meet before their use becomes widely adopted \[28\]. We aim to evaluate HDWL and HDWL + i-Scan for the real time assessment and prediction of histology of small colonic polyps in a BCSP population.

Interventions

Sponsors

Portsmouth Hospitals NHS Trust
Lead SponsorOTHER_GOV

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
60 Years to 74 Years
Healthy volunteers
No

Inclusion criteria

* Patients found to have colonic polyps up to 10mm in size

Exclusion criteria

* Poor bowel preparation * Inflammatory bowel disease * Polyposis syndrome

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic Accuracy of In-vivo Polyp AssessmentOnce histopathology results are known, approximately 2 weeks after in-vivo assessmentDiagnostic accuracy of in-vivo assessment of colonic polyps \<10mm in size using high definition white light endoscopy and high definition white light endoscopy plus i-Scan image enhancement. Accuracy compared to the gold standard of histopathology. Accuracy - number of polyps with histology correctly predicted by in-vivo method/total number of polyps assessed (Expressed as a percentage)

Secondary

MeasureTime frameDescription
Sensitivity for Adenomatous Histology of Colonic Polyps <10mm in SizeOnce histopathology results are known, approximately 2 weeks after in-vivo assessmentSensitivity for adenomatous histology of in-vivo assessment of colonic polyps \<10mm in size using high definition white light endoscopy and high definition white light endoscopy plus i-Scan image enhancement. Sensitivity compared to the gold standard of histopathology. Senstivity for adenomatous histology = number of correctly identified adenomas (true positives)/total number of adenomas (true positives + false negatives)
Specificity for Adenomatous Histology of Colonic Polyps <10mm in SizeOnce histopathology results are known, approximately 2 weeks after in-vivo assessmentSpecificity for adenomatous histology of in-vivo assessment of colonic polyps \<10mm in size using high definition white light endoscopy and high definition white light endoscopy plus i-Scan image enhancement. Specificity compared to the gold standard of histopathology. Specificity for adenomatous histology = number of correctly identified non-neoplastic polyps (true negatives)/total number of non-neoplastic polyps (true negatives + false positives)
Negative Predictive Value for Adenomatous Histology of Rectosigmoid Polyps ≤5mm in SizeOnce histopathology results are known, approximately 2 weeks after in-vivo assessmentNegative predictive value for adenomatous histology of rectosigmoid polyps ≤5mm in size using high definition white light endoscopy and high definition white light endoscopy plus i-Scan image enhancement. NPV compared to the gold standard of histopathology. Negative predictive value = number of true negatives/(number of true negatives + number of false negatives)

Other

MeasureTime frameDescription
Accuracy of Prediction of Polyp Surveillence IntervalsOnce histopathology results are known, approximately 2 weeks after in-vivo assessmentAccuracy of prediction of post-polypectomy surveillence colonoscopy intervasl based on national guidelines. Intervals based on in-vivo assessment of all polyps ≤5mm in size combined with histopathology of polyps \>5mm in size will be compared to intervals determined by histopathology of all polyps

Participant flow

Recruitment details

Patients attending for colonoscopy at Portsmouth Hospitals NHS Trust throught the Bowel Cancer Screening programme were recruited from May 2010-May 2011.

Pre-assignment details

Cohort study - single cohort. Patients found to have inflammatory bowel disease or a polyposis syndrome were excluded

Participants by arm

ArmCount
HDWL + I-Scan
High Definition White Light Endoscopy and i-Scan assessment performed of all polyps
84
Total84

Baseline characteristics

CharacteristicHDWL + I-Scan
Age Continuous67.6 Years
Sex: Female, Male
Female
25 Participants
Sex: Female, Male
Male
59 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
— / —
other
Total, other adverse events
0 / 84
serious
Total, serious adverse events
0 / 84

Outcome results

Primary

Diagnostic Accuracy of In-vivo Polyp Assessment

Diagnostic accuracy of in-vivo assessment of colonic polyps \<10mm in size using high definition white light endoscopy and high definition white light endoscopy plus i-Scan image enhancement. Accuracy compared to the gold standard of histopathology. Accuracy - number of polyps with histology correctly predicted by in-vivo method/total number of polyps assessed (Expressed as a percentage)

Time frame: Once histopathology results are known, approximately 2 weeks after in-vivo assessment

Population: There were 84 patients included in the study. 209 polyps \<10mm included in the study.

ArmMeasureValue (NUMBER)
HDWLDiagnostic Accuracy of In-vivo Polyp Assessment93.3 % diagnostic accuracy
i-ScanDiagnostic Accuracy of In-vivo Polyp Assessment94.7 % diagnostic accuracy
Secondary

Negative Predictive Value for Adenomatous Histology of Rectosigmoid Polyps ≤5mm in Size

Negative predictive value for adenomatous histology of rectosigmoid polyps ≤5mm in size using high definition white light endoscopy and high definition white light endoscopy plus i-Scan image enhancement. NPV compared to the gold standard of histopathology. Negative predictive value = number of true negatives/(number of true negatives + number of false negatives)

Time frame: Once histopathology results are known, approximately 2 weeks after in-vivo assessment

Population: Numbers indicate the number of rectosigmoid polyps \<5mm in size assessed as being non-neoplastic

ArmMeasureValue (NUMBER)
HDWLNegative Predictive Value for Adenomatous Histology of Rectosigmoid Polyps ≤5mm in Size100 Percentage Negative Predictive Value
i-ScanNegative Predictive Value for Adenomatous Histology of Rectosigmoid Polyps ≤5mm in Size100 Percentage Negative Predictive Value
Secondary

Sensitivity for Adenomatous Histology of Colonic Polyps <10mm in Size

Sensitivity for adenomatous histology of in-vivo assessment of colonic polyps \<10mm in size using high definition white light endoscopy and high definition white light endoscopy plus i-Scan image enhancement. Sensitivity compared to the gold standard of histopathology. Senstivity for adenomatous histology = number of correctly identified adenomas (true positives)/total number of adenomas (true positives + false negatives)

Time frame: Once histopathology results are known, approximately 2 weeks after in-vivo assessment

Population: 134 is the number of adenomatous polyps included in the study.

ArmMeasureValue (NUMBER)
HDWLSensitivity for Adenomatous Histology of Colonic Polyps <10mm in Size95.5 Percentage sensitivity
i-ScanSensitivity for Adenomatous Histology of Colonic Polyps <10mm in Size97.0 Percentage sensitivity
Secondary

Specificity for Adenomatous Histology of Colonic Polyps <10mm in Size

Specificity for adenomatous histology of in-vivo assessment of colonic polyps \<10mm in size using high definition white light endoscopy and high definition white light endoscopy plus i-Scan image enhancement. Specificity compared to the gold standard of histopathology. Specificity for adenomatous histology = number of correctly identified non-neoplastic polyps (true negatives)/total number of non-neoplastic polyps (true negatives + false positives)

Time frame: Once histopathology results are known, approximately 2 weeks after in-vivo assessment

Population: 75 is the number of non-neoplastic polyps included in the study.

ArmMeasureValue (NUMBER)
HDWLSpecificity for Adenomatous Histology of Colonic Polyps <10mm in Size89.3 Percentage specificity
i-ScanSpecificity for Adenomatous Histology of Colonic Polyps <10mm in Size90.7 Percentage specificity
Other Pre-specified

Accuracy of Prediction of Polyp Surveillence Intervals

Accuracy of prediction of post-polypectomy surveillence colonoscopy intervasl based on national guidelines. Intervals based on in-vivo assessment of all polyps ≤5mm in size combined with histopathology of polyps \>5mm in size will be compared to intervals determined by histopathology of all polyps

Time frame: Once histopathology results are known, approximately 2 weeks after in-vivo assessment

Population: 84 study participants in total. One patient excluded from this analysis as a single polyp was not retrieved for histological analysis.

ArmMeasureValue (NUMBER)
HDWLAccuracy of Prediction of Polyp Surveillence Intervals95.3 Percentage correct surveillence interval
i-ScanAccuracy of Prediction of Polyp Surveillence Intervals97.2 Percentage correct surveillence interval

Source: ClinicalTrials.gov · Data processed: Mar 23, 2026