Skip to content

Changes in Cardiac Function in COPD Patients After Administration of Budesonide/Formoterol (Symbicort®) Versus Placebo

Evaluation of Changes in Cardiac Function in COPD Patients With Resting Hyperinflation After Administration of Budesonide/Formoterol (Symbicort®) Compared With Placebo

Status
Terminated
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01760304
Acronym
AZCO
Enrollment
5
Registered
2013-01-04
Start date
2012-01-31
Completion date
2012-10-31
Last updated
2017-06-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chronic Obstructive Pulmonary Disease (COPD)

Keywords

COPD

Brief summary

To investigate whether Budesonide/Formoterol (Symbicort ®) therapy can improve heart function at rest by decreasing lung hyperinflation in patients with COPD (Chronic Obstructive Pulmonary Disease).

Detailed description

Patients with moderate to advanced COPD are known to have static hyperinflation (at rest) as a consequence of expiratory flow limitation. Hyperinflation is easily detected by measuring lung volumes during standard pulmonary function testing. Decreased Inspiratory Capacity (IC) secondary to hyperinflation has been described as a predictor of mortality in COPD, and as a limiting factor for the maximal tidal volume attained during exercise. Hyperinflation has been linked to a low cardiac output in part by limiting left ventricular ejection fraction during exercise. Treatment with inhaled anticholinergic agents or long-acting beta agonists (LABA) and combination of the LABA formoterol and budesonide has been shown to improve IC and decrease lung hyperinflation. Bronchodilators have been shown to improve exercise endurance in COPD when combined with pulmonary rehabilitation, however the exact mechanism: improvement of lung mechanics and /or improvement in cardiac function is not well known. Impedance cardiography (ICG) has emerged as a method to measure cardiac output without the need for invasive devices. Cardiac output measurement by impedance cardiography (CO-ICG) is a valid and reproducible method. It has been shown to have good correlation with thermodilution and the direct Fick method for the measurement of stroke volume and cardiac output. In addition, the oxygen pulse, easily obtained by dividing the measured oxygen uptake by the heart rate (VO2/HR) provides an adequate reflection of cardiac stroke volume when the systemic extraction of oxygen is stable. This method has been used to evaluate the effect of static and dynamic hyperinflation on cardiac function. This pilot study is designed to be a single center (Brigham and Women's Hospital), randomized, placebo-controlled, double blind, crossover study of 14 patients (male and female 40 to 80 years old) with COPD and static hyperinflation. The primary endpoint is the measurement of stroke volume, cardiac output and oxygen pulse at rest before and after the administration of budesonide/formoterol compared to placebo.

Interventions

Budesonide/ formoterol (B/F) 160/4.5 mcg per activation. Subject who met inclusion criteria will be have at each visit day lung function, heart function and breathlessness measurements at baseline, then they will receive 2 puffs of either Budesonide/formoterol (B/F) 160/4.5 mcg per activation (as per the randomization-crossover schema). After 45 minutes , the above measurements will be repeated.

DRUGPlacebo

Each visit day lung function, heart function and breathlessness measurements at baseline, then they will receive 2 puffs of placebo (as per the randomization-crossover schema). After 45 minutes , the above measurements will be repeated.

Sponsors

AstraZeneca
CollaboratorINDUSTRY
Brigham and Women's Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
40 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

Outpatients subjects of either sex between ages 40-80 years, with a diagnosis of COPD. COPD will be characterized as the presence of airflow obstruction with an FEV1/FVC \< 0.7 (Forced Expiratory Volume at one second / Forced Vital Capacity) and a FEV1 (Forced Expiratory Volume at one second ) 80% of predicted. All patients must have lung hyperinflation as demonstrated by an increase of ≥100 ml after the administration of budesonide/formoterol. All patients must have a cigarette smoking history of more than 10 pack-years, and be able to perform all the specified procedures as required by the protocol.

Exclusion criteria

1. Patients with other significant diseases (recent \< 6 weeks COPD exacerbation) that could place the patient at risk because of participation in the study, or which may influence the results of the study or the patients' ability to participate in the study. 2. All patients with a recent (\<1 year) history of myocardial infarction, or with a recent history of heart failure (NYHA class III and IV, pulmonary edema, or patients with cardiac arrhythmias. 3. Patients on daytime oxygen therapy. 4. Patients with known active tuberculosis. 5. Patients with a history of active cancer except for non-metastatic skin cancer. 6. Patients who have undergone thoracotomy, sternotomy, major cardiopulmonary intervention (lung resection, open heart surgery, etc), or other procedure in the 6 months prior to evaluation likely to cause instability of pulmonary status. 7. Patients with upper respiratory infection in the past six weeks.

Design outcomes

Primary

MeasureTime frameDescription
Cardiac OutputChange from Baseline and at 45 minutes after administration of study medication or placeboImpedance cardiography (ICG) (BioZ Dx ICG machine, by CardioDynamics) was used to measure cardiac output without the need for invasive devices. Cardiac output measurement by impedance cardiography (CO-ICG) is a plethysmography technique using sensors to detect the properties of the blood flow in the thorax. All subjects had on each visit a baseline measurement at rest and then 45 minutes after intervention (Budesonide/formoterol or Placebo). Measurement were performed at rest for 5 minutes to obtain a steady state and the last 2 minutes were taken for analysis as an averaged value labeled as pre and post intervention. For the analysis we calculated the difference from pre and post intervention at each visit. Paired t-test was used to compare the mean+/- SD of the pre and post difference when taking the study drug vs placebo.

Secondary

MeasureTime frameDescription
Lung HyperinflationChange from Baseline and after 45 minutes after administration of study medication or placeboEvaluation of lung hyperinflation as determined by Pulmonary function test where Inspiratory Capacity (IC) before and 45 minutes after the administration of the budesonide/formoterol or placebo.
Evaluation of O2 PulseChange from Baseline and 45 minutes after administration of study medication or placeboEvaluation of O2 Pulse is the measurement of oxygen consumption pre and post intervention

Countries

United States

Participant flow

Participants by arm

ArmCount
Budesonide / Formoterol First , Then Placebo
Subjects received in a blinded fashion Budesonide/Formoterol (Symbicort ® )2 inhalations (160/4.5) then placebo 2 inhalations Budesonide / Formoterol: Budesonide/ formoterol (B/F) 160/4.5 mcg per activation. Subject will have at each visit day lung function, heart function and breathlessness measurements at baseline, then they will receive 2 puffs Budesonide/formoterol (B/F) 160/4.5 mcg per activation (as per the randomization-crossover schema). After 45 minutes , the above measurements will be repeated.
2
Placebo First, Then Budesonide/Formoterol
Subjects received in a blinded fashion placebo 2 inhalation then Budesonide/Formoterol (Symbicort ® )2 inhalations (160/4.5) Subject will have at each visit day lung function, heart function and breathlessness measurements at baseline, then they will receive 2 puffs Placebo on visit 1 then Budesonide/formoterol (B/F) 160/4.5 msg per activation on visit 2 (as per the randomization-crossover schema). After 45 minutes , the above measurements will be repeated.
3
Total5

Baseline characteristics

CharacteristicBudesonide / Formoterol First , Then PlaceboTotalPlacebo First, Then Budesonide/Formoterol
Age, Continuous62 years
STANDARD_DEVIATION 7
67 years
STANDARD_DEVIATION 9
70 years
STANDARD_DEVIATION 10
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Black or African American
0 Participants0 Participants0 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Race (NIH/OMB)
White
2 Participants5 Participants3 Participants
Region of Enrollment
United States
2 participants5 participants3 participants
Sex: Female, Male
Female
0 Participants2 Participants2 Participants
Sex: Female, Male
Male
2 Participants3 Participants1 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 50 / 5
other
Total, other adverse events
0 / 50 / 5
serious
Total, serious adverse events
0 / 50 / 5

Outcome results

Primary

Cardiac Output

Impedance cardiography (ICG) (BioZ Dx ICG machine, by CardioDynamics) was used to measure cardiac output without the need for invasive devices. Cardiac output measurement by impedance cardiography (CO-ICG) is a plethysmography technique using sensors to detect the properties of the blood flow in the thorax. All subjects had on each visit a baseline measurement at rest and then 45 minutes after intervention (Budesonide/formoterol or Placebo). Measurement were performed at rest for 5 minutes to obtain a steady state and the last 2 minutes were taken for analysis as an averaged value labeled as pre and post intervention. For the analysis we calculated the difference from pre and post intervention at each visit. Paired t-test was used to compare the mean+/- SD of the pre and post difference when taking the study drug vs placebo.

Time frame: Change from Baseline and at 45 minutes after administration of study medication or placebo

ArmMeasureValue (MEAN)
Budesonide / FormoterolCardiac Output-0.1 ml/beat
PlaceboCardiac Output1.9 ml/beat
Comparison: a paired t-test was calculated comparing baseline measures and post interventionp-value: 0.7692-sided paired t-test
Comparison: a paired t-test was calculated comparing baseline measures and post interventionp-value: <0.0001paired T-test
Secondary

Evaluation of O2 Pulse

Evaluation of O2 Pulse is the measurement of oxygen consumption pre and post intervention

Time frame: Change from Baseline and 45 minutes after administration of study medication or placebo

ArmMeasureValue (MEAN)
Budesonide / FormoterolEvaluation of O2 Pulse-0.03 ml/beat
PlaceboEvaluation of O2 Pulse0.17 ml/beat
p-value: <0.05paired t-test
Secondary

Lung Hyperinflation

Evaluation of lung hyperinflation as determined by Pulmonary function test where Inspiratory Capacity (IC) before and 45 minutes after the administration of the budesonide/formoterol or placebo.

Time frame: Change from Baseline and after 45 minutes after administration of study medication or placebo

ArmMeasureValue (MEAN)
Budesonide / FormoterolLung Hyperinflation0.34 Liters
PlaceboLung Hyperinflation-0.058 Liters

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026