Skip to content

Drug Eluting Balloon Versus Drug Eluting Stent in PCI

Drug Eluting Balloon Versus Drug Eluting Stent in Coronary Artery Disease PCI: Insights From a Meta-analysis of 1462 Patients

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01760200
Enrollment
1462
Registered
2013-01-04
Start date
2012-08-31
Completion date
2012-12-31
Last updated
2013-01-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Keywords

Coronary angioplasty, Coronary stent, paclitaxel drug-eluting stent, drug eluting balloon

Brief summary

Drug eluting balloons (DEB) have been developed to overcome the limitations of drug eluting stent (DES), but clinical results of different studies about DEB are not consistent. Thus, we planned a meta-analysis to compare outcomes of DEB and DES in coronary artery disease (CAD).

Detailed description

Drug eluting balloons (DEB) have been developed to overcome the limitations of drug eluting stent (DES), but clinical results of different studies about DEB are not consistent. Thus, we performed a meta-analysis to compare outcomes of DEB and DES in coronary artery disease (CAD). The meta-analysis was performed according to the recommended methods \[14-15\]. A systematic search for eligible studies involved MEDLINE, CENTRAL, Embase, Highwire Press, Scopus and Google Scholar databases and was conducted without language restriction by two independent investigators (A.L. and A.R.), using the following keywords: drug, eluting balloon(s), DEB, coronary, angioplasty. Divergences were resolved by consensus. Endnote software v. 10 was used to build up libraries of results that were combined after erasing duplicates. The references of retrieved studies were searched manually for additional trials, and efforts to contact authors were performed to obtain further study details or additional references. The search is updated to December 2012. Selection criteria: citations were screened at title and abstract level and retrieved as full reports. * Inclusion criteria were: 1) randomized studies or cohort studies reporting a comparison between a DEB treated group and a DES treated group; 2) availability of reports of late lumen loss (LLL) and/or overall death and/or myocardial infarction (MI) and/or stent thrombosis (ST) and/or target lesion revascularization (TLR). * Exclusion criteria were: 1) duplicate reporting (in which case the manuscript reporting the largest sample or the longest follow-up was selected), 2) follow up of at least 6 months; 3) studies presenting composite major adverse cardiac events (MACE) without mentioning individual end points. Data were abstracted on pre-specified forms by 2 unblinded reviewers; divergences were resolved by consensus. Internal validity : the present meta-analysis was performed according to the Guidelines for randomized controlled trials of the Cochrane Collaboration and for non randomized studies in compliance with the Guidelines of the MOOSE group. Quality of included studies was appraised by 2 unblinded investigators. The risk of selection, performance, detection, and attrition bias (expressed as low risk of bias \[A\], moderate risk of bias \[B\], high risk of bias \[C\], or incomplete reporting leading to inability to ensure the underlying risk of bias \[D\]) were evaluated separately, as recommended. Non-randomized studies were evaluated using the Newcastle-Ottawa Scale a validated technique in assessing the quality of non-randomized studies. Data analysis and synthesis: Odds ratios (ORs) were computed from individual studies and pooled according to a fixed effect (e.g. inverse variance weighting) or random effect model in case of statistical heterogeneity. Two separate subgroup analysis were pre-specified: 1) exclusion of studies with small vessel and bifurcation PCI; 2) exclusion of non-randomized studies 3) exclusion of studies in which DEBs were not used together with BMS deployment. Results will be presented as overall meta-analysis and subgroups meta-analyses for DEB vs DES comparisons. Outcomes appraised were in-stent LLL, overall death, MI, ST and TLR. We used the Mantel-Haenszel method for combining ORs, a validated method to pool the data in a meta-analysis of binary outcomes. For the in-stent LLL outcome, the mean difference of 6-month LLL compared with baseline was used and the overall weighted mean difference (WMD) was built with the inverse variance method. Heterogeneity was assessed by Cochran's Q test, with 2-tailed p=0.1. Statistical inconsistency test (I2) was also employed to overcome the low statistical power of Cochran's Q test. The potential publication bias was examined by constructing a funnel plot, in which sample size was plotted against odds ratios. In addition, a mathematical estimate of the asymmetry of this plot was provided by a linear regression approach. Asymmetry was considered to be present if the intercept of the regression line did deviate significantly from zero. To explore and mitigate heterogeneity, pre-specified covariates (prevalence of diabetes in the study population and reference coronary vessel diameter) as potential confounders were considered in the meta-regression analysis. Pooling of data, subgroup analyses and publication bias tests were performed with Review Manager 5.1 (The Nordic Cochrane Center, Købehvn, Denmark) and StatsDirect v 2.7.8 (StatsDirect Ltd, Cheshire WA, UK). Meta-regression analyses were builded with Comprehensive Meta-analysis Version 2 (Biostat, Englewood, New Jersey, United States).

Interventions

None listed

Sponsors

Azienda Ospedaliero Universitaria Maggiore della Carita
Lead SponsorOTHER

Study design

Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 89 Years
Healthy volunteers
No

Inclusion criteria

* randomized studies or cohort studies reporting a comparison between a DEB treated group and a DES treated group * availability of reports of late lumen loss (LLL) and/or overall death and/or myocardial infarction (MI) and/or stent thrombosis (ST) and/or target lesion revascularization (TLR).

Exclusion criteria

* duplicate reporting (in which case the manuscript reporting the largest sample or the longest follow-up was selected) * follow up of at least 1 year * studies presenting composite major adverse cardiac events (MACE) without mentioning individual end points.

Design outcomes

Primary

MeasureTime frameDescription
Overall mortality1 yearmortality rate from all cause

Secondary

MeasureTime frameDescription
Myocardial infarction rates1 yearMyocardial infarction rates
Target vessel revascularization1 yearsymptoms or ischemia driven new revascularization of the coronary artery already treated with DEB at baseline

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 23, 2026