Effect of Body Position Changes on Endotracheal Tube Cuff Pressure in Ventilated Critically Ill Patients

Effect of Body Position Changes on Endotracheal Tube Cuff Pressure in Ventilated Critically Ill Patients.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01757912
Acronym
CP
Enrollment
12
Registered
2012-12-31
Start date
2011-02-28
Completion date
2011-06-30
Last updated
2012-12-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mechanical Ventilation With Oral Intubation

Keywords

mechanical ventilation

Brief summary

The endotracheal tube secures free airway in patients undergoing surgical procedures or mechanical ventilation. The extraluminal airway needs to be sealed by a cuff. The cuff needs to be adequately inflated with air. The cuff pressure should be between 20 and 30 cm H2O. A cuff pressure in excess of the target range is associated with a risk of tracheal injury, whereas a cuff pressure below the lower limit includes a risk of micro-aspiration of subglottic secretions, with risk of subsequent ventilator-associated pneumonia. It is unknown whether the cuff pressure changes following changes in body position of the patient. The objective of this study is to investigate to which extent - if any - cuff pressures change after body position changes of the patient.

Interventions

PROCEDUREcuff pressure

The patient will be positioned in 16 distinct body positions, immediately after correct positioning, the cuff pressure is measured during an end-expiratory ventilator hold.

Sponsors

General Hospital Sint-Blasius Dendermonde
CollaboratorUNKNOWN
University Hospital, Ghent
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

are age 18 - 70 years, oral intubation with a taperguard EVAC endotracheal tube (Covidien®), conventional mechanical ventilation, adequate sedation (Richmond Agitation-Sedation Scale -5) and analgesia (Behavior Pain Scale 3 to 4).

Exclusion criteria

are factors with potential influence on the cuff pressure or factors that disturbed the safety or well-being of the patient: pregnancy, palliative care, difficult intubation, decreased mobility of the neck, history of neck surgery, temperature of \<35°C or \>37.5°C, morbid obesity (body mass index \>35) and every potential contra-indication for position changes such as unstable spinal cord injury or hemodynamic and/or respiratory instability.

Design outcomes

Primary

MeasureTime frameDescription
absolute values of cuff pressure (in cm H20) an number of measurement outside target range.During surgical procedure or mechanical ventilation.Cuff pressure measurement will be executed with a universal pressure monitor.The patient will be positioned in 16 distinct body positions, immediately after correct positioning, the cuff pressure is measured during an end-expiratory ventilator hold. Cuff pressure is evaluated in the following 16 body positions: anteflexion of the head, hyperextension of the head, left lateral flexion of the head, right lateral flexion of the head, left rotation of the head, right rotation of the head, semirecumbent position with a 45° head of bed elevation, recumbent position with 10° head of bed elevation, horizontal backrest, trendelenburg 10°, left lateral position over 30°, 45° and 90°, and right lateral position over 30°, 45° and 90°.

Countries

Belgium

Outcome results

None listed