Skip to content

Evaluation of Oxygen Consumption and Energy Expenditure During Spontaneous Breathing Trial.

Evaluation of Oxygen Consumption and Energy Expenditure During Spontaneous Breathing Trial - A Randomized Crossover Controled Trial.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01757093
Enrollment
40
Registered
2012-12-28
Start date
2012-06-30
Completion date
2013-09-30
Last updated
2014-12-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Respiratory Failure

Keywords

INDIRECT CALORIMETRY, MECHANICAL VENTILATION, WEANING VENTILATOR, AUTOMATIC TUBE COMPENSATION

Brief summary

The purpose of this study is to compare the oxygen consumption and energy expenditure during the spontaneous breathing trial.

Detailed description

Patients is going to submit to the 2 spontaneous breathing trial ( Automatic tube compensation plus continuous positive airway pressure and continuous positive airway pressure without automatic tube compensation. The oxygen consumption and energy expenditure is going to measure during the spontaneous breathing trial by indirect calorimetry.

Interventions

DEVICEAutomatic Tube Compensation plus CPAP

SPONTANEOUS BREATHING TRIAL WITH AUTOMATIC TUBE COMPENSATION plus CPAP

DEVICEContinuous Positive Airway Pressure

SPONTANEOUS BREATHING TRIAL WITH CPAP

Sponsors

University of Sao Paulo
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
SUPPORTIVE_CARE
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* IMPROVEMENT OR RESOLUTION OF THE UNDERLYING CAUSE OF DISEASE * INTUBATED PATIENTS\>24h * PaO2 GREATER THAN 60 mmHg WITH FiO2 LESS THAN 40% * PEEP=5 cmH2O

Exclusion criteria

* CARDIOVASCULAR INSTABILITY * FEBRILE OR HYPOTHERMIA * CHEST DRAINAGE * RESPIRATORY RATE/TIDAL VOLUME RATIO GREATER THAN 105 * PREGNANCY * FAIL IN THE SPONTANEOUS BREATHING TRIAL * LEAKS IN THE CIRCUIT * AGITATION * NOT ACCEPT PARTICIPATE IN THE STUDY

Design outcomes

Primary

MeasureTime frameDescription
Measurement of oxygen consumption through indirect calorimetry.The measurement is during the spontaneous breathing trial, 30 minutes.Measurements using indirect calorimetry for determination of oxygen consumption

Secondary

MeasureTime frameDescription
Measurement of energy expenditure through indirect calorimetryThe measurement is during the spontaneous breathing trial, 30 minutes.Measurement using indirect calorimetry for determination of energy expenditure.

Countries

Brazil

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026