BuMA OCT Study(A Comparative Evaluation of the Extent of Neointima Formation at 3 Months After Implantation Using OCT)

BuMA OCT Study(A Comparative Evaluation of BuMA Stent and of EXCEL Stent in Terms of the Extent of Neointima Formation at 3 Months After Implantation Using OCT)

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01752582
Enrollment
80
Registered
2012-12-19
Start date
2012-12-31
Completion date
Unknown
Last updated
2016-03-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Heart Disease, Silent Myocardial Ischemia, Stable Angina Pectoris, Unstable Angina Pectoris

Keywords

BuMA, EXCEL, OCT, stent, neointima formation

Brief summary

The objective of this study is a comparative evaluation of BuMA stent and of EXCEL stent in terms of the extent of neointima formation at 3 months after implantation using OCT. This is a prospective, single center, randomized, open-label, non-inferiority study, which will enroll a total of 70 patients in Fuwai Hospital.All patients will be randomly assigned undergoing implantation of BuMA stent or EXCEL stent (in a 1:1 ratio). If non-inferiority was met, superiority test will be planned.

Detailed description

About 70 patients with clinical evidence of ischemic heart disease and / or a positive functional study and documented stable angina pectoris (Canadian cardiovascular society classification (CCS)1, 2, 3 or 4), or documented silent ischemia in de-novo, native, previously unstented vessel in Fuwai Hospital,will be randomly assigned undergoing implantation of BuMA stent or EXCEL stent (in a 1:1 ratio). All of the patients will receive 6 months dual antiplatelet therapy and they will be followed (at the outpatient clinic) for up to 2 years. The follow-up visits will be conducted at 3 months (including angiographic/OCT investigation), 6 months, 1 and 2 years post percutaneous coronary intervention(PCI),in order to observe the Primary Endpoint and Secondary Endpoints.

Interventions

DEVICEBuMA stent

About 35 patients will undergoing implantation of BuMA stent and receive 6 months dual antiplatelet therapy.

DEVICEEXCEL stent

About 35 patients will undergoing implantation of EXCEL stent and receive 6 months dual antiplatelet therapy.

Sponsors

Sino Medical Sciences Technology Inc.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

* 18 to 85 years. * Evidence of myocardial ischemia without raised troponin (e.g. stable or unstable angina, silent ischemia demonstrated by positive territorial functional study). * The patient has a planned intervention of up to four de novo lesions, in different epicardial vessels. * Lesion(s) must have a visually estimated diameter stenosis of ≥50% and \<100%. * Reference Vessel Diameter(RVD) must be between 2.5-4.0 mm * Written informed consent. * The patient and the patient's physician agree to the follow-up visits including angiographic follow-up and OCT controls at 3 months.

Exclusion criteria

* Evidence of ongoing acute myocardial infarction in ECG prior to procedure. * Left ventricular ejection fraction(LVEF) \<30%. * Documented or suspected liver disease (including laboratory evidence of hepatitis). * Known renal insufficiency (e.g. estimated glomerular filtration rate(eGFR) \<60 ml/kg/m2 or serum creatinine level of \>2.5 mg/dL, or subject on dialysis). * History of bleeding diathesis or coagulopathy. * The patient is a recipient of a heart transplant. * Known hypersensitivity or contraindication to aspirin, both heparin and bivalirudin, antiplatelet medication specified for use in the study (clopidogrel and ticlopidine), sirolimus or stainless steel. * Other medical illness (e.g. cancer, neurological deficiency) or known history of substance abuse (alcohol etc.) as per physician judgment that may cause non-compliance with the protocol or confound the data interpretation or is associated with a limited life expectancy. * Pregnant or breastfeeding woman or woman in fertile period not taking adequate contraceptives OCT

Design outcomes

Primary

MeasureTime frameDescription
the percentage of the struts'neointimal coverage (%) at 3 months follow-up by OCT assessment.three months after surgeryThe primary outcome measure is the percentage of the struts'neointimal coverage (%) at 3 months follow-up by OCT assessment.

Secondary

MeasureTime frameDescription
Mean/Minimal Stent diameter/area/volumethree months after surgeryIt will be measure the Mean/Minimal stent diameter/area/volume at 3 months follow-up by OCT assessment.
Device-oriented Composite Endpoints and its individual components at 1 yearone year after surgeryDevice-oriented Composite Endpoint (DoCE) is defined as cardiac death, MI not clearly attributable to a non-intervention vessel, and clinically-indicated target lesion revascularization.
Mean/Minimal Lumen diameter/area/volumethree months after surgeryIt will be measure the Mean/Minimal Lumen diameter/area/volume at 3 months follow-up by OCT assessment.
Mean/maximal thickness of the struts coveragethree months after surgeryIt will be measure the Mean/maximal thickness of the struts coverage at 3 months follow-up by OCT assessment.
Incomplete strut appositionthree months after surgeryIt will be measure the incomplete strut apposition at 3 months follow-up by OCT assessment.
Minimal Lumen Diameter(MLD) and Diameter stenosis percentage(%DS) post procedure and at 3 monthsthree months after surgery
Late Lumen Loss at 3 monthsthree months after surgery
Binary Restenosis (DS ≥50%) at 3 monthsthree months after surgeryAll measurements will be made of the in-stent, in-segment, proximal and distal stent margins.
Neointimal hyperplasia area/volumethree months after surgeryIt will be measure the neointimal hyperplasia area/volume at 3 months follow-up by OCT assessment.
Device-oriented Composite Endpoints and its individual components at 3 monthsthree months after surgeryDevice-oriented Composite Endpoint (DoCE) is defined as cardiac death, Myocardial Infarction(MI) not clearly attributable to a non-intervention vessel, and clinically-indicated target lesion revascularization.
Device-oriented Composite Endpoints and its individual components at 6 monthssix months after surgeryDevice-oriented Composite Endpoint (DoCE) is defined as cardiac death, MI not clearly attributable to a non-intervention vessel, and clinically-indicated target lesion revascularization.
Device-oriented Composite Endpoints and its individual components at 2 years2 years after surgeryDevice-oriented Composite Endpoint (DoCE) is defined as cardiac death, MI not clearly attributable to a non-intervention vessel, and clinically-indicated target lesion revascularization.
Stent thrombosis according to the ARC definitions at 3 monthsthree months after surgery
Stent thrombosis according to the ARC definitions at 6 monthssix months after surgery
Stent thrombosis according to the ARC definitions at 1 yearone year after surgery
Stent thrombosis according to the ARC definitions at 2 years2 years after surgery
Acute success rateup to 7 days after surgeryIt includes the device success,lesion success and procedural success.