Comparing Validity of Non-Invasive Hemoglobin Monitoring to Laboratory Results in Critically Ill Children

Verifying the Accuracy of the Masimo Pronto Non-Invasive Hemoglobin (Hb) Monitor and Associated Rainbow Probes Compared to Measured Laboratory Values in Critically Ill Pediatric Patients

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01750463
Enrollment
65
Registered
2012-12-17
Start date
2013-01-31
Completion date
2013-05-31
Last updated
2014-12-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hemoglobin Results

Keywords

Pediatric critically ill, Masimo, hemoglobin, monitoring, UNC, PICU

Brief summary

This is a prospective study to determine the accuracy of the Masimo Pronto Non-Invasive Hemoglobin Monitor and associated Rainbow® probes in the detection of hemoglobin concentration in critically ill children.

Detailed description

This is a prospective study to determine the accuracy of the Masimo Pronto Non-Invasive Hemoglobin Monitor and associated Rainbow® probes in the detection of hemoglobin concentration in critically ill children. Data from at least 30 patients admitted to the Pediatric Intensive Care Unit (PICU) over a period of 2 months will be collected and analyzed for this study. Note, that this device would not lead to deviations in routine patient care; specifically, the non-invasive monitor placed on the patient's finger is FDA approved. The proposed monitors are identical macroscopically to monitors, which are currently used to measure oxygen saturation at this institution. Clinical decisions, additional blood draws or alterations to the plan of care will not be made based on study data. The objective is to compare the validity of the hemoglobin values determined from non-invasive technology with measured laboratory values for hemoglobin utilized as standard of care.

Interventions

OTHERMasimo Pronto Rad 7 Non-Invasive hemoglobin monitor

Patients admitted to PICU requiring hemoglobin monitoring will have a total hemoglobin (SpHb) assessment from Masimo non-invasive monitor, prior to standard, required blood draw and laboratory analysis.

OTHERStandard Laboratory Blood Draw and Hemoglobin Analysis

Patients admitted to PICU requiring hemoglobin monitoring will have a reading from Masimo non-invasive monitor, prior to standard, required blood draw and laboratory analysis.

Sponsors

University of North Carolina, Chapel Hill
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
30 Days to 18 Years
Healthy volunteers
No

Inclusion criteria

* Patient has been admitted to Pediatric Intensive Care Unit * Patient age is ≥ 30 days old and ≤ 18 years old * Patient weight ≥ 3 Kg. * Patient requires hemoglobin monitoring

Exclusion criteria

* Patient does not have exposed fingers/toes,due to congenital anomalies wound dressing or injury. * Patient weight is less than 3 Kg * Patient is less than 30 days old

Design outcomes

Primary

MeasureTime frameDescription
Comparison of standard hemoglobin monitoring vs. the MASIO non-invasive hemoglobin monitorup to 48 hours, post PICU admissionWe will obtain measurements using the Masimo Pronto device prior to the standard lab draw at the following time points: post admission to PICU, 12-48 hours. We will then perform analysis using Bland Altman methods to determine the degree of agreement. Data analysis will occur 1 year after enrollment completion.