Skip to content

Evaluation of Bisphosphonate Coated Pins for Extern Fixation in Tibia Osteotomy

Evaluation of Bisphosphonate Coated Pins for Extern Fixation in Tibia Osteotomy

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01745276
Acronym
PFX
Enrollment
20
Registered
2012-12-10
Start date
2011-04-30
Completion date
2013-02-28
Last updated
2018-09-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Osteoarthritis

Keywords

Pin fixation, Osteotomy, hemicallotasis

Brief summary

The purpose of this study is to evaluate the relative osseomechanical strength of a novel coated pin/screw in a clinical model.

Detailed description

The pin fixation and the risk for pin loosening and pintract infection is intimately connected Moroni et al., Magyar et al. Toksvig-Larsen and W-Dahl) The pin performance ratio for insertion to extraction torque (PPI) varies significantly between screw types. The extraction torque force is the most important value and it is estimated that a removal torque around 300 Nm probably will be the best bon-pin fixation in clinical practice. In animal studies and even in clinical studies the hydroxyapatite (HA) coated screw retained the highest level of osseointegration. However, the fixation for HAscrews is, especially in diaphyseal bone, the risk for too tight fixation, with extreme difficulties to remove the screws in few cases as a result ( high pain and seldom it is impossible to remove the screw) Coating by biphosphonate is a new novel technique with preclinical appealing performance, which theoretically should make this coating very appealing in clinical practice. The theory behind this technique is that it create a good pinfixation reasonable easy to remove. The current most used cortical screw designs performed poorest in terms of fixation (PPI) Method Using the hemicallotasis technique for correction in high tibial osteotomies today, HA coated (Osteotite) conical 130/50 screws is used in the proximal tibia - the metaphysic - and plain (standard) cortical conical screws 110/40 is used in the diaphysis. To study the effect of an improved pin coating a study including 30 patients randomised to the standard procedure today or the novel technique using biphosphonate coated screws. In the metaphysic, the randomisation will be between the HA coated (Osteotite) screws and the biphosphonated coated screws 130/50 (screw thread 50mm) In the diaphysis the randomisation will be between the plain standard 110/40 screws and the biphosphonate 110/40 coated screws Totally 30 patients will be studied which means totally 120 pins. This has been based on power calculations resulting in 23 patients in each group and calculated on extraction torque force. This is a clinical study and 30 patients is estimated due to expected drop out.

Interventions

DEVICEBiphosfonate

External pins coated by biphosfonate.

DEVICEHydroxylapatit

External pins coated by Hydroxylapatit.

Sponsors

Addbio AB
CollaboratorINDUSTRY
Region Skane
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
20 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* All patients which are diagnosed with arthr and needs an operation.

Design outcomes

Primary

MeasureTime frameDescription
To evaluate the relative osseomechanical strength of a novel coated pin/screw in a clinical mode.2011-07-01-2012-02-01To evaluate the relative osseomechanical strength of a novel coated pin/screw

Countries

Sweden

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026