CardioQ vs Thermodilution Measurements of Cardiac Output

Comparison of CardioQ and Pulmonary Artery Thermodilution Derived Cardiac Output Measurements

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01744795
Enrollment
25
Registered
2012-12-07
Start date
2012-12-31
Completion date
2013-06-30
Last updated
2013-06-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Comparison of CardioQ and Thermodilution Derived Cardiac Output Measurements

Keywords

cardiac output, thermodilution, esophageal doppler, trending ability

Brief summary

Minimal invasive monitoring systems of central hemodynamics are gaining increasing popularity. The present study investigates the precision of the esophageal doppler (CardioQ) derived cardiac output and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measuring CO during steady state and with induced hemodynamic changes in patients scheduled for elective cardiac surgery.

Detailed description

Twenty-five patients are planned to be enrolled. After induction of anesthesia, insertion of the PAC and the esophageal-doppler probe, the patient are placed in the following successive positions: a) supine, b) head-down tilt, c) head-up tilt, d) supine, e) supine with phenylephrine administration f) pace heart rate 80 bpm, g) pace heart rate 110 bpm, and CO are measured simultaneously using the CardioQ and PAC TD.

Interventions

OTHERinduced changes in hemodynamics

Twenty-five patients are planned enrolled. After induction of anesthesia, insertion of the PAC and the CardioQ probe, the patient are placed in the following successive positions: a) supine, b) head-down tilt, c) head-up tilt, d) supine, e) supine with phenylephrine administration f) pace heart rate 80 bpm, g) pace heart rate 110 bpm. CO are measured simultaneously using the TEE and thermodilution technique.

Sponsors

Hasse Moller-Sorensen
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* patients scheduled for elective coronary artery bypass grafting (CABG), who are in stable sinus rhythm, who have a left ventricular ejection fraction \> 0.40 measured by transthoracic echocardiography, and who have no significant valve pathology

Exclusion criteria

\-

Design outcomes

Primary

MeasureTime frameDescription
Agreement of cardiac output determined with CardioQ, compared with thermodilutionData are collected in the perioperative period (30min.)Data are collected for each patient in the perioperative period. Patients are followed in the first 24 hours. Data will after inclusion of the last data be analysed and appropiate statistics aplied.