Brief summary

Long term results after Ahmed glaucoma valve implantation for uncontrolled glaucoma are retrospectively examined.

Detailed description

The development of intraocular pressure, visual acuity, number of glaucoma medication, number of complications and necessity of revision operations after Ahmed glaucoma valve implantation for uncontrolled glaucoma is examined yearly for a period of 4 years.

Interventions

PROCEDUREAhmed valve

The flexible plate 7 (FP7) model (New World Medical) was implanted in patients with uncontrolled glaucoma.

Sponsors

Technische Universität Dresden
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients suffering from medically uncontrolled glaucoma * Informed consent

Exclusion criteria

* healthy subjects * under 18 years

Design outcomes

Primary

MeasureTime frameDescription
intraocular pressure reduction4 yearsThe reduction of intraocular pressure after Ahmed glaucoma valve implantation is observed over a period of 4 years.

Secondary

MeasureTime frameDescription
development of visual acuity4 yearsThe development of visual acuity after Ahmed glaucoma valve implantation is being examined over a period of 4 years.

Other

MeasureTime frameDescription
reduction of glaucoma medication4 yearsThe number of glaucoma medication after Ahmed glaucoma valve implantation are being examined over a period of 4 years.
postoperative complications4 yearsPossible postoperative complications after Ahmed glaucoma valve implantation are being examined over a period of 4 years.
need for revision operation4 yearsThe need for revision operations after Ahmed glaucoma valve implantation is being examined over a period of 4 years.