Comparison of Pulmonary Vein Isolation Using SmartTouch® Catheter With or Without Real-time Contact Force Data

A Randomised Study Comparing Pulmonary Vein Isolation Using SmartTouch® Catheter With or Without Real-time Contact Force Data. The SMART Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01730924
Enrollment
120
Registered
2012-11-21
Start date
2012-12-31
Completion date
Unknown
Last updated
2016-09-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation, Atrial Fibrillation Ablation, Pulmonary Vein Isolation

Keywords

Atrial fibrillation, Contact force, Ablation

Brief summary

The most widely used approach for the invasive treatment of paroxysmal atrial fibrillation is catheter ablation, by which radiofrequency energy is used to heat the tip of an ablation catheter to deliver targeted burns on the inner surface of the heart. The aim of this approach is to cause electrical isolation of the pulmonary veins. The purpose of this study is to evaluate whether the information which can be derived from the latest catheter technologies - on the degree of contact force between the catheter and the heart - affects the time to perform the procedure, or the outcomes as a result of it. Patients undergoing pulmonary vein isolation will be randomised to having their procedure performed with the contact force information available to the operator, or not available. The time taken to achieve pulmonary vein isolation is the primary end-point of the study.

Interventions

PROCEDUREPulmonary vein isolation using contact force sensing catheter

Sponsors

Queen Mary University of London
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Primary purpose
TREATMENT

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

Age \> 18 years, Symptomatic paroxysmal atrial fibrillation (defined as ECG proven episodes of atrial fibrillation which are self limiting and last less than 7 days on each occasion)

Exclusion criteria

Inability or unwillingness to receive oral anticoagulation Previous ablation procedure for atrial fibrillation Unwillingness or inability to complete the required follow up arrangements Persistent atrial fibrillation Prior prosthetic mitral valve replacement or severe structural cardiac abnormality Known severe left ventricular systolic function (ejection fraction \<35%) Known hypertrophic or infiltrative cardiomyopathy

Design outcomes

Primary

MeasureTime frame
Time to achieve pulmonary vein isolation in patients undergoing catheter ablation for paroxysmal atrial fibrillaiton

Countries

United Kingdom

Outcome results

None listed