Skip to content

Proseal Laryngeal Mask Airway or Endotracheal Tube for Emergence From Neuroanesthesia

Proseal Laryngeal Mask Airway Attenuates Systemic and Cerebral Hemodynamic Response During Awakening of Neurosurgical Patients

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01718470
Enrollment
42
Registered
2012-10-31
Start date
2011-07-31
Completion date
2012-03-31
Last updated
2012-10-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypertension on Emergence

Keywords

Systolic blood pressure, Heart rate, Laryngeal mask, Endotracheal tube, craniotomy

Brief summary

Extubation and emergence from anesthesia lead to systemic and cerebral hemodynamic changes that can cause cerebral edema and hemorrhage. The hemodynamic profile on emergence is more favorable if a laryngeal mask airway (LMA) is inserted before neurosurgical patients emerge from anesthesia. We aimed to compare the impact of awakening neurosurgery patients after insertion of a ProSeal LMA to replace the endotracheal tube (ETT).

Detailed description

At the end of surgery, the anesthesiologist opened a sealed envelope labeled with software-generated randomized numbers to learn the patient's assignment to one of two groups to emerge from anesthesia with the ETT still in place or after it had been replaced by an LMA. Hemodynamic variables were recorded at 8 moments: baseline, in the operating room one minute before anesthetic induction; 5 minutes after the end of surgery before awakening (ETT group) or before tube replacement (LMA group); and 1, 5, 10, 15, 30 and 60 min after extubation or LMA removal (according to group assignment).

Interventions

PROCEDUREEndotracheal tube

Hemodynamic variables were recorded at 8 moments: baseline, in the operating room one minute before anesthetic induction; 5 minutes after the end of surgery before awakening (ETT group) and 1, 5, 10, 15, 30 and 60 min after extubation . The last blood pressure and heart rate measurements were taken in the postoperative recovery room.

PROCEDURELMA

Hemodynamic variables were recorded at 8 moments: baseline, in the operating room one minute before anesthetic induction; 5 minutes after the end of surgery before tube replacement (LMA group); and 1, 5, 10, 15, 30 and 60 min after LMA removal. The last blood pressure and heart rate measurements were taken in the postoperative recovery room.

Sponsors

Fundacion Clinic per a la Recerca Biomédica
CollaboratorOTHER
Ricard Valero
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Elective craniotomy

Exclusion criteria

* Difficult airway * Uncontrolled hypertension before surgery * gastroesophageal reflux

Design outcomes

Primary

MeasureTime frame
systolic blood pressure change1 minute before anesthesia induction, 5 minutes before extubation, and minute 1, 5, 10, 15, 30 and 60 after extubation

Secondary

MeasureTime frame
heart rate change1 minute before anesthesia induction, 5 minutes before extubation, and minutes 1,5,10,15,30 and 60 after extubation

Other

MeasureTime frame
Norepinephrine plasma concentration change1 minute before anesthesia induction, 1 minute and 30 minutes after extubation,

Countries

Spain

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026