Radial Reload Laparoscopic LAR Case Series

Evaluating the Radial Reload Stapler With Tri-Staple TM Technology During Laparoscopic Low Anterior Resection for Rectal Cancer: A Prospective Multicenter Case Series

Status
Terminated
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01706822
Enrollment
8
Registered
2012-10-15
Start date
2013-04-30
Completion date
2013-11-30
Last updated
2015-03-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Colorectal Cancer

Brief summary

To evaluate the Radial Reload Stapler during laparoscopic low anterior resection (LAR) or anterior proctosigmoidectomy for rectal cancer by assessing the primary and secondary endpoints.

Interventions

Case series of patients arlaedy selected to undergo a laparoscopic LAR using the Radial Reload stapler

Sponsors

University Hospitals Cleveland Medical Center
CollaboratorOTHER
Duke University
CollaboratorOTHER
Medtronic - MITG
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

1. The subject is able to understand and sign Informed Consent Form. 2. The subject is between 18-85 years of age. 3. The subject is anticipated to undergo a resection of the rectum with anastomosis below the peritoneal reflection. 4. The subject is anticipated to undergo mobilization and stapling of the rectum laparoscopically.

Exclusion criteria

1. Any female patient, who is pregnant, suspected pregnant, or nursing. 2. The participant is unable or unwilling to comply with the study requirements, follow-up schedule. 3. The participant has co-morbidities which, in the opinion of the investigator, will not be appropriate for the study.

Design outcomes

Primary

MeasureTime frameDescription
The Surgeon's Ability to Achieve a Staple Line at the Desired Level of the Rectum. The Reported Value Represents the Number of Participants in Whom the Criteria Was MetOperativeThe surgeon's ability to achieve a staple line at the desired level of the rectum.
The Ability to Achieve Adequate Distal Margins (Defined as >2cm [or >1cm With Clear Histologic Evaluation]) in the Low Rectum. The Reported Value Represents the Number of Participants in Whom the Criteria Was MetOperativeThe ability to achieve adequate distal margins (defined as \>2cm \[or \>1cm with clear histologic evaluation\]) in the low rectum.

Secondary

MeasureTime frameDescription
Access Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeOperatively1\. Access measured by surgeon usability questionnaire.
Visibility Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeOperatively2\. Visibility measured by surgeon usability questionnaire
Maneuverability Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeOperatively3\. Maneuverability measured by surgeon usability questionnaire Question: Maneuverability of Radial reload during the procedure was adequate

Countries

United States

Participant flow

Participants by arm

ArmCount
Covidien Radial Reload Stapler With Tri-Staple Technology
Covidien Radial Reload Stapler with Tri-Staple Technology in laparoscopic low anterior resection or proctosigmoidectomy
8
Total8

Baseline characteristics

CharacteristicCovidien Radial Reload Stapler With Tri-Staple Technology
Age, Continuous66.6 years
STANDARD_DEVIATION 10.8
Body Mass Index (BMI)27.0 kg/m2
STANDARD_DEVIATION 4.5
Ethnicity (NIH/OMB)
Hispanic or Latino
0 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
8 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants
Height165.0 centimeters
STANDARD_DEVIATION 11.9
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
1 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
7 Participants
Sex: Female, Male
Female
6 Participants
Sex: Female, Male
Male
2 Participants
Weight73.9 kilograms
STANDARD_DEVIATION 16.4

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
— / —
other
Total, other adverse events
2 / 8
serious
Total, serious adverse events
4 / 8

Outcome results

Primary

The Ability to Achieve Adequate Distal Margins (Defined as >2cm [or >1cm With Clear Histologic Evaluation]) in the Low Rectum. The Reported Value Represents the Number of Participants in Whom the Criteria Was Met

The ability to achieve adequate distal margins (defined as \>2cm \[or \>1cm with clear histologic evaluation\]) in the low rectum.

Time frame: Operative

ArmMeasureValue (NUMBER)
Covidien Radial Reload Stapler With Tri-Staple TechnologyThe Ability to Achieve Adequate Distal Margins (Defined as >2cm [or >1cm With Clear Histologic Evaluation]) in the Low Rectum. The Reported Value Represents the Number of Participants in Whom the Criteria Was Met7 participants
Primary

The Surgeon's Ability to Achieve a Staple Line at the Desired Level of the Rectum. The Reported Value Represents the Number of Participants in Whom the Criteria Was Met

The surgeon's ability to achieve a staple line at the desired level of the rectum.

Time frame: Operative

ArmMeasureValue (NUMBER)
Covidien Radial Reload Stapler With Tri-Staple TechnologyThe Surgeon's Ability to Achieve a Staple Line at the Desired Level of the Rectum. The Reported Value Represents the Number of Participants in Whom the Criteria Was Met6 participants
Secondary

Access Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly Agree

1\. Access measured by surgeon usability questionnaire.

Time frame: Operatively

ArmMeasureGroupValue (NUMBER)
Covidien Radial Reload Stapler With Tri-Staple TechnologyAccess Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeRadial Reload (RR) easy to place in pelvis62.5 % of cases surgeon agree/strongly agree
Covidien Radial Reload Stapler With Tri-Staple TechnologyAccess Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeRR was easy to get low in the pelvis87.5 % of cases surgeon agree/strongly agree
Covidien Radial Reload Stapler With Tri-Staple TechnologyAccess Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeRR was easy to place in the colon and the rectum50 % of cases surgeon agree/strongly agree
Covidien Radial Reload Stapler With Tri-Staple TechnologyAccess Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeWas the rectum contained in device after clamping50 % of cases surgeon agree/strongly agree
Covidien Radial Reload Stapler With Tri-Staple TechnologyAccess Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeRR retained an adequate amount of tissue75 % of cases surgeon agree/strongly agree
Covidien Radial Reload Stapler With Tri-Staple TechnologyAccess Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeWas the rectum transected with one firing12.5 % of cases surgeon agree/strongly agree
Secondary

Maneuverability Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly Agree

3\. Maneuverability measured by surgeon usability questionnaire Question: Maneuverability of Radial reload during the procedure was adequate

Time frame: Operatively

ArmMeasureValue (NUMBER)
Covidien Radial Reload Stapler With Tri-Staple TechnologyManeuverability Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly Agree62.5 % of cases surgeon agree/strongly agree
Secondary

Visibility Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly Agree

2\. Visibility measured by surgeon usability questionnaire

Time frame: Operatively

ArmMeasureGroupValue (NUMBER)
Covidien Radial Reload Stapler With Tri-Staple TechnologyVisibility Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeVisibility was adequate when RR was used87.5 % of cases surgeon agree/strongly agree
Covidien Radial Reload Stapler With Tri-Staple TechnologyVisibility Measured by Surgeon Usability Questionnaire. The Reported Values Represent Percentage of Cases Surgeon Agree/Strongly AgreeDid the instrument impede the visibility0 % of cases surgeon agree/strongly agree