Skip to content

Sparing of Organs at Risk in High Dose Rate Brachytherapy

Prospective Study on the Sparing of Organs at Risk in High Dose Rate Brachytherapy for Cervix Cancer

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01681342
Enrollment
24
Registered
2012-09-07
Start date
2011-06-30
Completion date
2013-02-28
Last updated
2013-07-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cervical Carcinoma Stage IB to IV

Keywords

stade Ib to IV cervix cancer, ambulatory high dose rate brachytherapy

Brief summary

Cervix carcinoma is a common malignancy. Radiation therapy still remains a major treatment for patients with carcinoma cervix. Conventional treatment with radiation therapy includes a combination of external beam radiation therapy and intracavitary treatment. Low dose rate intracavitary brachytherapy treatment is already well studied. But high dose rate brachytherapy is a relatively new alternative. In brachytherapy, major developments have been made in the integration of 3D imaging and computerized 3D treatment planning. Medical imaging improvements allowed for better definition of tumoral volumes and organs at risk. The GYN GEC-ESTRO published recommendations on the 3D imaging for better characterization of these volumes. Improvements in CT-SCan and lately in RMN had lead to a better definition of volums of interest (tumor and his extensions and organs at risk : bladder, rectum, sigmoidis, small bowels). RMN is the imaging standard in the evaluation of tumoral extension in cervix cancer. However its use is not easy in many brachytherapy departments. This study will evaluate the feasibility and sparing of organs at risk for high dose rate brachytherapy if volume delineation is done at each of the two sessions performed with 3D RMN.

Detailed description

After 60 Gy are delivered with Intensity Modulated Radiation Therapy (IMRT), the brachytherapy in high dose rate will deliver 15 Gy to the CTVhr (high risk CTV) in two sessions. A clinical examination and an RMN are performed at the end of the external radiation to evaluate the residual tumoral volume. Two HDR brachytherapy sessions are then performed. During the first session, a CT-Scan and an RMN will be performed after the fletcher application. A second CT-Scan will be performed during the second treatment session to create new volumes and to improve organs at risk sparing.

Interventions

None listed

Sponsors

Centre Oscar Lambret
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* Cervix carcinoma stage Ib to IV (FIGO) * OMS \< 2 * Tomography by positron emission and/or chirurgical staging before the external radiotherapy * RMN before the starting of treatment and at the end af external radiotherapy * Patient information * Validation of the indication af high dose rate brachytherapy * External radiation therapy (60 Gy with IMRT)

Exclusion criteria

* No external radiation therapy * Surgery in the 4 weeks before before the inclusion * Prior pelvic radiation therapy * intestinal inflammatory disease or active pathology * active infection or severe pathology didn't allow the treatment * Prior carcinoma in the last 5 years (except cutaneous carcinoma or in situ carcinoma) * Inclusion in another clinical trial

Design outcomes

Primary

MeasureTime frameDescription
Evaluation of the sparing of organs at risk with a delineation at each session and the CTVhr volume modificationAt 8 weeks of external radiotherapyTo record the irradiated volumes modifications of each OAR at each session and the CTV volume modification.

Secondary

MeasureTime frameDescription
Evaluation of medical imaging with CT-Scan and RMN for cervix cancerAt 8 weeks of external radiotherapy* Interest of RMN sequences Water and T2 for the definition of volumes * Evaluation of imaging registration on the planning treatment system based on the brachytherapy applicator for the precision of volumes delineation * Evaluate the interest of TDM and RMN for volumes delineation

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026