Paroxysmal Atrial Fibrillation
Conditions
Keywords
PAF
Brief summary
In this prospective randomized study, we aim to compare the rate of PV reconnection following PVAI performed at different energy settings (30 Watts vs 40 Watts) where dormant PV conduction will be unmasked by adenosine-provocation.
Detailed description
Background: The efficiency of catheter ablation in drug-refractory atrial fibrillation (AF) is compromised by high incidence of post-ablation AF recurrences requiring multiple ablation procedures (1). Post-PVAI (pulmonary vein antrum isolation) AF recurrence is mostly due to reconnection of the previously isolated PVs (2). Earlier studies have revealed that elimination of dormant PV conduction revealed by adenosine-provocation ensures better outcome as reconnection mostly happens due to presence of incompletely ablated tissue and identification and complete ablation decrease chance of recurrence (1). Adenosine is specifically chosen for induction of triggers because it is known to transiently or permanently re-establish left atrium-pulmonary vein (LA-PV) conduction after apparently successful PV isolation (3). Datino et al have demonstrated in the canines that adenosine selectively hyperpolarizes the PVs by increasing inward rectifier potassium (K+) current and restores excitability (4). As incompletely ablated tissue can potentially cause AF recurrence, the depth and extension of the lesion are crucial factors in determining the success-rate of ablation; these in turn are directly influenced by catheter type and the radio-frequency (RF) energy settings (5). In a previous study, Matiello et al have reported cooled-tip catheter at 40w setting to be more effective in preventing recurrence than that with 30w setting (5). However, none of the earlier studies have examined the rate of PV reconnection when AF ablation is done at different power settings using open-irrigated catheters after the dormant sites are revealed by adenosine-challenge. Hypothesis: Use of higher wattage during ablation before and after adenosine-challenge is associated with lower rate of PV reconnection.
Interventions
All patients will undergo PVAI and ablation of the posterior wall of the LA using an open-irrigated ablation catheter and under general anesthesia. After PV isolation is achieved, all will undergo PVAI followed by adenosine provocation test with 24 mg of adenosine to check for PV reconnection. Upon identification, additional RF energy would be used to ablate those sites (that were revealed by adenosine-provocation).
Sponsors
Study design
Eligibility
Inclusion criteria
1. Age ≥ 18 years 2. Patients presenting with drug-refractory PAF undergoing first ablation 3. Ability to understand and provide signed informed consent
Exclusion criteria
1. Previous catheter ablation or MAZE procedure in left atrium 2. Reversible causes of atrial arrhythmia such as hyperthyroidism, sarcoidosis, pulmonary embolism etc
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| AF recurrence | 1 year | Recurrence of AF due to PV reconnection AF recurrence is defined as any episode of AF/AT (atrial tachycardia) longer than 30 seconds will be considered as recurrence. Episodes that occur during the first 3 months of the procedure (blanking period) will not be considered as recurrence. |
Countries
United States