Skip to content

Prospective, Multicenter Trial to Investigate the Safety and Efficacy of Percutaneous Tibial Nerve Stimulation for the Treatment of Fecal Incontinence

A Prospective, Multicenter Trial to Investigate the Safety and Efficacy of Percutaneous Tibial Nerve Stimulation for the Treatment of Fecal Incontinence

Status
Terminated
Phases
Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01666405
Enrollment
30
Registered
2012-08-16
Start date
2012-08-31
Completion date
2015-04-30
Last updated
2015-10-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Fecal Incontinence

Keywords

Fecal Incontinence, Bowel Incontinence

Brief summary

The purpose of this study is to determine the effectiveness of percutaneous tibial nerve stimulation (PTNS) therapy with the Urgent® PC Neuromodulation System (Uroplasty, Inc., Minnetonka, MN, USA) for the treatment of fecal incontinence (FI).

Detailed description

Pilot Study

Interventions

DEVICEUrgent(R) PC Neuromodulation System

The Urgent PC Neuromodulation System (Uroplasty, Inc., Minnetonka, MN, USA), device, is an easily administered neuromodulation system designed to deliver retrograde access to the sacral nerve through percutaneous electrical stimulation of the tibial nerve. This method of treatment is referred to as percutaneous tibial nerve stimulation (PTNS).

Sponsors

Uroplasty, Inc
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient history of chronic FI of more than staining for at least 6 months; staining defined as less than the size of a 25¢ piece (quarter) * Patient reported and/or failed ≥ 2 conservative therapies (e.g., diet/fiber modification, anti-diarrheal medication, pelvic floor muscle training, biofeedback, medical management, etc.)

Exclusion criteria

* Pregnancy or intention to become pregnant during the course of the study * Implanted electro-medical device (i.e., pacemaker, defibrillator, deep brain stimulator, etc.) * Clinically significant neurological diseases or nerve damage impacting tibial nerve or pelvic floor function * Prone to excessive bleeding or bleeding diathesis

Design outcomes

Primary

MeasureTime frameDescription
Effectiveness18 weeksTo assess the effectiveness of PTNS by measuring the proportion of patients with ≥50% decrease in the number of fecal incontinence episodes per week based on the results of the 14-day bowel diary at 18 weeks compared to baseline
Safety18 weeksTo characterize adverse events experienced throughout the study

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026