Non-Invasive Cerenkov Luminescence Imaging of Lymphoma, Leukemia and Metastatic Lymph Nodes

Non-Invasive Cerenkov Luminescence Imaging of Lymphoma, Leukemia and Metastatic Lymph Nodes

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01664936
Enrollment
27
Registered
2012-08-14
Start date
2012-08-08
Completion date
2018-04-03
Last updated
2018-04-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Head and Neck Cancers

Keywords

18F-FDG PET/CT scan, 131I therapy, Cerenkov Luminescence Imaging, 12-050, Lymphoma, Leukemia, Metastatic Lymph Nodes

Brief summary

The purpose of this study is to see if a new way of imaging called the Cerenkov luminescence or effect that is used with a standard clinical PET/CT and/or investigation scans can be done in order to capture tumor sizes. The investigators believe endoscopies and surgical procedures could benefit from this type of imaging in the future. The Cerenkov imaging could be used as a guide for surgical resections. The purpose of this study is to use the Cerenkov light from FDG, Iodine-131 tracer sand/or other investigational tracers to image tumors and its sizes in the head, neck, breast, axillary and pelvic regions with a highly sensitive camera. The investigators will be trying to see if we can get another picture of the tumor using the Cerenkov light as part of the standard clinical scan or therapy.

Interventions

RADIATIONCerenkov emissions from the PET tracer 18F-FDG and the radiotherapeutic 131I

We will image (i) patients who are receiving a PET/CT scan for tumors in the head / neck region and (ii) patients with thyroid cancer after 131I radioablation. Two scans will be completed per patient, one of the primary tumors, as well as a 'background' scan of the contralateral side or, if tumor is there as well, of the forearm. The device to be used is an intensified charge-coupled device camera (Stanford Photonics, Palo Alto, CA) connected to a laptop PC. The camera will use a Quartz high-UV transmission 50 mm 0.8f lens. The Imaging device will be placed approximately 5 cm from the area of the patient to be imaged.

Sponsors

National Institutes of Health (NIH)
CollaboratorNIH
Memorial Sloan Kettering Cancer Center
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Participant is 18 years of age or older. * Participant is scheduled for standard clinical and/or investigational PET/CT scan or 131I therapy within the Nuclear Medicine Service at Main Hospital. * Patients must have had pathologic lymph node metastases in the neck, axillary or inguinal area (do not need to be biopsy proven) from either leukemias, lymphomas: , Head and Neck cancers (e.g. tonsillar, nasopharynx, tongue carcinoma, breast cancer or melanoma;or lymphoma or tonsillar or squamous cell carcinoma with metastases in the neck region for PET/CT imaging, or thyroid cancer for thyroid ablation therapy. Any other more infrequent cancer metastasizing with nodal metastasis in the neck, axilla and inguinal regions to cervical lymph nodes is eligible as well as the primary goal is to image pathological (i.e. hypermetabolic) lymph nodes. * Patients with hypermetabolic activity and uptake in the neck,axilla, breast and inguinal region on scan, defined visually as significant lesion suspicious for malignancy by a nuclear medicine physician or trainee. (We will include a subset of patients with normal lymph nodes during screening. This subset of patients will be imaged as a negative control for this study.)

Exclusion criteria

* Patients imaged for Cerenkov luminescence are going to be required to be in a darkened enclosure for at least 10 minutes and sit still during image acquisition, potentially covered by a dark cloth in case that the ambient light level remains too high for the ultra-sensitive camera. Any conditions that would prevent this will exclude the patients. * There are any other past medical, physiological or demographic concerns. This includes any patients with skin blemishes that are present at the dermis over the tumor, as these are of particular interest for use of this technique.

Design outcomes

Primary

MeasureTime frameDescription
feasibility of clinical Cerenkov imaging2 yearsis to assess the feasibility of clinical Cerenkov luminescence imaging using current clinical radiotracers (18F-FDG and 131I) and a highly sensitive camera.

Secondary

MeasureTime frameDescription
Correlate Cerenkov imaging2 yearssignal with uptake of the radiotracer. Cerenkov images will be correlated with images obtained from standard clinical PET/CT and scintigraphy.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 18, 2026