Skip to content

Conventional Versus Ultrasound-guided Transbronchial Needle Aspiration for the Diagnosis of Hilar/Mediastinal Lymphadenopathies

Conventional Versus Ultrasound-guided Transbronchial Needle Aspiration, Using Rapid On-site Cytological Evaluation, for the Diagnosis of Hilar/Mediastinal Enlarged Lymph Nodes: a Randomized Controlled Trial.

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01658280
Enrollment
253
Registered
2012-08-07
Start date
2012-08-31
Completion date
2015-07-31
Last updated
2016-02-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mediastinal Lymphadenopathy, Hilar Lymphadenopathy, Lymphoma, Lung Neoplasms, Sarcoidosis

Keywords

transbronchial needle aspiration, ultrasound guided transbronchial needle aspiration, sensitivity, hilar/mediastinal adenopathy

Brief summary

The main purpose of the present study is to assess whether the sensitivity of Ultrasound-guided Transbronchial Needle Aspiration (EBUS-TBNA) is superior to that of conventional TBNA in the diagnosis of hilar/mediastinal adenopathy and lung cancer staging.

Detailed description

The role of transbronchial needle aspiration (TBNA) for the diagnosis of hilar/mediastinal adenopathy and lung cancer staging is well established. However, it is a blind procedure and its diagnostic yield seems to be related to the operator experience, as well as to the size and location of lymph nodes. In the recent years, there has been increased interest in imaging-assisted TBNA and the endobronchial ultrasound has been suggested to be feasible and to improve the diagnostic yield. Another technique able to optimize the performance of transbronchial aspirations is the rapid on-site cytological examination (ROSE), allowing to assess the adequacy of samples collected. In this context, no comparative studies between standard TBNA and EBUS-TBNA have been performed. It is very important for clinical practice to definitively assess the possible superiority of EBUS-TBNA in terms of sensitivity, and to provide information regarding safety, procedural time and costs to define the best diagnostic strategy. The study is focused on 252 patients who have at least one hilar/mediastinal lymph node \> 1 cm on CT scan in at least one approachable lymph nodal station (except 2R and 2L) for which a diagnostic cyto-histological assessment is required for clinical purpose. Patients will be randomized 1:1 (control : intervention) by a computer-generated random-allocation system to undergo EBUS-TBNA or conventional TBNA. In case of failure of conventional TBNA, the operator will shift to EBUS procedure. Moreover,a subgroup analysis will be perform to assess the potential impact of lymphnode size and position on final results(univariate analysis).

Interventions

DEVICEEBUS-TBNA

Patients allocated in the intervention group will undergo EBUS-TBNA procedure, performed in a bronchoscopy suite by the same operator under conscious sedation Three needle passes for each approachable station will be performed. The samples obtained will be examined on-site by experienced blinded cytopathologist.All specimens obtained will be send to definitive cytological and histological evaluation and the final diagnosis will be collected and reported on CRFs

Sponsors

Azienda Ospedaliero, Universitaria Ospedali Riuniti
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* age ≥ 18years; * presence of at least one hilar/mediastinal adenopathy \>1 cm on short axis assessed by contrast-enhanced CT scan in at least one approachable stations other than 2R and 2L; * ability to give an informed consent.

Exclusion criteria

* presence of mediastinal adenopathy in stations 2R and 2L; * coagulopathy or bleeding diathesis that cannot be corrected; * severe refractory hypoxemia; * unstable hemodynamic status; * inability to give an informed consent.

Design outcomes

Primary

MeasureTime frameDescription
To compare the sensitivity of EBUS-TBNA and conventional TBNA in the diagnosis of hilar/mediastinal adenopathies36 monthsThe sensitivity is defined as the rate of true positive diagnoses/(true positive + false negative). Sensitivity of EBUS-TBNA will be considered superior to that of conventional TBNA if it will achieve at least a value of 90%

Secondary

MeasureTime frameDescription
Specificity of TBNA and EBUS-TBNA36 monthsSpecificity is defined as the rate of true negatives diagnoses /true negative + false positive
Sensitivity of EBUS-TBNA performed after the possible failure of traditional TBNA36 months
Number of partecipants with adverse events36 months
Costs related to each diagnostic strategy36 monthsIt will be evaluated the cost related to the whole procedure, including the possible shift to EBUS-TBNA.
Procedural time36 months

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026