Skip to content

Enable I Long-term Follow-up Study

Enable I Long-term Follow-up Study

Status
Terminated
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01636648
Enrollment
42
Registered
2012-07-10
Start date
2012-08-31
Completion date
2016-04-30
Last updated
2017-11-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Valve Insufficiency, Aortic Valve Stenosis

Keywords

Aortic Valve Replacement, Aortic Valve Bioprosthesis

Brief summary

This was a prospective, non-randomized, multi-center, non-interventional post-market study. The study was a post-market long-term follow-up study based on the same cohort of patients (148 patients) enrolled in a previous investigational study from March 2007 to December 2009 (ATS 3f Enable™ Aortic Bioprosthesis Model 6000, number S2005) involving 10 European sites. Patient follow-up took place on a yearly basis up to 10 years after the implant/enrollment. The primary objective of this study was to evaluate the safety and effectiveness of the Medtronic ATS Enable Aortic Bioprosthesis during long-term follow-up. As this was an observational study, safety and efficacy data were summarized and described. There was no statistically powered study hypothesis.

Interventions

DEVICEAortic Valve Replacement

Aortic Valve Replacement with Medtronic ATS 3f ENABLE® Aortic Bioprosthesis Model 6000

Sponsors

Medtronic Cardiac Rhythm and Heart Failure
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients who were enrolled and implanted for the ATS 3f Enable™ Aortic Bioprosthesis Model 6000, number S2005 * Patient willing to sign the new Data Release form (DRF) or Patient Informed Consent (PIC) for the post-market study (what is applicable for the study due to local requirements and regulations)

Exclusion criteria

* ATS 3f Enable™ Aortic Bioprosthesis Model 6000 was explanted * Patient died * Patient lost to follow-up * Patient withdrew consent

Design outcomes

Primary

MeasureTime frameDescription
Assess the Long-term safety of the Medtronic ATS Enable Aortic Bioprosthesis10 Years Post-ProcedureLong-term safety will be assessed by collecting following reported adverse events addressed: Migration, Valve Related Thromboembolism, Valvular thrombosis, Haemorrhage, Perivalvular Leak, Endocarditis, Hmolysis, Structural valve Deterioration, Non-Structural Dysfunction, Reoperation, Explant and Death.
Assess the Long-term Clinical Effectiveness of the Medtronic ATS Enable Aortic Bioprosthesis: NYHA Functional Classification10 Years Post-ProcedureLong-term clinical effectiveness of the Aortic Bioprosthesis will be assessed by collecting the NYHA-class of enrolled subjects over a period of time, following surgery.
Long-term Effectiveness of the Medtronic ATS Enable Aortic Bioprosthesis: Hemodynamic Performance10 Years Post-ProcedureHemodynamic performance of the Aortic Bioprosthesis will be assessed by specific echocardiography measurements

Countries

Germany, Poland, Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026