Skip to content

Evaluation of the Jarvik 2000 Left Ventricular Assist System With Post-Auricular Connector--Destination Therapy Study

Evaluation of the Jarvik 2000 Left Ventricular Assist System With Post-Auricular Connector--Destination Therapy Study

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01627821
Enrollment
350
Registered
2012-06-26
Start date
2013-02-28
Completion date
2025-03-31
Last updated
2024-03-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Keywords

Heart Failure

Brief summary

This investigation will be conducted as an interventional intention-to-treat clinical study in a population of end stage heart failure patients who meet specific inclusion and exclusion criteria. The multi-center study will be prospective, dual-armed, non-blinded (open-label) and randomized, comparing a treatment group receiving the Jarvik 2000 LVAS with Post-Auricular Connector to an active control group treated with the PMA approved Thoratec HeartMate® II LVAS for Destination Therapy.

Detailed description

Study Success for Primary Endpoint A will be established if the proportion of subjects in the Treatment Group meeting the Subject Success Criteria A, is determined to be non-inferior to that of the Control Group (at two years) according to the pre-specified statistical analysis. Subject composite success requires the subject to achieve the Effectiveness Endpoint: 1. Two year actuarial survival 2. Freedom from procedures to repair, or replace the implanted device 3. Freedom from stroke resulting in a Modified Rankin Score of \>3 at the two-year follow-up Study Success for Primary Endpoint B will be established if the proportion of subjects in the Treatment Group meeting the Subject Success Criteria B is determined to be superior to that of the Control Group (at three years) according to the pre-specified statistical analysis. Subject composite success requires the subject to achieve the Effectiveness Endpoint: 1. Three year survival 2. Freedom from the serious adverse event of drive cable or pump pocket infection

Interventions

DEVICEJarvik 2000 VAS

Jarvik 2000 LVAD

DEVICEHeartMate II

HeartMate II LVAD

Sponsors

Jarvik Heart, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

1. Cardiac transplantation ineligible. 2. Late stage heart failure in NYHA Class IIIb or IV for at least 45 of past 60 days. 3. Cardiac Index \< 2.2 L / min / m2 4. LVEF = 25% or less 5. Patients on Optimal Medical Management (OMM) as defined in Section 9.2 OR dependent on intra-aortic balloon counter-pulsation for 7 days OR other temporary (indicated for 30 days use, or less) mechanical circulatory support for 7 days, OR supported with IV inotropes for 7 days and failing to respond. 6. BSA \> 1.2 m2 and \< 2.5 m2.

Exclusion criteria

1. History of cardiac transplantation or left ventricular reduction procedure. 2. Clinical conditions, other than heart failure, which could limit survival to less than three years. 3. Cause of heart failure due to, or associated with, uncorrected thyroid disease, obstructive / restrictive cardiomyopathy, pericardial disease, amyloidosis, dermatomyositis, or active myocarditis. 4. Intolerance to anti-coagulation or anti-aggregation therapy required for post-operative therapy. 5. Known sensitivity to products of bovine origin. The Jarvik 2000 incorporates a Hemashield vascular graft. Patients with a known sensitivity to products of bovine origin should not be implanted. 6. Chronic immunosuppression.

Design outcomes

Primary

MeasureTime frameDescription
Non-inferiority to Control Group.2 yearsStudy Success for Primary Endpoint A will be established if the proportion of subjects in the Treatment Group meeting the Subject Success Criteria A, is determined to be non-inferior to that of the Control Group (at two years) according to the pre-specified statistical analysis. Subject composite success requires the subject to achieve the Effectiveness Endpoint: 1. Two year actuarial survival 2. Freedom from procedures to repair, or replace the implanted device 3. Freedom from stroke resulting in a Modified Rankin Score of \>3 at the two-year follow-up

Secondary

MeasureTime frameDescription
Serious adverse events2 yearsSerious adverse events
Quality of life measures: Questionnaire2 yearsKansas City Cardiomyopathy Questionnaire. There are 23 items. Scores from 0-100 in which a higher score indicates better quality of life.

Countries

United States

Contacts

Primary ContactRobert Jarvik, MD
clinical@jarvikheart.com212-397-3911

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026