Skip to content

New Fabric Attenuation Device in Endovascular Interventional Radiology II (PREFER II)

Prospective Randomized Evaluation of a New Fabric Attenuation Device in Endovascular Interventional Radiology II (PREFER II)

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01611454
Acronym
PREFER-II
Enrollment
106
Registered
2012-06-05
Start date
2011-05-31
Completion date
2011-08-31
Last updated
2021-11-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Occupational Exposure to Radiation

Keywords

Occupational Exposure to Radiation

Brief summary

The PREFER II trial primary objective of the trial is to show how much radiation attenuation is provided by XPF thyroid collars in absolute and relative terms.

Detailed description

The PREFER II trial has three main objectives. The primary objective of the trial is to show how much radiation attenuation is provided by XPF thyroid collars in absolute and relative terms. The secondary objective of the study is to measure and compare the amount of radiation that interventional radiologists are exposed to per case in an interventional suite setting using FDA approved XPF thyroid collars or standard 0.5 mm Pb equivalent thyroid collars. The third objective is to assess the operator comfort wearing the XPF protection devices. In order to achieve these objectives, measurements will be performed in 150 consecutive interventional procedures requiring C-arm fluoroscopy performed at BCVI. A prospective randomization will be performed, assigning participants to wear their own standard 0.5 mm Pb equivalent thyroid collar or to wear the FDA approved XPF thyroid collar. Radiation exposure will be monitored with 2 radiation detectors (TLDs, one inside and one outside the thyroid collar) which the participant is required to wear. After each procedure the participant will be asked to rate the comfort of wearing the devices on a scale from 1 to 100.

Interventions

DEVICEXPF thyroid collar

Interventionalist wear the experimental (XPF) thyroid collar during fluoroscopy guided interventions.

DEVICEStandard 0.5mm lead equivalent thyroid collar

Interventionalist wear a standard 0.5mm lead equivalent thyroid collar during the same type of comparator fluoroscopy guided interventions. Comparator arm uses same type of lead thyroid collar but the XPF under investigation.

Sponsors

Baptist Health South Florida
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Interventional Radiologists practicing in Baptist Cardiac & Vascular Institute * consecutive endovascular procedure requiring C-arm fluoroscopy

Exclusion criteria

* Interventional Neuroradiologists and Interventional Cardiologists will not be included in this study.

Design outcomes

Primary

MeasureTime frameDescription
Percentage Change1 dayRadiation attenuation. The null hypothesis is that the XPF thyroid collar is equal to the standard 0.5mm Pb lead equivalent thyroid collar with regard to radiation attenuation/transmission in relative (%) terms. The alternative hypothesis is that the XPF thyroid collar is superior or inferior to the standard thyroid collar. Based on our results obtained during the 60 procedures (PREFER trial), 150 procedures are required to demonstrate a significant difference with an alpha level of 5% and a power of 80%. Radiation attenuation percentage is measure by interrogation of the lead attenuates X-rays counter required to be used in all interventional radiology clinical procedures by each physician operator. The interrogation is done by measuring the energy imparted per unit mass in the counter wore by ionizing radiation to matter at the specified point. The International System of Units (SI) unit of absorbed dose is the joule per kilogram.

Secondary

MeasureTime frameDescription
Wearing Comfort of the Collar on a Scale From 0-100.1 dayOperators are asked directly after each procedure to rate the wearing comfort, graded worst to best. 0 means low comfort (worse outcome) and 100 is the best comfort level (best outcome) with wearing the collar.
Radiation Exposure (uSv) for for Both the Thyroid and Equivalent Collars1 day(day 1) Operators are asked directly after each procedure to rate the wearing comfort Radiation exposure will be monitored with radiation detectors (TLDs, 2 attached to the collar) which the participant is required to wear. Exposure is measured as the energy imparted per unit mass by ionizing radiation to the matter at the specified time of the procedure. The International System of Units (SI) unit of absorbed dose is the joule per kilogram. The special name for this unit is the gray (Gy). For purposes of radiation protection and assessing dose or risk to humans in general terms, the quantity normally calculated is the mean absorbed dose in an organ or tissue.
Radiation Exposure (uSv) for XPF Caps and the Equivalent Caps1 day(day 1) Operators are asked directly after each procedure to rate the wearing comfort Radiation exposure will be monitored with radiation detectors, which the participant is required to wear. Exposure is measured as the energy imparted per unit mass by ionizing radiation to the matter at the specified time of the procedure. The International System of Units (SI) unit of absorbed dose is the joule per kilogram. The special name for this unit is the gray (Gy). For purposes of radiation protection and assessing dose or risk to humans in general terms, the quantity normally calculated is the mean absorbed dose in an organ or tissue.

Countries

United States

Participant flow

Participants by arm

ArmCount
XPF Thyroid Collar
Administration of the XPF Thyroid Collar. XPF thyroid collar: Interventionalist wear the experimental (XPF) thyroid collar during fluoroscopy guided interventions.
58
Equivalent Collar
Administration of the Standard 0.5mm lead-equivalent thyroid collar. Standard 0.5mm lead equivalent thyroid collar: Interventionalist wear a standard 0.5mm lead equivalent thyroid collar during fluoroscopy guided interventions.
48
Total106

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudyLack of Efficacy1810

Baseline characteristics

CharacteristicEquivalent CollarXPF Thyroid CollarTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
22 Participants22 Participants44 Participants
Age, Categorical
Between 18 and 65 years
26 Participants36 Participants62 Participants
Age, Continuous50 Year
STANDARD_DEVIATION 25
50 Year
STANDARD_DEVIATION 25
50 Year
STANDARD_DEVIATION 25
Region of Enrollment
United States
48 participants58 participants106 participants
Sex: Female, Male
Female
24 Participants26 Participants50 Participants
Sex: Female, Male
Male
24 Participants32 Participants56 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 580 / 48
other
Total, other adverse events
0 / 580 / 48
serious
Total, serious adverse events
0 / 580 / 48

Outcome results

Primary

Percentage Change

Radiation attenuation. The null hypothesis is that the XPF thyroid collar is equal to the standard 0.5mm Pb lead equivalent thyroid collar with regard to radiation attenuation/transmission in relative (%) terms. The alternative hypothesis is that the XPF thyroid collar is superior or inferior to the standard thyroid collar. Based on our results obtained during the 60 procedures (PREFER trial), 150 procedures are required to demonstrate a significant difference with an alpha level of 5% and a power of 80%. Radiation attenuation percentage is measure by interrogation of the lead attenuates X-rays counter required to be used in all interventional radiology clinical procedures by each physician operator. The interrogation is done by measuring the energy imparted per unit mass in the counter wore by ionizing radiation to matter at the specified point. The International System of Units (SI) unit of absorbed dose is the joule per kilogram.

Time frame: 1 day

ArmMeasureValue (MEAN)Dispersion
XPF Thyroid CollarPercentage Change79.7 percentage changeStandard Deviation 25.8
Equivalent CollarPercentage Change71.9 percentage changeStandard Deviation 34.2
Secondary

Radiation Exposure (uSv) for for Both the Thyroid and Equivalent Collars

(day 1) Operators are asked directly after each procedure to rate the wearing comfort Radiation exposure will be monitored with radiation detectors (TLDs, 2 attached to the collar) which the participant is required to wear. Exposure is measured as the energy imparted per unit mass by ionizing radiation to the matter at the specified time of the procedure. The International System of Units (SI) unit of absorbed dose is the joule per kilogram. The special name for this unit is the gray (Gy). For purposes of radiation protection and assessing dose or risk to humans in general terms, the quantity normally calculated is the mean absorbed dose in an organ or tissue.

Time frame: 1 day

Population: XPF thyroid collar and the equivalent collar are combined under one outcome measure as the outcome measure is comparing the arms and not as individual measures.

ArmMeasureValue (MEAN)Dispersion
XPF Thyroid CollarRadiation Exposure (uSv) for for Both the Thyroid and Equivalent Collars272.3 GyStandard Deviation 373.3
Equivalent CollarRadiation Exposure (uSv) for for Both the Thyroid and Equivalent Collars98.2 GyStandard Deviation 203.1
Secondary

Radiation Exposure (uSv) for XPF Caps and the Equivalent Caps

(day 1) Operators are asked directly after each procedure to rate the wearing comfort Radiation exposure will be monitored with radiation detectors, which the participant is required to wear. Exposure is measured as the energy imparted per unit mass by ionizing radiation to the matter at the specified time of the procedure. The International System of Units (SI) unit of absorbed dose is the joule per kilogram. The special name for this unit is the gray (Gy). For purposes of radiation protection and assessing dose or risk to humans in general terms, the quantity normally calculated is the mean absorbed dose in an organ or tissue.

Time frame: 1 day

Population: XPF caps and the equivalent caps are combined under one outcome measure as the outcome measure is comparing the arms and not as individual measures.

ArmMeasureValue (MEAN)Dispersion
XPF Thyroid CollarRadiation Exposure (uSv) for XPF Caps and the Equivalent Caps224.1 GyStandard Deviation 266.1
Equivalent CollarRadiation Exposure (uSv) for XPF Caps and the Equivalent Caps48.1 GyStandard Deviation 124.7
Secondary

Wearing Comfort of the Collar on a Scale From 0-100.

Operators are asked directly after each procedure to rate the wearing comfort, graded worst to best. 0 means low comfort (worse outcome) and 100 is the best comfort level (best outcome) with wearing the collar.

Time frame: 1 day

ArmMeasureValue (MEAN)Dispersion
XPF Thyroid CollarWearing Comfort of the Collar on a Scale From 0-100.85.0 score on a scaleStandard Deviation 8.8
Equivalent CollarWearing Comfort of the Collar on a Scale From 0-100.83.3 score on a scaleStandard Deviation 13.1

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026