Lung Deflation in Pediatric Subclavian Vein Catheterization

The Effect of Lung Deflation on the Position of the Pleura in Mechanically Ventilated Infants During Subclavian Vein Cannulation: an Ultrasound Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01608503
Acronym
SCVLD
Enrollment
41
Registered
2012-05-31
Start date
2011-05-31
Completion date
2012-04-30
Last updated
2013-04-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pediatric Subclavian Vein Catheterization

Keywords

subclavian vein, ultrasound, distance between the subclavian vein and the lung

Brief summary

The subclavian vein (SCV) is a preferred site for placement of central venous catheter. However, pneumothorax is a major concern during subclavian venous catheterization. Lung deflation, by decreasing lung volume, may reduce the risk of pneumothorax by increasing the distance between the pleura and the SCV. The investigators evaluated the effect of lung deflation on the relative position between the pleura and the line of the imaginary needle pathway during supraclavicular and infraclavicular approach to the subclavian vein (SCV) using ultrasonography.

Interventions

PROCEDURElung deflation

lung was deflated during respiration cycle

PROCEDURElung inflation

lung was inflated during respiratory cycle

Sponsors

Seoul National University Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SUPPORTIVE_CARE
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
No minimum to 1 Years
Healthy volunteers
No

Inclusion criteria

* Pediatric patients who were scheduled for elective operation under general anesthesia * Neonates (0 \ 1 mo), Infants (1 mo \ 1 yr)

Exclusion criteria

* Structural anomalies of the chest wall * History of lung and chest wall operations * Prior central venous catheterization * Upper respiratory tract infection, or pneumonia within 2 weeks

Design outcomes

Primary

MeasureTime frameDescription
The distance between the pleura and the line of the imaginary needle pathway (DPI)Within 5 minutesThe ultra-sonography probe was adjusted to obtain an image containing the long-axis cross section of SCV, the pleura, the clavicle, and the first rib. Images were recorded by the same physician during whole respiratory cycle with the probe held in the identical position. Imaginary lines for supraclavicular and infraclavicular approach were drawn, and distances from the pleura were measured. If the pleura touched the INP, the distance was recorded as positive value. If the pleura did not touch the INP, the distance was recorded as negative value.

Secondary

MeasureTime frameDescription
The incidence of pleural movement over the imaginary needle pathwayWithin 5 minutesIf the pleura touched the imaginary needle pathway, the incidence was checked.