Colorectal Neoplasms
Conditions
Keywords
adenoma detection, screening colonoscopy, water exchange method, chromoendoscopy
Brief summary
Adenoma detection rate (ADR) is a quality indicator of colonoscopy performed for colorectal cancer screening. Population studies have shown that traditional air colonoscopy fails to eliminate post screening colonoscopy cancers or cancer mortality in the proximal colon. The investigators aim to establish the superior effectiveness of combining chromoendoscopy with the water exchange method in detecting more proximal diminutive adenomas during screening colonoscopy in sedated Veterans. An improved adenoma detection rate associated with optical colonoscopy will minimize the risk of missed lesions. The improvement may translate into a remedy for the limitations of screening colonoscopy in the proximal colon, e.g. a higher adenoma detection rate may minimize the burden of post screening colonoscopy interval colorectal cancers among the veteran population.
Detailed description
1. Design: Prospective, single center, patient blinded, randomized controlled trial 2. Methods: Colonoscopy with traditional air insufflation, water exchange or water exchange plus indigocarmine to aid insertion of colonoscope; split dose bowel preparation; all patients will receive sedation; assessment of serum electrolytes level before and after colonoscopy 1. Control method: Traditional air insufflation method. 2. Study methods: * Water exchange method. * Water method combined with chromoendoscopy (0.008% indigo carmine). 3. Population to be studied Veterans between age 50 and 75 referred for first time screening colonoscopy 4. Unit(s) of analysis 1. Primary outcome: overall adenoma detection rate. 2. Secondary outcomes: patient demographic variable and procedure related measures. 5. Sampling strategy: all Veterans referred for screening colonoscopy will be offered enrollment in the study. 1. Sample size calculation. A total of 480 subjects will be recruited and randomized with 160 in each group. 5\. Subject recruitment: patients referred for screening colonoscopy come from three sources. 6\. Description of base population and groups to be studied and method of randomization. Veterans between age 50 and 75 referred for first time screening colonoscopy. After informed consent, assignment to control or study arm based on computer generated random number codes stored in pre-arranged opaque envelopes.
Interventions
0.008% indigo carmine in water is used as a surface contrast agent to enhance visualization of diminutive polyps (adenoma) during screening colonoscopy
Residual pocket of air will be suctioned. Water is infused using a peristaltic pump to facilitate scope advancement until the cecum is reached. Dirty water will be suctioned and clean water is infused. Air will not be insufflated until the cecum is reached. Residual water is suctioned and air insufflated on scope withdrawal to facilitate biopsy and removal of lesions.
Residual pocket of air will be suctioned. Water with 0.008% indigocarmine is infused using a peristaltic pump to facilitate scope advancement until the cecum is reached. Dirty water will be suctioned and clean water is infused. Air will not be insufflated until the cecum is reached. Residual water is suctioned and air insufflated on scope withdrawal to facilitate biopsy and removal of lesions
The colonoscope is inserted gently and advanced slowly using minimal air insufflation, if necessary, the assistant will provide abdominal compression or the patient's position will be changed to facilitate scope passage. The scope is inserted until the cecum is reached. Air is insufflated on scope withdrawal for visualization and water irrigation is used to remove any adherent feces covering the mucosa. Biopsy or polypectomy is performed where indicated.
Sponsors
Study design
Eligibility
Inclusion criteria
* asymptomatic Veterans scheduled for first time screening colonoscopy and agree to be randomized will be enrolled.
Exclusion criteria
* patients who decline to be randomized, non screening cases.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Number of Participants With Detected Proximal Diminutive (<10 mm) Adenoma Detection Rate | 36 months | Proximal diminutive adenoma detection rate (ADR) in screening colonoscopy performed with the unusual air method, versus the water (exchange) method and with dye added to the water (exchange) method |
Countries
United States
Participant flow
Participants by arm
| Arm | Count |
|---|---|
| Water (Exchange) Method Residual pocket of air will be suctioned. Water is infused using a peristaltic pump to facilitate scope advancement until the cecum is reached. Dirty water will be suctioned and clean water is infused. Air will not be insufflated until the cecum is reached. Residual water is suctioned and air insufflated on scope withdrawal to facilitate biopsy and removal of lesions.
water (exchange) method: Residual pocket of air will be suctioned. Water is infused using a peristaltic pump to facilitate scope advancement until the cecum is reached. Dirty water will be suctioned and clean water is infused. Air will not be insufflated until the cecum is reached. Residual water is suctioned and air insufflated on scope withdrawal to facilitate biopsy and removal of lesions. | 161 |
| Water (Exchange) Plus Dye Method Residual pocket of air will be suctioned. Water with 0.008% indigocarmine is infused using a peristaltic pump to facilitate scope advancement until the cecum is reached. Dirty water will be suctioned and clean water is infused. Air will not be insufflated until the cecum is reached. Residual water is suctioned and air insufflated on scope withdrawal to facilitate biopsy and removal of lesions
Indigo carmine: 0.008% indigo carmine in water is used as a surface contrast agent to enhance visualization of diminutive polyps (adenoma) during screening colonoscopy
water (exchange) plus dye method: Residual pocket of air will be suctioned. Water with 0.008% indigocarmine is infused using a peristaltic pump to facilitate scope advancement until the cecum is reached. Dirty water will be suctioned and clean water is infused. Air will not be insufflated until the cecum is reached. Residual water is suctioned and air insufflated on scope withdrawal to facilitate biopsy and removal of lesions | 160 |
| Air Method The colonoscope is inserted gently and advanced slowly using minimal air insufflation, if necessary, the assistant will provide abdominal compression or the patient's position will be changed to facilitate scope passage. The scope is inserted until the cecum is reached. Air is insufflated on scope withdrawal for visualization and water irrigation is used to remove any adherent feces covering the mucosa. Biopsy or polypectomy is performed where indicated.
air method: The colonoscope is inserted gently and advanced slowly using minimal air insufflation, if necessary, the assistant will provide abdominal compression or the patient's position will be changed to facilitate scope passage. The scope is inserted until the cecum is reached. Air is insufflated on scope withdrawal for visualization and water irrigation is used to remove any adherent feces covering the mucosa. Biopsy or polypectomy is performed where indicated. | 159 |
| Total | 480 |
Baseline characteristics
| Characteristic | Water (Exchange) Method | Water (Exchange) Plus Dye Method | Air Method | Total |
|---|---|---|---|---|
| Age, Categorical <=18 years | 0 Participants | 0 Participants | 0 Participants | 0 Participants |
| Age, Categorical >=65 years | 59 Participants | 55 Participants | 53 Participants | 167 Participants |
| Age, Categorical Between 18 and 65 years | 102 Participants | 105 Participants | 106 Participants | 313 Participants |
| BMI | 29.6 kg/m^2 STANDARD_DEVIATION 4.1 | 29.2 kg/m^2 STANDARD_DEVIATION 4.3 | 29.4 kg/m^2 STANDARD_DEVIATION 4.3 | 29.4 kg/m^2 STANDARD_DEVIATION 4.2 |
| Ethnicity (NIH/OMB) Hispanic or Latino | 14 Participants | 12 Participants | 11 Participants | 37 Participants |
| Ethnicity (NIH/OMB) Not Hispanic or Latino | 146 Participants | 147 Participants | 148 Participants | 441 Participants |
| Ethnicity (NIH/OMB) Unknown or Not Reported | 1 Participants | 1 Participants | 0 Participants | 2 Participants |
| Region of Enrollment United States | 161 Participants | 160 Participants | 159 Participants | 480 Participants |
| Sex: Female, Male Female | 22 Participants | 19 Participants | 24 Participants | 65 Participants |
| Sex: Female, Male Male | 139 Participants | 141 Participants | 135 Participants | 415 Participants |
Adverse events
| Event type | EG000 affected / at risk | EG001 affected / at risk | EG002 affected / at risk |
|---|---|---|---|
| deaths Total, all-cause mortality | 0 / 161 | 0 / 160 | 0 / 159 |
| other Total, other adverse events | 0 / 161 | 0 / 160 | 0 / 159 |
| serious Total, serious adverse events | 4 / 161 | 3 / 160 | 1 / 159 |
Outcome results
Number of Participants With Detected Proximal Diminutive (<10 mm) Adenoma Detection Rate
Proximal diminutive adenoma detection rate (ADR) in screening colonoscopy performed with the unusual air method, versus the water (exchange) method and with dye added to the water (exchange) method
Time frame: 36 months
| Arm | Measure | Group | Value (NUMBER) |
|---|---|---|---|
| Water (Exchange) Method | Number of Participants With Detected Proximal Diminutive (<10 mm) Adenoma Detection Rate | Proximal ADR | 86 participants |
| Water (Exchange) Method | Number of Participants With Detected Proximal Diminutive (<10 mm) Adenoma Detection Rate | Serrated Lesion | 38 participants |
| Water (Exchange) Plus Dye Method | Number of Participants With Detected Proximal Diminutive (<10 mm) Adenoma Detection Rate | Serrated Lesion | 42 participants |
| Water (Exchange) Plus Dye Method | Number of Participants With Detected Proximal Diminutive (<10 mm) Adenoma Detection Rate | Proximal ADR | 89 participants |
| Air Method | Number of Participants With Detected Proximal Diminutive (<10 mm) Adenoma Detection Rate | Serrated Lesion | 18 participants |
| Air Method | Number of Participants With Detected Proximal Diminutive (<10 mm) Adenoma Detection Rate | Proximal ADR | 83 participants |