Skip to content

Radial Strain ECHO-Guided Implantation of Cardiac Resynchronization Therapy

Radial Strain Imaging-Guided Lead Placement for Improving Response to Cardiac Resynchronization Therapy in Patients With Ischemic Cardiomyopathy: A Randomized Clinical Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01603706
Acronym
RAISE-CRT
Enrollment
172
Registered
2012-05-22
Start date
2012-05-31
Completion date
2017-10-31
Last updated
2017-10-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ischemic Cardiomyopathy

Keywords

Heart failure, Cardiac Resynchronization Therapy, CRT, Radial strain echocardiography, Ischemic cardiomyopathy

Brief summary

The purpose of this study is to evaluate the use of radial strain imaging using speckle tracking analysis to predict the response to CRT in patients with ischemic cardiomyopathy (ICMP) with NYHA functional class 2-4 heart failure and a standard guideline-based CRT indication. Thus assessing the value of lead localization determined by radial strain imaging in a prospective, randomized manner.

Detailed description

In this study we propose to evaluate the utility of radial strain imaging using speckle tracking to predict the response to CRT in patients with ischemic cardiomyopathy (ICMP) with NYHA functional class 2-4 heart failure and a standard guideline-based CRT indication, and to determine the value of lead localization determined by radial strain imaging in a prospective, randomized manner. We will compare two randomized groups of CRT recipients implanted with CRT-D systems. In the control group, implantation will be performed in the usual manner and the lead will be placed at the discretion of the implanting physician, preferably at posterolateral LV sites . In the study group, leads will be placed in areas of latest contraction that lack significant scar, as determined by speckle tracking imaging. The primary outcome measure for comparison between the 2 groups will be echocardiographic response (as assessed by percent reduction in left ventricular end systolic volumes) at 6 months post-implantation. In addition, clinical response parameters will also be measured as secondary end points. We hypothesize that 1) patients showing greater dyssynchrony and/or discoordination index with speckle tracking will derive a significantly greater response to cardiac resynchronization therapy; and 2) patients allocated to the image-guided LV lead placement group will derive a significantly greater response to CRT than patients in the non- guided implantation (control) group. If radial strain imaging proves useful for improving the CRT response rate and identification of patients likely to respond, it will have important clinical and economic implications by improving individual outcomes and more effective utilization of constrained health care resources. Furthermore, if echo-guided lead implantation proves to be effective in reducing the relatively large non-response rate to cardiac resynchronization therapy, it will likely result in increased device utilization among eligible heart failure patients. Specific Aims Aim #1: To show that in patients with ischemic cardiomyopathy, implantation of a CRT LV lead guided by radial strain imaging results in a significantly greater echocardiographic and clinical response to cardiac resynchronization therapy compared with conventional implantation techniques. Aim #2: To show that speckle tracking strain data can be used to identify the degree of echocardiographic response to CRT, using both dyssynchrony (time to peak strain ) and discoordination indices. Aim #3: The Paieon substudy will comprise 40 patients enrolled at 3 centers, for whom additional information mechanical dyssynchrony, using the Paieon CardioGuide motion map, will be collected during device implantation as detailed below The primary aim of the study is to relate data of mechanical dyssynchrony obtained from angiography through the Paieon CardioGuide motion map to dyssynchrony data obtained from the echocardiogram. The dyssynchrony data will not be available to the treating physicians and will not be used to direct the LV lead location.

Interventions

PROCEDUREEcho guided implantation group

Lead placement according echo strain imaging result

Sponsors

Tel-Aviv Sourasky Medical Center
CollaboratorOTHER_GOV
Rabin Medical Center
CollaboratorOTHER
Rambam Health Care Campus
CollaboratorOTHER
Kaplan Medical Center
CollaboratorOTHER
Soroka University Medical Center
CollaboratorOTHER
Mayo Clinic
CollaboratorOTHER
Sheba Medical Center
Lead SponsorOTHER_GOV

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients with ischemic CMP based on evidence of prior MI by history, coronary angiography/revascularization or imaging * AHA ACC or ESC EHRA Guideline-based indication (Class I or II) for CRT and NYHA class II-IV heart failure * ECG wide QRS and : QRS \> 120 msec in NYHA III- IV OR CLBBB or QRS \> 150 in NYHA =II * Sinus rhythm predominant rhythm (PAF not an exclusion) * All must be candidates for De novo CRT-D implantation with LV lead via transvenous approach or patients previously implanted with pacemaker or ICD with \<20% pacing over the last three months who are undergoing CRT-D upgrade. * Patient provides informed consent, tolerate a pectoral implant, agree to comply with the protocol, and maintain scheduled follow-up visits.

Exclusion criteria

* Permanent or persistent atrial fibrillation * Advanced renal disease (Cr \>=2.5 mg/dL) * Advanced comorbidities with life expectancy of \<1 year * Patients on waiting list for heart transplantation * Requiring intravenous amines (continuous or or intermittent amine drip therapy) * Severe chronic pulmonary disease (simulating heart failure) * Severe (untreated) organic mitral valve disease * Poorly treated hypertension * History of myocardial infarction \< 3 months; unstable angina \< 1m, CABG \<3 months; PCI \<3 months * Mechanical TC valve * Previously implanted CRT system * Poorly visualized cardiac chamber dimensions in an echocardiogram performed prior to enrollment - please help us define * Pregnancy or child-bearing potential in the absence of accepted forms of birth control * Concurrent enrollment in other study

Design outcomes

Primary

MeasureTime frameDescription
Demonstrating Percent reduction in left ventricular end systolic (LVESV) at 6 months compared with baseline values.within 12 month from enrollment.To show that in patients with ischemic cardiomyopathy, implantation of a CRT LV lead guided by radial strain imaging results in a significantly greater echocardiographic and clinical response to cardiac resynchronization therapy compared with conventional implantation techniques.

Secondary

MeasureTime frameDescription
Clinical ImprovementWithin 12 month from enrollmentA combined clinical event rate - change in NYHA, hospitalization for heart failure, death
Echocardiographic improvementWithin 12 month from enrollment\>15% improvement in LVESV, \>10% improvement in LVEDV, 5% absolute improvement of LVEF
Improvement in wellbeingWithin 12 month from enrollment10 point improvement in Minnesota Living with Heart Failure Questionnaire (MLWHF), 10% improvement of 6 minute walk test(6MWT)

Countries

Israel, United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026