Impact of Volume Imaging Using Diagnostic Ultrasound

Impact of Volume Imaging With Ultrasound

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01601782
Enrollment
16
Registered
2012-05-18
Start date
2009-08-31
Completion date
2010-05-31
Last updated
2018-01-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bone Injuries, Muscle Injuries, Tendon Injuries

Brief summary

Determine if volume imaging can diagnose bone, ligament, muscle injuries.

Detailed description

The investigators are attempting to determine if Volume imaging (a new type of ultrasound imaging)can accurately diagnose injuries of the muscle ligaments, tendons and bones when compared to conventional ultrasound imaging.

Interventions

PROCEDUREUltrasound Scan

Subject will be required to lie flat for no longer than 3 minutes to complete a volume imaging ultrasound scan of the injured area. Following the volume imaging scan a conventional ultrasound scan will be completed as ordered by their clinician.

DEVICEUltrasound Scan using a General Electric Ultrasound Scanner Model Logiq E9 (model name).

The subject will be required to lie flat for approximately 5 to 10 minutes to complete a conventional ultrasound scan to x-ray the muscle and tendon injuries.

Sponsors

University of Michigan
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age 18 or older * Must be scheduled to have a musculoskeletal (bone, ligament, muscle, tendon) ultrasound performed as part of their routine clinical care.

Exclusion criteria

* Unable to lie flat on ultrasound table. * Subjects under 18 years of age

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of 3D Ultrasound Scanning Expressed as Percent Correlation Between Images From Conventional Ultrasound and Volume ImagingUp to 13 minutesBoth ultrasound and volume imaging scans were done on the same day. For all scanned patients, the ultrasound technologist took a volume of images focusing where the patient had symptoms. The study PI reviewed the images, then went back in to do second scan. It took 5 to 10 minutes to complete a conventional ultrasound scan and up to 3 minutes to complete a volume imaging ultrasound scan.

Countries

United States

Participant flow

Recruitment details

Patients who are referred for an ultrasound of the extremity will be asked to participate in the study.

Participants by arm

ArmCount
Volume Imaging Scan
New type of ultrasound scan using General Electric US scanner, Model is a GE Logiq E9. Ultrasound Scan using a General Electric Ultrasound Scanner Model Logiq E9 (model name). : The subject will be required to lie flat for approximately 5 to 10 minutes to complete a conventional ultrasound scan to image the muscle and tendon injuries. Ultrasound Scan : Subject will be required to lie flat for no longer than 3 minutes to complete a volume imaging ultrasound scan of the injured area. Following the volume imaging scan a conventional ultrasound scan will be completed as ordered by their clinician.
16
Total16

Baseline characteristics

CharacteristicVolume Imaging Scan
Age, Continuous25 years
Sex: Female, Male
Female
7 Participants
Sex: Female, Male
Male
9 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
— / —
other
Total, other adverse events
0 / 16
serious
Total, serious adverse events
0 / 16

Outcome results

Primary

Accuracy of 3D Ultrasound Scanning Expressed as Percent Correlation Between Images From Conventional Ultrasound and Volume Imaging

Both ultrasound and volume imaging scans were done on the same day. For all scanned patients, the ultrasound technologist took a volume of images focusing where the patient had symptoms. The study PI reviewed the images, then went back in to do second scan. It took 5 to 10 minutes to complete a conventional ultrasound scan and up to 3 minutes to complete a volume imaging ultrasound scan.

Time frame: Up to 13 minutes

ArmMeasureValue (NUMBER)
Volume Imaging ScanAccuracy of 3D Ultrasound Scanning Expressed as Percent Correlation Between Images From Conventional Ultrasound and Volume ImagingNA percent correlation