Skip to content

Closed-loop System for Oxygen Delivery and Exercise in Chronic Obstructive Pulmonary Disease

Using a Closed-loop System for Oxygen Delivery (FreeO2) to Optimize Exercise Tolerance During Walk in Patients With COPD, Oxygen Therapy and Hypercapnia

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01575327
Acronym
FreeO2-rehab
Enrollment
15
Registered
2012-04-11
Start date
2012-07-31
Completion date
2016-06-30
Last updated
2018-03-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

COPD, Hypercapnia, Oxygen Therapy

Brief summary

The purpose of this study is to investigate the benefit of Closed-loop System for Oxygen Delivery (FreeO2) as compared with fixed oxygen flow during endurance shuttle walking test in patients with Chronic obstructive pulmonary disease (COPD), oxygen therapy and hypercapnia. The study was designed to test the following hypotheses: As compared with fixed oxygen flow, the FreeO2 Oxygen Delivery system leads to higher exercise tolerance (distance during ESWT) and lower desaturation events without increase in hypercapnia in patients with COPD, oxygen therapy and hypercapnia. As compared with fixed oxygen flow, the FreeO2 Oxygen Delivery system leads to lower dyspnea and leg fatigue scores at a given endurance time during the shuttle walking test in patients with COPD, oxygen therapy and hypercapnia. As compared with fixed oxygen flow, the FreeO2 Oxygen Delivery system leads to lower cardiac and respiratory frequencies at a given endurance time during the shuttle walking test in patients with COPD, oxygen therapy and hypercapnia.

Detailed description

Background: In spite of oxygen therapy, desaturations frequently occur during exercise in COPD patients. Although current recommendations are to add 1 L/min to the baseline oxygen flow during exertion, a new closed-loop system (FreeO2) automatically and continuously adjusts the oxygen flow to the patient's needs based on the oxygen saturation by pulse oximetry (SpO2), end-tidal CO2 (EtCO2) and respiratory rate. A preliminary study showed significant improvement in exercise tolerance in COPD patients not needing oxygen therapy. Although oxygen flow could be two fold increased during exercise, a worsening hypercapnia is plausible in severe COPD. Aim of this study is to evaluate this system during endurance shuttle walking test in COPD patients with oxygen therapy and hypercapnia. Methods: The investigators proposed to conduct a controlled, randomized cross-over study comparing the efficacy of a Closed-loop System for Oxygen Delivery (FreeO2) as compared with fixed oxygen flow during an endurance shuttle walking test in patients with COPD, oxygen therapy and hypercapnia.

Interventions

FreeO2 automatically adjusts the oxygen flow delivered to patients based on the SpO2 signal and collects the cardiorespiratory parameters

FreeO2 system does not adjust oxygen flow but collects the cardiorespiratory parameters

Sponsors

University Hospital, Grenoble
CollaboratorOTHER
AGIR à Dom
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
40 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* 40 Years and older * Patient with COPD severe to very severe requiring long-term Oxygen Therapy * Hypercapnia (PaCO2 \> 45mmHg) * Former or current smoker greater than or equal to 10 pack-years

Exclusion criteria

* Pregnant or breast-feed woman * Patients under guardianship * Imprisoned patients

Design outcomes

Primary

MeasureTime frameDescription
Change in Endurance timeDay 0 (inclusion) + 14 and D0 +21Duration during the endurance shuttle walking test

Secondary

MeasureTime frameDescription
Change in Muscle fatigue during ESWTDay 0 (inclusion) + 14 and D0 +21Visual analogic scores of leg discomfort during the endurance shuttle walking test
Change in Respiratory frequency during ESWTDay 0 (inclusion) + 14 and D0 +21Respiratory frequency measurement by the FreeO2 system during the endurance shuttle walking test
Change in PaCO2 during ESWTDay 0 (inclusion) + 14 and D0 +21EtCO2 measurement by the FreeO2 system during the endurance shuttle walking test
Change in Dyspnea during ESWTDay 0 (inclusion) + 14 and D0 +21Visual analogic scores of dyspnea during the endurance shuttle walking test
Change in Cardiac frequency during ESWTDay 0 (inclusion) + 14 and D0 +21Cardiac frequency measurement by the FreeO2 system during the endurance shuttle walking test
Change in SpO2 during ESWTDay 0 (inclusion) + 14 and D0 +21Pulse oxygen saturation during the endurance shuttle walking test
Hypercapnia level at baselineDay 0 (inclusion) - baseline evaluationBlood gases at rest

Countries

France

Outcome results

None listed