Skip to content

A Randomized Non Crossover Study of the GuardianTM Versus SupremeTM Laryngeal Mask Airway

A Randomized Non Crossover Study of the GuardianTM Versus SupremeTM Laryngeal Mask Airway

Status
Completed
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01575236
Enrollment
120
Registered
2012-04-11
Start date
2012-03-31
Completion date
2012-07-31
Last updated
2012-08-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Adverse Anesthesia Outcome

Brief summary

The investigators test the hypothesis that ease of insertion, oropharyngeal leak pressure, fiberoptic position and ease of gastric tube placement differ between the GuardianTM and the LMA SupremeTM in paralyzed, anesthetized patients.

Detailed description

The GuardianTM is a new extraglottic airway device which brings together features of both the LMA ProSealTM (high seal cuff, gastric access and bite block - to facilitate ventilation, airway protection and airway obstruction, respectively) and the LMA UniqueTM (single use - prevention of disease transmission). In the following randomized, non-crossover study, the investigators test the hypothesis that ease of insertion, oropharyngeal leak pressure, fiberoptic position and ease of gastric tube placement differ between the GuardianTM and the LMA SupremeTM in paralyzed, anesthetized patients.

Interventions

ease of insertion, oropharyngeal seal pressure, fiberoptic position, ease of ventilation, occult blood, gastric insertion

ease of insertion, oropharyngeal seal pressure, fiberoptic position, ease of ventilation, occult blood, gastric insertion

Sponsors

Medical University Innsbruck
CollaboratorOTHER
Schulthess Klinik
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* ASA 1 or 2 * Age 18-75 yr * Written informed consent

Exclusion criteria

* Difficult airway * Non fasted * BMI \> 35

Design outcomes

Primary

MeasureTime frameDescription
efficacy of oropharyngeal seal pressure5 minthis will be measured over the full range of cuff volumes (0-40 ml) and at an intracuff pressure of 60 cm H2O

Secondary

MeasureTime frameDescription
anatomic position5 minthis will be determined fiberoptically via the airway tube over the full range of cuff volumes and at an intracuff pressure of 60 cm H2O

Countries

Austria

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026