Proliferative Diabetic Retinopathy
Conditions
Keywords
Cataract, Phacoemulsification, Temperature, Vitreous
Brief summary
Temperature in the vitreous cavity decreases during vitrectomy, and the same effect is seen during an uneventful phaco surgery. Significant changes occur between the baseline temperature and after every step of the surgery.
Detailed description
A 23-gauge thermometer probe inserted prior to the beginning of the cataract surgery to measure the vitreous temperature at different stages of the procedure (capsulorrhexis, hydrodissection, phacomulsification, irrigation/aspiration and intraocular lens (IOL) implantation). Room temperature also registered during every step. At the end of the surgery, oral temperature will be measured.
Interventions
Transurgical measurement of temperature
Sponsors
Study design
Eligibility
Inclusion criteria
* Patients from the Retina department that underwent phacoemulsification and vitrectomy
Exclusion criteria
* Posterior capsule rupture
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Vitreous temperature | Every five minutes during a phacoemulsification procedure, and at every step of the surgery | Temperature of the vitreous is taken every five minutes from the start of a phacoemulsification. Also Temperature is take after every step of the surgery (capsulorhexis, hydrodissection, phacoemulsification, irrigation/aspiration, IOL implantation). |
Countries
Mexico