Skip to content

Affixing Polypropylene Mesh Using Barbed Suture (Quill™ Srs) During Laparoscopic Sacrocolpopexy Randomized Controlled Trial (Quill Lsc)

Affixing Polypropylene Mesh Using Barbed Suture (Quill™ Srs) During Laparoscopic Sacrocolpopexy Randomized Controlled Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01551992
Acronym
QUILL-LSC
Enrollment
32
Registered
2012-03-13
Start date
2010-11-30
Completion date
2014-07-31
Last updated
2014-09-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Prolapse

Keywords

Sutures, Pelvic Organ Prolapse, Sacrocolpopexy, Laparoscopy

Brief summary

1.0 STUDY OBJECTIVE 1.1 PRIMARY OBJECTIVE - To compare two methods of polypropylene mesh attachment during laparoscopic sacrocolpopexy (LSC): running technique using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA). 1.2 SECONDARY OBJECTIVE - To compare laparoscopic sacrocolpopexy anatomic failure rates at 6 months post-operative follow-up using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA). The investigators will also assess mesh erosion rates, costs, and surgeon satisfaction rates. 2.0 HYPOTHESIS 2.1 Primary: 2.1.a. Attachment of mesh using the running technique with self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) will be faster than the standard fixation interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA). 2.2 Secondary: 2.2.a. Attachment of mesh using the running technique with self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) will be less costly than the standard fixation interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA). 2.2.b. Failure rates and mesh erosion rates for each technique will be equally low. 2.2.c. Surgeons will prefer the barbed running technique over the interrupted technique based on subjective surgeon satisfaction questionnaires.

Interventions

PROCEDUREQuill suture vs. Interrupted suture

To compare two methods of polypropylene mesh attachment during laparoscopic sacrocolpopexy (LSC): running technique using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA).

Sponsors

Kaiser Permanente
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* \>18 years old * Undergoing LSC with or without other procedures for pelvic organ prolapse or incontinence * Willing to return for follow-up visits * Written informed consent obtained from each subject * Must be having a robotic assisted laparoscopic sacrocolpopexy

Exclusion criteria

* Decline to participate * Pregnant or contemplating future pregnancy * Unable to participate in the informed consent process

Design outcomes

Primary

MeasureTime frameDescription
Mesh attachment intervalIntraoperativelyTo compare two methods of polypropylene mesh attachment during laparoscopic sacrocolpopexy (LSC): running technique using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus interrupted technique using 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA)in terms of time.

Secondary

MeasureTime frameDescription
Anatomic outcomes using the two suture types6 months post-operativelyTo compare laparoscopic sacrocolpopexy anatomic failure rates at 6 months post-operative follow-up using self-anchoring 1 barbed delayed absorbable suture (Quill™ SRS, Angiotech Pharmaceuticals, Inc. Vancouver, Canada) versus 0 non-barbed delayed absorbable suture (PDS II™, Ethicon, Somerville, NJ, USA). We will also assess mesh erosion rates, costs, and surgeon satisfaction rates.