Skip to content

Bone Quality by vQCT and HR-pQCT:Translation to Multi-center Clinical Research

Bone Quality by vQCT and HR-pQCT:Translation to Multi-center Clinical Research

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01544660
Acronym
Interscanner
Enrollment
60
Registered
2012-03-06
Start date
2012-04-30
Completion date
2014-03-31
Last updated
2014-04-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bone Mineral Density

Keywords

spine and hip scan, BMD

Brief summary

Our overarching aim is to set up a procedural, analytic and developmental framework to establish CT of the central and peripheral skeleton as a clinically useful biomarker for skeletal strength in the clinical research and ultimately in the clinical setting. To accomplish this, the investigators will develop and validate phantoms and scanning procedures to standardize strength and structure measurements between different vQCT scanners and develop standardized acquisition, analytical, and quality control techniques for HR-pQCT with an emphasis on optimization for multi-center studies.

Detailed description

The investigators will develop new calibration phantoms to address inter and intra scanner variability in vQCT and HRpQCT. Phantom sets to evaluate inter-scanner disparity and determine corrections to apply to in vivo scan data in the multi-center settings. These methods will be validated in a multi-center phantom study and in a 120 patients

Interventions

None listed

Sponsors

Mayo Clinic
CollaboratorOTHER
University of California, San Francisco
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
65 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

* Healthy men and women * must be able to lie down on bed

Exclusion criteria

* on wheel chair * age above 80 years 0r less than 65 years

Design outcomes

Primary

MeasureTime frameDescription
Develop and Validate phantoms and scanning procedures to standardize strength and structure measurements between different scanners.one visit lasting 3 hours for each subject.Correction of the in vivo images using the proposed inter-scanner calibration approaches will improve the quality of multi-site data by reducing the variability in CT structure and strength measures. To study the Multi-center standardization of vQCT and HR-pQCT imaging we will develop new calibration phantoms to address inter and intra-scanner variability in vQCT and HRpQCT bone strength and structure estimates.

Secondary

MeasureTime frameDescription
Development of open-source image analysis metric for vQCTTime frame will be 3 hours for a visitTo provide standardized analysis of future clinical studies and retrospective analysis of past trials, we will develop a set of image analysis metrics for vQCT (trabecular, cortical and integral BMD, cortical thickness, cross-sectional areas, axial and bending strength estimates). These metrics will be made available to the community in an open source format, allowing them to be incorporated into commercial software platforms at the discretion of the manufacturer, incorporation as a plug-in for NIH supported programs such as MIPAV.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026