Skip to content

Ultrasound and Paediatric Endotracheal Tube Size

Role of Ultrasound Compared to Age-related Formulas for Uncuffed Endotracheal Intubation in a Paediatric Population

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01535300
Enrollment
50
Registered
2012-02-17
Start date
2010-08-31
Completion date
2010-10-31
Last updated
2012-02-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Uncuffed Endotracheal Intubation

Keywords

Ultrasound, Minimal transverse tracheal diameter, Endotracheal tube size, Paediatric age-based formulas, Sonographic measurement of the trachea

Brief summary

The aim of the present study was to evaluate the role of ultrasound in paediatric patients to compare the correct size of an uncuffed endotracheal tube (ETT) with the minimal transverse tracheal diameter (MTTD) measured by ultrasound and with tube size predicted by different age-related formulas. The investigators hypothesize that a prediction of pediatric ETT is possible with the ultrasonographic measurement of the MTTD.

Interventions

PROCEDUREUltrasonography of the trachea

Ultrasonographic measurement of the minimal transverse tracheal diameter

Sponsors

SonoSite, Inc.
CollaboratorINDUSTRY
Heidelberg University
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
No minimum to 5 Years
Healthy volunteers
No

Inclusion criteria

* written informed consent * children \<= 5 years of age * elective surgery requiring endotracheal intubation

Exclusion criteria

* missing informed consent * allergy to ultrasound gel

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026