Rotational Malalignment of the Lower Extremity
Conditions
Keywords
MRI, Lower Extremity Rotational, Femoral Version, Tibial Torsion
Brief summary
Determining the investigators ability to accurately assess rotational malalignment clinically compared to imaging.
Detailed description
The objectives of this study are 1) to assess the inter/intra-observer reliability of rotational measurements on axial MRI images and 2) determine the correlation between clinical and MRI measures of femoral version and tibial torsion. The investigators will use previously obtained MRI images to retrospectively calculate the inter-observer and intra-observer reliability of our measurements. Participating physicians will undergo training to standardize measurement technique. Five orthopaedic surgeons and one radiologist will perform the measurement to calculate inter-observer reliability. To asses intra-observer reliability, repeat measurements will be performed by the same physicians at a later date (at least 2 weeks). The physicians will be blinded to previous results when performing the second set of measurements. A standardized rotational profile will be performed on all patients presenting to the investigators with patellofemoral complaints or rotational abnormalities warranting intervention. Internal and external hip rotation will be measured in the prone and supine positions. Tibial torsion will be assessed with the thigh-foot axis in the prone and sitting positions. Investigators will participate in a formal training session prior to data collection to normalize measurements. Each study participant will undergo MRI imaging of the femur and tibia.
Interventions
None listed
Sponsors
Study design
Eligibility
Inclusion criteria
Retrospective: * Prior study MRI images available in the University PACS system * Prior study MRI images obtained at PCMC and uploaded into the OsiriX software (OsiriX is a software program compatible with multiple imaging formats that has easily adaptable measurement tools) * We will search our imaging database from 2009 to current. Included will be all gun site MRI studies obtained at PCMC or the UOC for evaluation of rotational profile. We will exclude any study in which images are not sufficient to obtain all of the required measurements needed for our study. A preliminary review of the imaging database has identified 42 potential studies. Our power analysis calls for 15 patients to be included to obtain a 95% confidence interval. Inclusion Criteria: Prospective: * All patients of the investigating physicians, male and female, between the ages of 8 and 30 presenting with complaints of patellofemoral pain/instability or rotational abnormality * All patients with neuromuscular disease, including cerebral palsy
Exclusion criteria
Retrospective: * Any patients with imaging studies insufficient to provide all of the required measurements and any patient previously surgically treated for rotational malalignment
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| To assess the inter/intra-observer reliability of rotational measurements on axial MRI images | 4 years |
Secondary
| Measure | Time frame |
|---|---|
| To determine the correlation between clinical and MRI measures of femoral version and tibial torsion. | 4 years |
Countries
United States