Skip to content

Quality of Quality Data

Quality of Quality Data - A Retrospective Study on Routine Quality Data Reporting in Anesthesia

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01524484
Acronym
QoQ
Enrollment
255
Registered
2012-02-02
Start date
2011-11-30
Completion date
2012-04-30
Last updated
2014-10-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anesthesia

Keywords

Data quality, Anesthesia, Quality assurance

Brief summary

Data on quality of clinical anesthesia are important for the improvement of both quality and patient safety in this field. Routine quality data are often collected by professionals busy with patient care. This study examines the reliability of routinely collected quality data by comparing the electronic anesthesia record with the respective reports on quality-indicating events, i.e. whether events during the anesthetic (e.g., drop of blood pressure, irregular heart rhythm, and others) were actually reported or not. Additionally, interviews with reporting staff (physicians and nurses) are performed to gain insight in possible obstacles to reporting during the working process.

Detailed description

Reliable quality data are an important basis for attempts to improve quality and safety of patient care. For anesthetic practice in Switzerland, an Absolute Minimal Data Set (AMDS) of preoperative patient characteristics and intra- and postoperative quality indicators is provided by the Institute of Social and Preventive Medicine (IUMSP, University of Lausanne) in cooperation with the Swiss Society of Anaesthesiology and Reanimation (SGAR-SSAR). Data are electronically forwarded by the participating institutions to IUMSP, whereas primary collection can be achieved by traditional paper records or electronic records as part of anesthesia information management systems (AIMS). In the investigator's institution, physician and nurse anesthetists are supposed to use a window in the electronic anesthesia record for this purpose. This form should be completed at the end of each case. If an event according to the AMDS definitions occurs at least once during anesthesia, the respective box (e.g., intraoperative hypotension) should be ticked in the form. The anesthesia record cannot be closed unless the quality form is filled, which can notably be done even in advance on the quick by ticking no events. Considering the numerous duties of anesthesia staff at the end of a case, the investigators questioned the reliability of data generated during this busy phase. A pilot study of 50 consecutive unselected cases of the year 2010 revealed a low rate of reporting (10.8%) of selected perioperative events related to anesthesia (specifically: hypotensive, hypertensive, bradycardic, tachycardic, and hypoxemic episodes). Consequently, the current extensive study with more representative sample size was initiated. To gain insight into possible causes (among others: time pressure, unclear definitions, fear of litigation), interviews with anesthesia staff are performed and will hopefully provide a basis for possible improvements. For the time being and considering the common nature of possible causes, the investigators suspect that their results may not be specific for their institution. The incidence of perioperative events may be grossly underestimated if the process of data collection is not properly designed and monitored.

Interventions

None listed

Sponsors

University of Zurich
CollaboratorOTHER
University of Freiburg
CollaboratorOTHER
Johannes Wacker, MD
Lead SponsorOTHER

Study design

Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* 50 consecutive cases for pilot study; * 200 anesthetic records of the year 2010 chosen as a random sample. * all staff entering the quality data into the electronic anesthesia record (physicians, nurses)

Exclusion criteria

* participation of staff in this study, * participation in quality data processing or assessment, * longterm leave precluding the interview

Design outcomes

Primary

MeasureTime frameDescription
Event reporting rateOutcome measure is assessed at the end of each included anesthetic. Event reporting rate comprises reporting rate of defined events occurring during the given anesthetic. Durations of anesthetics are approximately between 0.5 and 5 hours.For defined events (hypotensive, hypertensive, bradycardic, tachycardic, and hypoxemic episodes), occurrence documented in the electronic anesthesia record is compared with their actual reporting in the reporting section of the record. From this, reporting rate is calculated for the various event types.

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 18, 2026